• Title/Summary/Keyword: standard regulations

Search Result 708, Processing Time 0.028 seconds

Development of the Compressed Packer Grouting Device for Preventing the Inflow of Polluted Groundwater (오염지하수 유입방지를 위한 압축패커 그라우팅 장치 개발)

  • Cho, Heuy-Nam;Choi, Sang-Il
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.433-439
    • /
    • 2009
  • The compressed packer device is designed to improve the underground contamination prevention facilities of ground water wells. As for the device, the installation is simple because of the safety lock device and the compression of the casing are simple the installation is simple. There is no leakage of ground water because the pressure resistance with $4.5\;kg/cm^2$ makes it equipped with the watertightness The single casing is installed and the reaming for grouting is possible with 300 mm excavation so that installation cost can be saved. Silicon rubber is used for the compressed packer so that the extension rate is 590%. In terms of environmental pollution, it is an environmental friendly product which does not contain harmful ingredients such as Pb, Cd, and phenol. below the standard or undetectable level Furthermore, the installation costs are 35 to 62% or lower than the conventional grouting construction method and are 87% or lower than the expansion packer construction method, the new environmental technology No.47 Also, the device is designed to meet the relevant regulations such as Rules on Preserving the Ground Water Quality, The Standard on Jeju Island Ground Water Development and Facility Installation and Management, and The Plan and Guideline on Operating and Managing the Small-Scale Tap Water Facilities of Ministry of Environment and Ministry of Food, Agriculture, Forestry and Fisheries.

Improvement and Application of Assessment Criteria on Disease Control Level in Olive Flounder Aquaculture Farms (넙치 양식장의 질병관리등급 평가기준 개선 및 적용)

  • CHO, Miyoung;HA, Heon-Ju;MIN, Jin-Gi;KIM, Tae-Jin;JEE, Bo-Young;PARK, Shin-Hoo;HWANG, Seong-Don;KIM, Kwang-il;JANG, Yeounghwan;PARK, Myoung-Ae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1646-1655
    • /
    • 2015
  • Korean government has issued the ratings standard for disease control of aquaculture farms according to the Aquatic Life Disease Control Act in 2008. There are five rating criteria within the enforcement regulations; period of disease free, performance of disinfection, environmental and hygienic management, keeping record of trade and sales, completion of education for disease control. There are no application has been applied on the basis of the rating criteria so far because detailed subcriteria and scoring indicators has not established for assessment process. In order to apply the ratings standard for disease control, we set up the subcriteria and new scoring for rating disease control level based on legal criteria in this study. This study was conducted on 90 targeted olive flounder farms in Jeju. The result of disease control level assessment on olive flounder aquaculture farms show the overall average of Jeju-do was 72.9 points and differed depending on the district; 74.7 in Jeju-si and 71.1 in Seogwipo-si, respectively. The Spearman correlation of each evaluation index show the disease control level score was correlated highly with the performance of disinfection(R=0.715, p<0.01), and environmental and hygienic management(R=0.661, p<0.01). The result of correlation analysis show that there is the highest correlation between the aquaculture farm status and the total mortality(R= -0.618, p<0.01). The reliability of the results are considered to be accurate in the Cronbach's alpha value of 0.727.

Structural Stiffness Analysis on Doors having Pyramidal Truss Cores in an Urban Transit Vehicle (피라미드 트러스 심재를 채용한 도시철도차량 출입문의 구조강성평가)

  • Lim, Jae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.697-702
    • /
    • 2017
  • A preliminary study was carried out to investigate the feasibility of replacing honeycomb cores with pyramidal truss cores in the doors of urban transit railway vehicles. The doors in current operation are sandwich structures comprising a honeycomb core and reinforcements between two facesheets. The structural requirements of doors for urban transit vehicle are specified in the KRS and KRT and standards, according to which the deflections from three-point bending tests must be limited. To this end, two types of pyramidal truss cores with equivalent mass to a honeycomb core were designed. The structural stiffness of doors with pyramidal truss cores and honeycomb cores were numerically calculated via finite element analysis. The three-point bending models were constructed and simulated, and then the calculated deflections were compared with the requirements specified in the regulations. The results show that doors with pyramidal truss cores satisfied the stiffness requirements, although their deflections were 2.5% larger than that of the honeycomb cores. Therefore, the pyramidal truss cores could replace the aluminum honeycomb cores, and their multi-functional capability could be exploited.

