• Title/Summary/Keyword: standard of estimate

Search Result 1,443, Processing Time 0.034 seconds

STUDIES ON THE EARLY PREGNANCY DETERMINATION IN COWS BY USING THE ENZYME-IMMUNOASSY AND RADIO-IMMUNOASSAY IN MILK

  • Lee, J.M.;Kim, H.S.;Jeong, S.G.;Jung, J.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.3
    • /
    • pp.299-302
    • /
    • 1996
  • Milk samples(n = 78) were taken 19d, 20d, 21d, 22d after artificial insemination(AI) for early pregnancy diagnosis by using the Enzyme immunoassay(EIA) kit. The progesterone ($P_4$) concentration in the whole milk was measured on the same day of pregnancy diagnosis. Rectal palpation(RP) was accomplished between 60d and 70d after AI to estimate the ovary condition and pregnancy status. Milk progesterone concentrations measured by Radio-immunoassay(RIA) method, in the pregnant cows at 17d, 19d, 21d after insemination were $17.10{\pm}0.91$, $17.60{\pm}0.46$, and $18.43{\pm}0.79nmol/l$, whereas those in the not-pregnant cows were $6.57{\pm}1.03$, $2.63{\pm}0.29$, and $0.67{\pm}0.08nmol/l$, respectively. When the progesterone concentration was less than 7 nmol/l, the color of the EIA kit was lighter and when the progesterone concentration was ${\geq}16nmol/l$, the color of the EIA kit was darker compared to the standard color. The detection rates of error by judging the color differences were 5.1% and 20.7%, respectively. In the early pregnancy diagnosis by the EIA kit and RIA method, the accuracy rates in the pregnancy of cows were 82% and 87%, and those in not-pregnant cows were 86% and 91%, respectively. For ovarian status estimated by the RIA method and certified by RP, the accuracy rates of the ovarian atrophy, follicular cyst and luteal cyst were 80, 91 and 83% and the progesterone concentrations were 2.51, 2.03, and 26.7 nmol/l, respectively.

A Study on U-Turn Location and Length Estimation at Signalized Intersection (신호교차로에서 U-Turn허용구간의 위치 및 적정길이 산정에 관한 연구)

  • Lee, Jung-Hwan;Park, Je-Jin;Ha, Tae-Jun
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.1
    • /
    • pp.203-213
    • /
    • 2008
  • U-Turn offers convenience to drivers. U-Turn increases efficiency of traffic flow. But Standard of U-Turn is not clear. It caused many problems of traffic flow and traffic safety. This study estimate length between U-Turn location with front intersection based on stopping sight distance and left-turn vehicle's queue length. Variables are used traffic volume and operation speed. This study Analysis of U-Turn vehicle's behaviors and classification of conflict form by investigation. U-Turn length estimating based on relationship analysis between conflict with U-Turn length. Variables are used lane changing angles and operation speed. This study estimates length between U-Turn location with back intersection based on gap acceptance theory. Variables are used traffic volume, operation speed and lane changing angles. So, U-Turn location and length estimated considering traffic flow and traffic safety.

Effects of Changing in Wind Environment of Typhoon Approaching to a Building (태풍 접근에 의한 바람 환경 변화가 건물에 미치는 영향)

  • Park, Jong-Kil;Jung, Woo-Sik;Choi, Hyoj-In
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.561-564
    • /
    • 2009
  • In order to reduce damage from natural disasters, prevention activities through analysis and predicting based on meteorological factor and damage data is required. Other countries already have continuously studied on natural disasters and developed reducing disasters damage. But the risk assessment model for natural disaster is not to Korea. Therefore, a previous model of hurricane, Florida Public Hurricane Loss Model(FPHLM), is the basis and is applying to domestic situation. Accordingly, this study introduces the variables selecting process because input variables should be selected under Korea present state and be used. The estimating representative damage method would be necessary along with selecting housing types representing relevant areas because estimating damage amount of all over relevant areas housing was very hard during damage estimating process. But there is no exact representative housing types in the Korea. Therefore, we select housing types applicable to risk assessment model for natural disasters representing the Korea through previous studies and literature reviews. We using ASCE 7-98(Minimum Design Loads for Buildings and Other Structures, 1998) standard which estimated wind load using 3-second gust. ASCE 7-98 divided Main Wind Force Resistance System(MWFRS) and Component and Cladding(C&C) and it estimated wind load. Therefore, we estimate wind load affected by 3-second gust of a typhoon Maemi through calculating wind load process using selected representative detached house types in the process of selecting input variables for previous disaster predict model. The result of houses damage amount is about 230 hundred million won. This values are limit the 1-story detached dwelling, 19~29pyeong(62.81~95.56 $m^2$) of total area and flat roof. Therefore, this process is possible application to other type houses.

