• Title/Summary/Keyword: standard operating procedure

Search Result 122, Processing Time 0.027 seconds

Study of Developing SOP for Extracting Stable Vocal Features for Accurate Diagnosis (음성의 안정적 변수 추출을 위한 SOP 개발 연구)

  • Kim, Keun-Ho;Jang, Jun-Su;Kim, Young-Su;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.6
    • /
    • pp.1108-1112
    • /
    • 2011
  • Voice can be widely used to classify the four constitution types and to recognize one's health condition from extracting meaningful features as physical quantity in traditional Korean medicine or Western medicine. In this paper, we proposed the method to update the standard operating procedure (SOP) to acquire and record voices for extracting stable vocal features since they are sensitive to the variation of a subject's utterance. At first, we obtained pitch frequencies from vowels and the sentence and intensity form the sentence as features with voices acquired under subjects' utterance conditions and then the deviation ratios of features from median values according to the utterance conditions were obtained and the condition to minimize the ratio was selected as a new SOP. As a result, we decided the SOP for a subject to utter vowels with the length of 2s~1s and sentences with over 2s interval between them after practice, in consideration of the deviation and qualitative requirements. Stable voice features obtained from updated SOP produce accurate diagnosis, which will be developed and simplified for using in the u-Healthcare system of personalized medicine.

Development of Portable Calibration System for Non-Contact Water Meters (비접촉식 수위계를 위한 이동형 교정시스템 개발)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.9
    • /
    • pp.1808-1815
    • /
    • 2016
  • Stable operation of the dam and the river is directly related to the life and property of citizens, and hydrological observation data reliability is essential to the safety against disaster. Even though real-time data acquisition with high accuracy is needed for scientific and reliable water resources management, currently operating water gauges installed on the upper and down stream of dams or rivers are not easy to be calibrated or corrected on site to ensure higher reliability. K-water Institute has been operating an international accredited calibration laboratory for flows meters, rainfall and water gauges. Rainfall gauges are calibrated in the fixed standard room or on-site. However, due to the absence of on-site calibration procedure and system, on-site calibration for the water gauges are performed by an external agency. Therefore, a development of standard calibration procedure and system for on-site calibration of water gauges is needed to improve the reliability of observed hydrological data.

Development of Virtual Reality Program for Safety Improvement of Hydrogen Fueling Station (수소충전소의 안전성 향상을 위한 버츄얼리얼리티 프로그램 개발)

  • Kim, Eun-Jung;Kim, Young-Gyu;Moon, Il
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.29-33
    • /
    • 2008
  • The focus of this study is to develop a virtual reality program for safe training and virtual reality of hydrogen station. This programme consists of 4 modules such as hydrogen and safety module, hydrogen station module, hypothetical experience module, and accident scenarios module for hydrogen experts. User can experience with principles and operation condition and collect the information of hydrogen station by this programme and can simultaneously study the probable scenarios, emergency response plan/standard operating procedure about hydrogen stations. It makes it possible to educate and safety publicity for the trainee. This virtual reality program will be expected to be helpful for hydrogen station's construction propagation and technology development which is essential for hydrogen energy induction.

  • PDF

Evaluation of Single Point Vulnerability on Korean Standard Nuclear Power Plants (국내 표준형 원전의 단일 고장 취약성(SPV) 평가)

  • Chi, Moon-Goo;Kim, Myung-Su
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.685-686
    • /
    • 2008
  • For the purpose of reducing the plant trip/transient by the failure of a single component during plant operation or maintenance, the list of critical components with Single Point Vulnerability (SPV) on KSNP (Korean Standard Nuclear Power Plant), the standardized methodology of SPV evaluation and the plan to improve reliability of the equipment have been established. In addition, SPV component lists for the other domestic operating Nuclear Power Plants have been made, and the proper procedure for SPV management will be developed.

  • PDF

Lightweight Energy IoT Standard Protocol and Test Certification Procedure (에너지 IoT 표준 프로토콜 경량화 및 시험인증절차에 관한 연구)

  • Park, Myunghye;Kim, Younghyun;Myoung, Nogil;Kang, Sukyung;Eun, Changsoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.129-135
    • /
    • 2020
  • The standardization of e-IoT (energy Internet of Things) communication and service, which is the energy field of energy, is to define the standard model and to demonstrate the practical model in order to take the lead and occupy the market where new market is created with the latest technology. In particular, detailed technical specifications are defined for developing a framework for IoT technology, the foundation technology of the 4th Industrial Revolution, securing interoperability through standardization, and operating a standard platform. In this paper, we propose a method for e-IoT standard protocol lightening and test certification procedure. The proposed method provides a product implementation method that can solve the problem of low power issue of e-IoT product in the future.