Microbiological Quality of the Shellfish-growing Waters and Mussels in Changseon, Namhae, Korea (남해 창선해역의 해수 및 진주담치의 위생학적 안전성 평가)

  • Yoo, Hyun-Duk;Ha, Kwang-Soo;Shim, Kil-Bo;Kang, Jin Yeong;Lee, Tae-Seek;Kim, Ji-Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.4
    • /
    • pp.298-306
    • /
    • 2010
  • A sanitary survey was conducted to evaluate the water quality and mussel (Mytilus edulis) conditions of two administrative shellfish growing waters: those designated as shellfish growing water for export, and adjacent waters on the east coast of Changseon Island, Namhae, Korea. In all, 1,656 seawater and 166 mussel samples were collected at 46 stations for seawater and five stations for the shellfish from January 2007 to December 2009. Both seawater and mussels were examined for total coliforms and fecal coliforms. The standard plate count and most probable number of Escherichia coli were also determined for the shellfish samples. The range of the geometric means and the estimated 90th percentiles of fecal coliform for seawater samples at each station were <1.8-4.1 MPN/100 mL and <1.8-22.3 MPN/100 mL, respectively. The sanitary conditions for both shellfish growing areas, the designated shellfish growing area and adjacent area in Changseon, met the 'Approved area' criteria of the United States National Shellfish Sanitation Program. The range of E. coli detected in mussels in these areas was <20-500 MPN/100 g; and only 3 of 166 samples exceeded 230 MPN/100 g, the European standard for the consumption of raw bivalves. Therefore, the mussel farms in the Changseon area are classified as 'Class A' according to criteria set in European Community regulations. However, the levels of E. coli in mussels in parts of the designated shellfish growing area and adjacent area exceeded the bacterial limits after rainfall exceeding 45 mm. Further studies are needed to fully define the conditions leading to a temporary closure to harvest after a rainfall event.

A Study on the Development of the National Assembly Archives and Records Integrated Management System (국회기록정보 통합관리시스템 개발 방향에 관한 연구)

  • Kim, Jang-Hwan;Lee, Eun Byol
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.15 no.2
    • /
    • pp.103-136
    • /
    • 2015
  • The National Assembly Archives of the Republic of Korea has been using the National Assembly Archives and Records Management System, which added some archival function to the Standard Records Management System that they had previously developed. However, the Standard Records Management System has limits in order to reflect all the business functions of the National Assembly Archives, which also acts as an archival institution, because the system had been developed and distributed to perform the function of a records center. Moreover, the current National Assembly Archives and Records Management System focuses on the management of official records transferred in accordance with the regulations. For this reason, it is difficult to register and manage various record types such as records of the members of the National Assembly (related to legislative activities), oral history collected from the National Assembly leader, audiovisual records of proceedings, and so on. As such, this study analyzed the problems of the current National Assembly Archives and Records Management System and conducted case studies of the systems in the National Archives, the Presidential Archives, Changwon City, and the Cultural Heritage Administration. Through this research, it proposed that system functions, metadata, the target system of the National Assembly Archives, and the Records Integrated Management System need a development plan.