  • PDF

A Study on Mutual Relation Analysis and Sensitivity Measurement in Communication Network Operation (네트워크 운용요소별 상관관계 분석 및 민감도 측정에 관한 연구)

  • Kwon, Hyuk-Dae
    • The Journal of Information Technology
    • /
    • v.6 no.4
    • /
    • pp.125-134
    • /
    • 2003
  • This paper is to measure the sensitivity of relations in communication network operation. In order to procure an important adequacy in the network operation and quality improvement, it is necessary to increase network operation efficiency and analyze the characteristic of network operation. Finally, we analyze costing appropriate operation, propose profit increase scheme and apply realistic business. First of all it's important to improve and estimate a proper operating cost thoroughly and comprehensively. Because the important issue of this process is quality process and this quality process occurs customers' satisfaction, therefore, to make a mutual relation in-between individual change of each element is to analyze a reasonable standard. So, for this reason we study on structuring nice models for network operation and estimating many scenarios for measuring efficiency. Especially those in economic and sensitivity based.

  • PDF

Estimation of Ultimate Pullout Resistance of Soil-Nailing Using Nonlinear (비선형회귀분석을 이용한 가압식 쏘일네일링의 극한인발저항력 판정)

  • Park, Hyun-Gue;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.2
    • /
    • pp.65-75
    • /
    • 2016
  • In this study, we constructed a database by collecting field pullout test data of the soil nailing using pressurized grouting, and suggested a method to estimate the ultimate pullout resistance using nonlinear regression analysis to overcome the problems of ultimate pullout resistance estimation using graphical methods. The load-displacement curve estimated by nonlinear regression showed a very high correlation with the field pullout test data. Estimated ultimate pullout load by nonlinear regression method was average 29% higher than estimated ultimate pullout load using previous graphical method. A sigmoidal growth model was found to be the best-fitting nonlinear regression model against rapid pullout failure. Further, an asymptotic regression model was found to be the best fit against progressive nail pullout. The unit ultimate skin friction suggested in this research reflected in the domestic geotechnical characteristics and the specifications of the pressurized grouting method. This research is expected to contribute towards establishing an independent design standard for the soil nailing by providing solutions to the problems that occur when using design charts based on foreign research.

Model-based Macroblock Layer Rate Control for Low Bit Rate Video Coding (저전송률 비디오 압축을 위한 모델 기반 매크로블록 레이어 비트율 제어)

  • Park, Sang-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.4
    • /
    • pp.50-57
    • /
    • 2009
  • This paper presents a new model-based macroblock layer rate control algorithm for low bit rate video coding which generates output bits corresponding to a target bit budget. The H.264 standard uses various coding modes and optimization methods to improve the compression performance, which makes it difficult to control the generated traffic accurately in low bit rate environments. In the proposed scheme, we first estimate MAD values of macroblocks in a frame and define a target remaining bits using the estimated MAD values before encoding each macroblock. If a difference between the target value and the actual value is greater than a threshold value, the quantization parameter is adjusted to decrease the difference. It is shown by experimental results that the new algorithm can obtain more than 66% decrease of the difference between the target bits and the resulting bits for a frame with the PSNR performance better than that of the existing rate control algorithm.