New Technical Tip for Anterior Cervical Plating : Make Hole First and Choose the Proper Plate Size Later

  • Park, Jeong-Yoon;Zhang, Ho-Yeol;Oh, Min-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.212-216
    • /
    • 2011
  • Objective : It is well known that plate-to-disc distance (POD) is closely related to adjacent-level ossification following anterior cervical plate placement. The study was undertaken to compare the outcomes of two different anterior cervical plating methods for degenerative cervical condition. Specifically, the new method involves making holes for plate screws first with an air drill and then choosing a plate size. The other method was standard, that is, decide on the plate size first, locate the plate on the anterior vertebral body, and then drilling the screw holes. Our hypothesis was that the new technical tip may increase POD as compared with the standard anterior cervical plating procedure. Methods : We retrospectively reviewed 49 patients who had a solid fusion after anterior cervical arthrodesis with a plate for the treatment of cervical disc degeneration. Twenty-three patients underwent the new anterior cervical plating technique (Group A) and 26 patients underwent the standard technique (Group B). POD and ratios between POD to anterior body heights (ABH) were measured using postoperative lateral radiographs. In addition, operating times and clinical results were reviewed in all cases. Results : The mean durations of follow-up were $16.42{\pm}5.99$ (Group A) and $19.83{\pm}6.71$ (Group B) months, range 12 to 35 months. Of these parameters mentioned above, cephalad POD (5.43 versus 3.46 mm, p=0.005) and cephalad POD/ABH (0.36 versus 0.23, p=0.004) were significantly greater in the Group A, whereas operation time for two segment arthrodesis (141.9 versus 170.6 minutes, p=0.047) was significantly lower in the Group A. There were no significant difference between the two groups in caudal POD (5.92 versus 5.06 mm), caudal POO/ABH (0.37 versus 0.32) and clinical results. Conclusion : The new anterior cervical plating method represents an improvement over the standard method in terms of cephalad plate-to-disc distance and operating time.

A Study on The Awareness of Standard Operating Procedure For The Preparation in Landslide (산사태 대비 SOP에 대한 의식조사 연구)

  • Koo, WonHoi;Shin, HoJoon;Woo, ChoongShik;Baek, MinHo
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.503-510
    • /
    • 2013
  • Recently, localized heavy rain is increased by climatic changes and landslide is increased. Also, because of landslide occurred in urban area, life and property damages are increased. Therefore, standard operation procedure of disasters should be established by steps and institutions so as to respond landslide. This thesis investigated application of current disaster manual so as to write SOP of landslide for disaster prevention related experts and accepted opinion for responding necessaries by using landslide SOP and important matters by step of disaster management. As the result of investigation, application of manual was low during the current response to disasters and application was the highest in responding step among the steps of disaster management. In case of landslide, they responded that response with SOP is necessary. During the organization of landslide SOP, they responded that training and education for landslide disaster are important at the step of prevention, conduction of landslide disaster broadcasting and provision of information are important at the step of preparation, guidance for evasion and behavior methods is important at the step of response and investigation of landslide disaster damages and reflection of record and evaluation are important at the step of recovery. In addition, for the requests for landslide SOP application, there was an importance of secondary factors such as expansion of professional manpower, strengthening of law and institution, education and training for SOP acquisition, etc.

SSOP Program Development for HACCP Application in Fresh Raw Fish Manufacturing (싱싱회류 생산업체의 HACCP 적용을 지원하기 위한 SSOP Program 개발과 성과)