A study on the Plan Modular Establishment for the Development of Wooden Dwelling Model - Focused on the Post & Beam Structure - (목조주택 모형개발을 위한 평면모듈 설정에 대한 연구 - 기둥-보 방식 구조를 중심으로 -)

  • Kang, Man-Ho;Joo, Seok-Joong;Kim, Jae-Deok
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.141-148
    • /
    • 2007
  • In this research, to develope wooden house model with post & beam structure which is commensurate with domestic environment, we analyzed the size and module of a unit space and space organization of existing habitation, then, based on the result, we tried to suggest general wood house modules. For this, we investigated 98 floor plans for 30 pyeong apartment in Seoul, Gyounggi-do, Gwangju, and Jeolla-do. The results are showed as follows. 1) It has shown that 7 posts distances are available in 2 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, and 4.8 m. 2) It has shown that 8 posts distances are available in 3 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, 4.8 m, and 5.1 m. It was concluded as follows, applying the standard of regulations of horizontal modular coordination design, from $\ulcorner$the standard of modular coordination design in architecture(KSF 1525)$\lrcorner$. 1) The available widths are 3.0 m, 3.3 m, 3.6 m, 4.2 m, and 4.8 m, and the available depths are 3.0 m, 3.3 m, 3.6 m, and 4.2 m. 2) To guarantee a space through post module of a room combination, we can use a module of 3.6 m, 4.2 m, 4.8 m except 3.0 m, 3.3 m among available modules. The module investigated in post & beam structure wooden house is applied in basic 6 floor plans as follows. 1) When organize the room on the basis of tile module of 3.6 m, 4.2 m, it was possible to organize the floor plan. 2) After arranging main room, making practical application of variableness which is advantage of post & beam structure, putting to practical use of extra space that becomes the combination of atypical room such as kitchen, dining room, and bathroom, it was possible to organize the floor plan of the residence. 3) It is possible to organize whole rooms through the plan module from 3.6 m to 4.2 m, that decides the floor plan of a wooden house.

A Study on the Important Clause of International Sales Contract (국제물품매매계약(國際物品賣買契約)의 주요 조항(條項)에 관한 연구(硏究))

  • Park, Nam-Kyu
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.18
    • /
    • pp.27-62
    • /
    • 2002
  • The international sale contract is the central contracts in export-import transactions. A good sale contract or set of general conditions of sale will cover all the principal elements of the transaction, so that uncertainties are avoided. The parties' respective duties as concern the payment mechanism, transport contract and insurance responsibilities, inter alia, will all be clearly detailed in the contract. The following key clauses should be included in international contracts of sale and general conditions of sale: ${\bullet}$ preamble ${\bullet}$ identification of parties ${\bullet}$ description of goods ${\bullet}$ price and payment conditions ${\bullet}$ delivery periods and conditions ${\bullet}$ inspection of the goods - obligations and limitations ${\bullet}$ quantity or quality variations in the products delivered ${\bullet}$ reservation of title and passing of property rights ${\bullet}$ transfer of risk - how accomplished ${\bullet}$ seller's warranties and buyer's complaints ${\bullet}$ assignment of rights ${\bullet}$ force majeure clause and hardship clause ${\bullet}$ requirement that amendments and modifications be in writing ${\bullet}$ choice of law ${\bullet}$ choice of dispute resolution mechanism Under most systems of law, a party can be excused from a failure to perform a contract obligation which is caused by the intervention of a totally unforeseeable event, such as the outbreak of war, or an act of God such as an earthquake or hurricane. Under the American commercial code (UCC) the standard for this relief is one of commercial impracticability. In contrast, many civil law jurisdictions apply the term force majeure to this problem. Under CISG, the standard is based on the concept of impediments to performance. Because of the differences between these standards, parties might be well advised to draft their own force majeure, hardship, or excusable delays clause. The ICC publication, "Force Majeure and Hardship" provides a sample force majeure clause which can be incorporated by reference, as well as a hardship clause which must be expressly integrated in the contract. In addition, the ICC Model provides a similar, somewhat more concise formulation of a force majeure clause. When the seller wishes to devise his own excusable delays clause, he will seek to anticipate in its provision such potential difficulties as those related to obtaining government authorisations, changes in customs duties or regulations, drastic fluctuations in labour, materials, energy, or transportation prices, etc.