Development of Intelligent Green Fountain Culture System for Healthy Emotional Self-Concept (건강한 정서 자아를 위한 지능형 녹색경관 제어시스템 개발)

  • Park, Seung-Min;Lee, Young-Hwan;Kim, Jun-Yeup;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.281-286
    • /
    • 2012
  • In the growing standard of people's lives, we want desire to create eco-friendly water space what is called the Green Technology that is in the limelight. These green space is introduced the cultural contents and we use the water, music, and nature as tool of emotional verbalism. Presently, when we want to make scenario, water landscape scenario is made by director. but these systems have some disadvantages as the cost and limitation of direction. There is a growing interest in the integrated control system based on PC and Internet. In this paper, it is about fountain control system. Previous research area was only one using programmable logic controller or industrial PC. we proposed the development of intelligent green fountain culture system for healthy emotional self-concept. And we made automatic weather sensing system that is designed by the intelligent green fountain culture system to estimate the time-variant system.

An Experimental Study on Depositional Properties of Cohesive Sediments in Masan Port (마산항 점착성 퇴적물의 퇴적특성에 대한 실험적 연구)

  • Yang, Su-Hyun;Kim, Nam Hun;Hwang, Kyu-Nam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.6
    • /
    • pp.434-442
    • /
    • 2015
  • In this study, a series of deposition tests have been performed using an annular flume in order to estimate depositional parameter of natural sediments. The sediment of Masan Port has been collected for deposition tests, and total 18 deposition tests have been carried out on different bed shear stress respectively but with the same initial concentration. As the results, the minimum bed shear stress ${\tau}_{bmin}$, standard deviation ${\sigma}1$ and time scale parameter $({\tau}_b^*-1)_{50}$ are found to be $0.10N/m^2$, 0.54 and 0.87 respectively. Through comparing with results from previous studies for other sediments, the results of this study are shown to be good enough to verify.

A Study on Characteristic for a Maximum Utilization Factor of Transformer with Regard to Load Characteristics in General Customers (일반용전력사용고객 용도별 부하특성을 고려한 변압기최대이용률 비교 특성 연구)

  • Kim, Se-Dong;Wang, Yong-Peel;Hong, Hyun-Mun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.217-223
    • /
    • 2009
  • This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 461 general customers as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to estimate contract power with characteristics for a regression model for customers(office, store, hotel, hospital, wedding hall) which maximum utilization factor of transformer is more than 60[%].

FLOODING PSA BY CONSIDERING THE OPERATING EXPERIENCE DATA OF KOREAN PWRs

  • Choi, Sun-Yeong;Yang, Joon-Eon
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.215-220
    • /
    • 2007
  • The existing flooding Probabilistic Safety Analysis(PSA) was updated to reflect the Korean plant specific operating experience data into the flooding frequency to improve the PSA quality. Both the Nuclear Power Experience(NPE) database and the Korea Nuclear Pipe Failure Database(NuPIPE) databases were used in this study, and from these databases, only the Pressurized Water Reactor(PWR) data were used for the flooding frequencies of the flooding areas in the primary auxiliary building. With these databases and a Bayesian method, the flooding frequencies for the flooding areas were estimated. Subsequently, the Core Damage Frequency(CDF) for the flooding PSA of the Ulchin(UCN) unit 3 and 4 plants based on the Korean Standard Nuclear Power Plant(KSNP) internal full-power PSA model was recalculated. The evaluation results showed that sixteen flooding events are potentially significant according to the screening criterion, while there were two flooding events exceeding the screening criterion of the existing UCN 3 and 4 flooding PSA. The result was compared with two kinds of cases: (1) the flooding frequency and CDF from the method of the existing flooding PSA with the PWR and Boiled Water Reactor(BWR) data of the NPE database and the Maximum Likelihood Estimate(MLE) method and (2) the flooding frequency and CDF with the NPE database(PWR and BWR data), NuPIPE database, and a Bayesian method. From the comparison, a difference in CDF results was revealed more clearly between the CDF from this study and case (2) than between case (1) and case (2). That is, the number of flooding events exceeding the screen criterion further increased when only the PWR data were used for the primary auxiliary building than when the Korean specific data were used.