  • 박완희;이성학;정덕화
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.2
    • /
    • pp.84-96
    • /
    • 2004
  • This study aims at developing an easily-applicable Sanitation Standard Operating Procedure(SSOP) program for Fresh raw-fish manufacturing. It compares the sanitation inspection results of SSOP-program-applied procedure and non-applied procedure. The samplings for bacteriological examination were collected from the touching surface of food and from the personal workers. The sanitation status was recorded in the check-up list. The results were statistically analyzed to ascertain the efficiency of the SSOP program. The present official KFDA check-up list for sanitation inspection is composed of 51 items. Each item is judged to be fit or unfit to the standards. When the unfit items are more than 6, the work-place is judged to be insanitary. But in this study, the results of sanitation inspection are scaled in points in the 70% allotment, and the results of bacteriological examination are scaled in points in 30%, totaling 100%. Below 60 scores are judged to be insanitary and administratively punished; 61-75 scores are judged to be average; 76-85 good; above 86 excellent. The sanitation inspection scores by the improved check-up list went up by two grades from 71.8 (before SSOP program) to 88.6 (after SSOP program). The results of bacteriological examination also improved from 57.5 to 98.2. The total scores of both results converted in the allotment of 70% and 30% also showed an improvement by two grades from 66.4 (before SSOP program) to 93.4 (after SSOP program). The above results show that the manufacturers participated in this study are following the 8 essential sanitary procedures which are needed to anchor the HACCP system.

Safety Management for MR-Guided Interventions

  • Cherkashin, Mikhail;Berezina, Natalia;Serov, Alexey;Fedorov, Artem;Andreev, Georgy;Kuplevatsky, Vladymir
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.3
    • /
    • pp.152-157
    • /
    • 2016
  • Purpose: Operating room management is the serious and complex task for hospital managers and the common approach is to develop relevant standard operational procedures. From patient and staff safety perspective, operating room management should be well-studied and hospital should identify and address any potential risks. Simultaneous usage of different imaging and less-invasive treatment technologies demands strong management control. Materials and Methods: We have formed the multidisciplinary expert panel (surgeons, anesthesiologists, radiologists, healthcare managers etc.) for hybrid theater management standard operational procedure development. On the first stage the general concept of hybrid room design and patient routing was developed. The second stage included the technical details discussion. For patient safety improvement we modified the Surgical Safety Check-list in accordance with potential MRI-related safety challenges and concerns. Results: WHO Surgical Safety Checklist is a simple and easy-to use tool which includes three blocks of question (grouped by the surgery process). We have developed two additional blocks of questions for the intraoperative magnetic resonance investigation. It is very important to have a special detailed routing with a strong control of ferromagnetic devices and anesthesiology care. Conclusion: High-energy MRI (1.5-3.0T) is characterized by potential influence on patient and staff safety in case of hybrid surgery. It is obvious to have a strong managerial control of ferromagnetic devices and anesthesiology care. Surgical Safety Checklist is the validated tool for improving patient safety. Modification and customization of this check-list potentially provides the opportunity for surgery processes improving.

The Effect of NaOH treatment-Citric acid neutralization of Korean Standard Operating Procedure (SOP) on Physicochemical Compositions of Domestic Swine Excrement for the Connection to Thermophilic Aerobic Oxidation (TAO) (구제역 긴급행동지침(SOP)상의 화학처리방법으로 처리된 양돈분뇨의 고온호기산화공정 적용 연구)

  • Kim, Ha-Je;Kim, Soo-Ryang;Hong, In-Gi;Jeon, Sang-Jun;Kim, Cho-Rong;Jung, Gwang-Hwa;Han, Ho;Kim, Dong-Kyun;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.19 no.2
    • /
    • pp.81-88
    • /
    • 2013
  • We planned to study how the chemical disposal designed by SOP can affect on physicochemical compositions of the livestock excrement. According to Livestock Manure Management Scheme, we experimented in two steps; the first step, NaOH treatment-Citric acid neutralization, and then the second procedure, Thermophilic Aerobic Oxidation (TAO) system. Physicochemical compositions of the 3-days-old samples after NaOH treatment were pH 10.31, EC 24.54 mS/cm, SCOD 3,022 mg/L, T-N 4,315 mg/L, $NH{_4}^+-N$ 1,960 mg/L, and not detected E. coli.. And those of one-day-old samples after citric acid neutralization were pH 7.36, EC 32.89 mS/cm, $SCOD_{Mn}$ 12,733 mg/L, T-N 4,787 mg/L, $NH{_4}^+-N$ 2,450 mg/L, and E. coli. not detected. In contrast, the physicochemical compositions of the treatment plots after the second treatment with TAO system (72hr) were pH 9.42 EC 24.21 mS/cm, $SCOD_{Mn}$ 3,660 mg/L, T-N 3,616 mg/L, $NH{_4}^+-N$ 1,190 mg/L, and no detection of E. coli.