Accuracy and precision of the spectrophotometeric analysis of clay content in soils were estimated by comparison with the conventional pipet method. Clay contents in 25 soil samples of various physico-chemical properties including texture were determined by spectrophotometry and pipet methods, and the two sets of data an clay content were compared by several statistical analyses. The correlation between clay contents determined by spectrophotometry and pipet methods was highly significant. The regression coefficient was $0.98^{**}$ and the slope of regression equation was close to 1.0. The standard deviation and CV of clay contents measured by spectorphotometry were smaller than those found in the data of clay contents obtained by pipet method. In conclusion, compared to the conventional pipet method, spectrophotometry was a rapid, convenient, accurate and precise method for the measurement of clay content in soils.
Keywords
spectrophotometry; pipet method; clay content;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Stockham, J. D. and Fochtman, E. G. (1979) In Particle size analysis. (3rd ed.) Ann Arbor Science, Michigan
2 Bouyoucos, G. J. (1933) A comparison between the pipette method and the hydrometer method for making mechanical analysis of soils, with new directions. Soil Sci. 38, 335-343
3 Day, P. R. 1950. Physical basis of particle size analysis by the hydrometer method. Soil Sci. 70, 363-374   DOI
4 Sur, H. S. and Kukal, S. S. (1992) A modified hydrometer procedure for particle size analysis. Soil Sci. 153, 1-4   DOI
5 Coakley, J. P. and Syvitski, J. P. M. (1991) Sedigraph technique. In Principles, methods, and application of particle size analysis. J. P. M. Syvitski. pp. 130-142. Cambridge University Press, New York
6 Pennington, K. L. and Lewis, G. C. (1979) A comparison of electronic and pipet methods for mechanical analysis of soils. Soil Sci. 128, 280-284   DOI
7 Liu, T. K., Odell, R. T., Etter, W. C. and Thornburn, T. H. (1966) A comparison of clay contents determined by hydrometer and pipette methods using reduced major axis analysis. Soil Sci. Soc. Am. Proc. 30, 665-669   DOI
8 Welch, N. H., Allen, P. B. and Galindo, D. J. (1979) Particlesize analysis by pipette and SediGraph. J. Environ. Qual. 8, 543-546   DOI   ScienceOn
9 Vaz, C. M. P., Oliveira, J. C. M., Reichardt, K., Crestana, S., Cruvinel, P. E. and Bacchi, O. O. S. (1992) Soil mechanical analysis through gamma ray attenuation. Soil Technol. 5, 319-325
10 Miller, W. P. and Miller, D. M. (1987) A micro-pipette method for soil mechanical analysis. Commun. Soil Sci. Plant Anal. 18, 1-15   DOI
11 Naime, J. M., Vaz, C. M. P. and Macedo, A. (2001) Automated soil particle size analyzer based on gamma-ray attenuation. Comput. Electron. Agric. 31, 295-304   DOI   ScienceOn
12 Buurman, P., Pape, T. and Muggler, C. C. (1997) Laser grainsize determination in soil genetic studies 1. Practical problems. Soil Sci. 162, 211-218   DOI
13 Elias, E. A., Bacchi, O. O. S. and Reichardt, K. (1999) Alternative soil particle-size analysis by gamma-ray attenuation. Soil Tillage Res. 52, 121-123   DOI   ScienceOn
14 Chung, J. B., Kim, M. K., Kim, B. J. and Kim, K. H. (1999) Comparison of micro-pipette method and hydrometer method in soil particle size analysis. J. Kor. Soc. Soil Sci. Fert. 32, 274-278
15 Hyun, B. K., Kim, M. S., Eom, K. C. and Jo, I. S. (2000) A more simplified hydrometer method for soil texture analysis. J. Kor. Soc. Soil Sci. Fert. 33, 153-159
16 Kilmer, V. J. and Alexander, L. T. (1949) Methods of making mechanical analyses of soils. Soil Sci. 68, 15-24   DOI
17 Gee, G. W. and Bauder, J. W. (1986) Particle size analysis. In Methods of Soil Analysis Part 1, A. Klute (2nd ed.) pp. 383-411. American Society of Agronomy, Madison, WI
18 Beuselinck, L., Govers, G., Poesen, J. and Degraer, G. (1998) Grain-size analysis by laser diffractometry: comparison with the sieve-pipette method. Catena 32, 193-208   DOI   ScienceOn
19 Daddah, M. T. (1974) The hydrometer method for detailed particle-size anslysis: 1. Graphical interpretation of hydrometer readings and test of method. Soil Sci. 118, 102-108   DOI
20 Park S. N., Kim, K. H. and Kang, J. Y. (2005) Use of spectrophotimetry for quantitative determination of soil clay content. J. Korean. Appl. Biol. Chem. 48, 183-188   과학기술학회마을
21 Oliverira, J. C. M., Vaz, C. M. P., Reichardt, K. and Swartzendruber, D. (1997) Improved soil particle-size analysis by gamma-ray attenuation. Soil Sci. Soc. Am. J. 61, 23-26   DOI   ScienceOn
22 Muggler, C. C., Pape, T. and Buurman, P. (1997) Laser-grain size determination in soil genetic studies 2. Clay content, clay formation, and aggregation in some Brazilian oxisols. Soil Sci. 162, 219-228   DOI
23 Allen, T. (1997) In Particle size measurement. (5th ed.) Chapman and Hall, New York
24 Jo, I. S., Kim, L. Y., Ryu, K. S., Im, J. N., Um, K. T. and Kwag, Y. S. (1984) Design and performance of the modified hydrometer for the rapid measurement of clay content in soils. J. Kor. Soc. Soil Sci. Fert. 17, 325-329