  • PDF

Analysis of the Effect on the Location Evaluation of Golf Course according to the Unit Grid Size applied in the Slope Analysis(In flank of Environment) (경사도 분석에 적용하는 단위격자크기가 골프장의 입지 평가에 미치는 영향 분석(환경적 측면에서))

  • Um, Dae Yong;Lee, Beung Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.5
    • /
    • pp.467-475
    • /
    • 2012
  • In this study, the problems were analyzed that derived a different position evaluation results depending on the unit grid size that are applied to the terrain slope analysis conducted to assess the its position and environmental impacts in the prior environment reviewing process of golf course construction projects. For this purpose, the unit grid size were analyzed that can precisely reflect a actual terrain by analyzing the change of a slope percentage according to the change of unit grid size about 12 golf courses is currently in progress of construction work through the environmental consultation or ongoing consultation. And the consultation availability of environmental assessment was reverified by applying the unit grid size derived through this study about a study golf course. In the result of study, the bigger grid size for slope analysis is set, the greatly gradient is changed and the slope ratio of the higher elevation was lowly evaluated in comparison with actual terrain. The analytical result that most closely match the actual terrain was extracted in the case applied $5m{\times}5m$ of the unit grid sizes setting in this study. So, we proposed this study results to the ministry of environment and could be amended the unit grid size of $5m{\times}5m$ as standard for the analysis of slope. Also, if new grid size for site evaluation is applied to the study sites, 4 sites exceed the standard suggested the existing regulations and they are not proper as golf course site in flank of environment.

The Research of Improvement and Development Process for protection in Korea Private Security (한국 신변보호업의 발전과정과 개선방안 연구)

  • Park, Jang Gyu;Kim, Nam Joong
    • Convergence Security Journal
    • /
    • v.13 no.2
    • /
    • pp.33-43
    • /
    • 2013
  • The Private Security Industry of Korea began after served security service for the United States army of 8 division. The industry grew up after establish private security regulation on December 31th of 1976. Early 1980's the industry was accelerated from bringing technical knowledge of developed nations rapidly. Also, private security was gotten into the spotlight by one of futurity industry instead public security after companies performed 86 Asian game and 88 Seoul Olympic successfully. Therefore, the industry became to increase qualitatively and quantitatively. From late 1990's the private security regulations were revised fifteen times and created about education system, bodyguard, and leader of security. 3,836 private companies and 150,030 private guards had operated until 2012. However, some of companies received administrative measure, because of the companies ran immorally. The minor companies are continuously closed down from the leader's inefficient operation. Approval standard of establishment has imperfect law. Solutions of problems are to provide high quality service, to expand company affairs, to attract specific customers through efficiency expert, to change standard of leader of security guards, to establish security education institution through the government and to intensify requirements to establish the company.

Configuration of Test Field for Introduction of IEC 60364-4-44 to Domestic System (IEC 60364-4-44의 국내 도입을 위한 실증시험장 구성)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong;Jung, Dong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.731-732
    • /
    • 2007
  • This paper presents the final configuration of test field and test items for the application of IEC 60364-4-44 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, domestic electric power distribution system is based on multi-grounding system different from European system. Therefore, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a national standard. The authors with KEA(Korea Electric Association) carried out a project on the application of IEC 60364-4-44 to Korean electrical installations of buildings sponsored by Korean ministry of commerce, industry and energy for three years(2004.4.1$\sim$2007.3.31). The test field is established in K.E.R.I.(Korea Electrotechnology Research Institute), which is the purpose of evaluating the formula to calculate touch voltage and stress voltage in the IEC standards. This paper presents some considerations and final configuration of test field to evaluate and introduce the IEC 60364-4-44 applicable to domestic rule for the protection against ground fault.

  • PDF