• Title/Summary/Keyword: standard measurement methods

Search Result 870, Processing Time 0.034 seconds

Which exercise is the most effective to contract the core muscles: abdominal drawing-in maneuver, maximal expiration, or Kegel exercise? (코어 안정화를 위한 운동의 효과 비교: 복부 드로우 인 기법, 최대 호기, 케겔 운동)

  • Kim, Ji-Seon;Kim, Yang-Hyun;Kim, Eun-Na;Kim, Chae-Rin;Seo, Dong-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.1
    • /
    • pp.83-91
    • /
    • 2016
  • PURPOSE: There are several methods, such as the abdominal drawing-in maneuver (ADIM), maximal expiration (ME), and Kegel exercise, to strengthen the core muscles. However, to date no study has been conducted to compare the effects of the ADIM, ME, and Kegel exercise on the transverses abdominis (TrA), internal oblique (IO), external oblique (EO), and pelvic floor muscles (PFMs). The purpose of this study was to find out which of the three aforementioned exercises is most effective for contracting the core muscles. METHODS: The thickness of the TrA, IO, EO and PFMs was measured by ultrasonographic imaging during the ADIM, ME and Kegel exercise in 34 healthy participants. RESULTS: There was the significant difference between ADIM and Kegel exercise in the thickness of the TrA (p<0.05). There were the significant differences between ADIM and ME and between ME and Kegel exercise in the thickness of the IO and PFM (p<0.01). There was no significant activation in the thickness of the EO (p>0.05). Measurement reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). An ICC value of >0.77 indicated that reliability measurements was good. CONCLUSION: Kegel exercise was the most effective exercise for the TrA and the PFM, and ME was the most effective exercise for the IO muscles.

The Clinical Analysis of the Nasal Septal Cartilage by Measurement Using Computed Tomography

  • Hwang, So Min;Lim, On;Hwang, Min Kyu;Kim, Min Wook;Lee, Jong Seo
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.140-145
    • /
    • 2016
  • Background: The nasal septal cartilage is often used as a donor graft in rhinoplasty operations but can vary widely in size across the patient population. As such, preoperative estimation of the cartilaginous area is important for patient counseling as well as operating planning. We aim to estimate septal cartilage area by using facial computed tomography (CT) studies. Methods: The study was performed using facial CT images taken from 200 patients between January 2012 to July 2015. Using the mid-sagittal image, the boundary of cartilaginous septum was delineated from soft tissue using the mean difference in signal intensity (or brightness). The area within this boundary was calculated. The calculated area for septal cartilage was then compared across age groups and sexes. Results: Overall, the mean area of nasal septal cartilage was $8.18cm^2$ with the maximum of $12.42cm^2$ and the minimum of $4.89cm^2$. The cartilage areas were measured to be larger in men than in women (p<0.05). The area decreased with advancing age (p<0.05). Conclusion: Measuring the size of septal cartilage using brightness difference is more precise and reliable than previously reported methods. This method can be utilized as the standard for prevention of postoperative complication.

Accuracy and Precision of Spectrophotometric Measurement of Clay Content in Soils (분광광도계를 이용한 점토함량 분석의 정확성 및 정밀성 평가)

  • Park, Soon-Nam;Kim, Kye-Hoon;Kang, Ji-Young
    • Applied Biological Chemistry
    • /
    • v.49 no.2
    • /
    • pp.153-157
    • /
    • 2006
  • Accuracy and precision of the spectrophotometeric analysis of clay content in soils were estimated by comparison with the conventional pipet method. Clay contents in 25 soil samples of various physico-chemical properties including texture were determined by spectrophotometry and pipet methods, and the two sets of data an clay content were compared by several statistical analyses. The correlation between clay contents determined by spectrophotometry and pipet methods was highly significant. The regression coefficient was $0.98^{**}$ and the slope of regression equation was close to 1.0. The standard deviation and CV of clay contents measured by spectorphotometry were smaller than those found in the data of clay contents obtained by pipet method. In conclusion, compared to the conventional pipet method, spectrophotometry was a rapid, convenient, accurate and precise method for the measurement of clay content in soils.

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

The Elementary Study on the Development for Test Methods of Load Resistance about Attachments on the Lightweight Wall (경량벽체의 부착물에 대한 하중저항성 평가방법 개발을 위한 기초적 연구)

  • Kim, Sang-Heon;Kim, Se-Whan;Choi, Soo-Kyung;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.119-126
    • /
    • 2015
  • The wall system has been also tending to shift from existing concrete wall to variable lightweight wall according to increasing use of column structure system in apartment construction. Therefore, wall needs certain amount of strength which also means the standard measurement of resistance against loading of wall attachments is needed. Nevertheless, there currently aren't enough researches of related standards for such measurement. For such reason, the research would be used as baseline data to development for test methods of load resistance about attachments on the lightweight wall, that presented improvements in the apparatus and maximum loads for domestic circumstances by researching current tests.

pH Sensor Application of Printed Indium-Tin-Oxide Nanoparticle Films (Indium-Tin-Oxide 나노입자 인쇄박막의 pH sensor 응용에 대한 연구)

  • Lee, Changhan;Noh, Jaeha;An, Sangsu;Lee, Sangtae;Seo, Dongmin;Lee, Moonjin;Chang, Jiho
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.85-89
    • /
    • 2022
  • We investigated a pH sensor using an Indium tin oxide (ITO) nanoparticle (NP) film printed on a flexible substrate. First, the printing precision and mechanical stability of the ITO-printed film were investigated. In particular, the factors that influence the crystallinity of ITO films were studied using X-ray diffraction pattern analysis. The response of the ITO pH sensor was calibrated using a series of standard pH solutions (pH 3-11). The pH values of various specimens were measured using an ITO pH sensor, and the results were compared with those of various pH measurement methods. As a result of the experiment, the maximum error was approximately ± 0.04 pH (0.4 %) at pH 9, which indicated that the ITO pH sensor is highly suitable for pH measurement. Finally, we used the ITO pH sensor to the measure of general specimens such as solvents and beverages and compared the results in comparison with those obtained from several conventional methods.

Comparison analysis of physiological work capacity for different tasks (작업유형에 따른 생리학적 작업능력의 비교 분석)

  • 박지수;김홍기;최진영
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.89-98
    • /
    • 1996
  • The objective of this study was to make comparison of the physical work capacities with different types and methods of tasks. To produce standard work loads, a bicycle ergometer and a treadmill were used for the purpose of two different types of tasks. Maximal oxygen uptake measurement tests are usually performen (1) continuously - with no rest between work load increments, or (2) discontinuously - with the subjects resting several minutes between work periods. Continuous test protocol with two different methods of work load increments, (1) ramp test- with 3 to 5 minutes of work period for each work load, and (2) incremental test - where exercise intensity was increased progressively in 2 minutes interval, were used. Predicted physicala work capacities (PWCs) were compared with the one by Kim(1990), and Lee(1995), and the NIOSH physiological criteria. For ergometer test, the PWC based on the ramp test was 89.65% of the one based on the incremental test. The PWC values were 2553.88 ml/min for the ramp test and 2848.82 ml/min for the incremental test. For treadmill test, the PWC based on the ramp test was 97.54% of the one based on the incremental test. The PWC values were 2786.89 ml/min for the ramp test and 2857.24 ml/min for the incremental test. The PWC obtained with a bicycle ergometer was 91.64% of the one obtained with a treadmill for the ramp test, and 99.71% for the incremental test.

  • PDF

Design guide for full-face blasting in highway tunnel (고속도로 터널에 대한 전단면 발파 설계방안 연구)

  • Lee, Sang-Don;Choi, Hae-Moon;Lee, Hyun-Koo;Ryu, Chang-Ha
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.930-937
    • /
    • 2004
  • In tunnel blasting, rock damage and overbreak at excavation limits are strongly related to stability of the tunnel and cost for rock support, and also affect to maintenance after tunnel construction. In this study, many field tests and measurements have been carried out in highway tunnels so that discordance between blast design and practical production blasting could be settled and actual methods of over break control could be proposed through the understanding of the problems in existing blasting patterns. Test blasting in tunnel was carried out many times in two tunnel sites. Also, long hole blasting longer than existing blasting pattern was executed for good grade of rock mass whose RMR value is more than 60. Using the results of test blasting, new standard blasting patterns for two lane tunnel were proposed. As a result of profile measurement after blasting, drilling is a major factor of overbreak. And then the methods for minimizing overbreak were adapted in new blasting patterns.

  • PDF

The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment (신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구)

  • Lee, Yun Gyu;Shin, Cheol Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.606-611
    • /
    • 2013
  • In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

A Study on the Change of Mass in Flow Velocity Using Loss Resistane Test Method - Using Synthetic rubber system Repair material - (유실저항성 시험방법을 이용한 유속조건에서의 질량변화 추이 연구 합성고무계 보수재료를 중심으로-)

  • Park, So-Young;Jang, Bo;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.127-128
    • /
    • 2017
  • Tests are conducted according to the ISO TS 16774, Part 3 standard for quality management of leakage repair materials used in cracks in underground concrete structures. These test methods are performed indirectly using a nonwoven fabric on a chalet containing leak repair materials. However, it is considered that it is appropriate to verify the resistance of the repair material, which is required to be applied directly to the cracks in the actual field and to exhibit the resistance of the flow velocity. In this study, mass change was measured by using nonwoven fabric and nonwoven fabric. As a result, both methods showed an increase in mass, which indicated that the maintenance material itself contained a large amount of water, and that the mass change occurred depending on the drying state. Also, depending on the use of nonwoven fabric, the error due to the indirect test could not be ruled out. Therefore, further verification is needed, and it is considered that the test for change of mass reduction measurement is necessary according to the drying time of other types of the same series.

  • PDF