• Title/Summary/Keyword: standard measurement methods

Search Result 873, Processing Time 0.028 seconds

Development of the structural health record of containment building in nuclear power plant

  • Chu, Shih-Yu;Kang, Chan-Jung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.2038-2045
    • /
    • 2021
  • The main objective of this work is to propose a reliable routine standard operation procedures (SOP) for structural health monitoring and diagnosis of nuclear power plants (NPPs). At present, NPPs have monitoring systems that can be used to obtain the quantitative health record of containment (CTMT) buildings through system identification technology. However, because the measurement signals are often interfered with by noise, the identification results may introduce erroneous conclusions if the measured data is directly adopted. Therefore, this paper recommends the SOP for signal screening and the required identification procedures to identify the dynamic characteristics of the CTMT of NPPs. In the SOP, three recommend methods are proposed including the Recursive Least Squares (RLS), the Observer Kalman Filter Identification/Eigensystem Realization Algorithm (OKID/ERA), and the Frequency Response Function (FRF). The identification results can be verified by comparing the results of different methods. Finally, a preliminary CTMT healthy record can be established based on the limited number of earthquake records. It can be served as the quantitative reference to expedite the restart procedure. If the fundamental frequency of the CTMT drops significantly after the Operating Basis Earthquake and Safe Shutdown Earthquake (OBE/SSE), it means that the restart actions suggested by the regulatory guide should be taken in place immediately.

The comfort evaluation and analysis of the urban rail vehicle (도시철도차량 시트의 안락성 평가 및 분석)

  • Goo, Jae-Kwang;Suh, Woo-Sung;Choi, Se-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.222-228
    • /
    • 2007
  • In order to solve the problem of traffic holdups and environmental pollution(contamination), several metropolises are operating the subway and many local government plans hereafter the light rail vehicle operation and it is in the process of preparing. This point of time, it need to evaluate the comfortable characteristic of the seat which is closely connected with passenger and it should be reflected to the product design through the data analysis. The methods of the comfortable characteristic evaluation should be considered to various methods from physical factor to psychological factor. Among these, the most universal and possible quantitative measurement estimate through 'Body pressure measurement system'. From this paper, it was measured the body pressure of the subway seat which is in the process of operating in a domestic and it will be compared and analyzed the material & seat shape, so we evaluated the comfortable characteristic of the short-distance transportation railway vehicle. It was operated the man and woman who belongs in standard shape of Korean, we compared and analyzed the Peak position where the body pressure is visible and body pressure spread out.

  • PDF

A Study on Measurement of Repetitive Work using Digital Image Processing (영상처리를 이용한 반복적 작업의 측정에 관한 연구)

  • Lee, Jeong-Cheol;Sim, Eok-Su;Kim, Nam-Joo;Park, Chan-Kwon;Park, Jin-Woo
    • IE interfaces
    • /
    • v.14 no.1
    • /
    • pp.95-105
    • /
    • 2001
  • Previous work measurement methods need much time and effort of time study analysts because they have to measure required time through direct observations. In this study, we propose a method which efficiently measures standard times without involvement of human analysts using digital image processing techniques. This method consists of two main steps: motion representation step and cycle segmentation step. In motion representation step, we first detect the motion of any object distinct from its background by differencing two consecutive images separated by a constant time interval. The images thus obtained then pass through an edge detector filter. Finally, the mean values of coordinates of significant pixels of the edge image are obtained. Through these processes, the motions of the observed worker are represented by two time series data of worker location in horizontal and vertical axes. In the second step, called the cycle segmentation step, we extract the frames which have maximum or minimum coordinates in one cycle and store them in a stack, and calculate each cycle time using these frames. In this step we also consider methods on how to detect work delays due to unexpected events such as operator's escapement from the work area, or interruptions. To condude, the experimental results show that the proposed method is very cost-effective and useful for measuring time standards for various work environment.

  • PDF

RAPID PREDICTION OF ENERGY CONTENT IN CEREAL FOOD PRODUCTS WITH NIRS.

  • Kays, Sandra E.;Barton, Franklin E.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1511-1511
    • /
    • 2001
  • Energy content, expressed as calories per gram, is an important part of the evaluation and marketing of foods in developed countries. Currently accepted methods of measurement of energy by U.S. food labeling legislation include measurement of gross calories by bomb calorimetry with an adjustment for undigested protein and by calculation using specific factors for the energy values of protein, carbohydrate less the amount of insoluble dietary fiber, and total fat. The ability of NIRS to predict the energy value of diverse, processed and unprocessed cereal food products was investigated. NIR spectra of cereal products were obtained with an NIR Systems monochromator and the wavelength range used for analysis was 1104-2494 nm. Gross energy of the foods was measured by oxygen bomb calorimetry (Parr Manual No. 120) and expressed as calories per gram (CPGI, range 4.05-5.49 cal/g). Energy value was adjusted for undigested protein (CPG2, range 3.99-5.38 cal/g) and undigested protein and insoluble dietary fiber (CPG3, range 2.42-5.35 cal/g). Using a multivariate analysis software package (ISI International, Inc.) partial least squares models were developed for the prediction of energy content. The standard error of cross validation and multiple coefficient of determination for CPGI using modified partial least squares regression (n=127) was 0.060 cal/g and 0.95, respectively, and the standard error of performance, coefficient of determination, bias and slope using an independent validation set (n=59) were 0.057 cal/g, 0.98, -0.027 cal/g and 1.05 respectively. The PLS loading for factor 1 (Pearson correlation coefficient 0.92) had significant absorption peaks correlated to C-H stretch groups in lipid at 1722/1764 nm and 2304/2346 nm and O-H groups in carbohydrate at 1434 and 2076 nm. Thus the model appeared to be predominantly influenced by lipid and carbohydrate. Models for CPG2 and CPG3 showed similar trends with standard errors of performance, using the independent validation set, of 0.058 and 0.088 cal/g, respectively, and coefficients of determination of 0.96. Thus NIRS provides a rapid and efficient method of predicting energy content of diverse cereal foods.

  • PDF

A Study on the Technical Standard of Micro-Inverter for Domestic Photovoltaic Power Generation (국내 태양광발전용 마이크로 인버터 기술기준에 관한 연구)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.175-180
    • /
    • 2019
  • In order to overcome the drawbacks of low rated power of the string inverter, the necessity of micro -inverters and future development directions will be examined by comparing the power conditioner system with existing PCS using micro inverter. Currently, string inverters have been used in household solar power generation systems, and research and penetration of micro-inverters(PV-MIC) have been expanding, which can overcome the shortcomings of string inverters starting from Europe. However, in the PV inverter industry, precise technical standards, test measurement equipment and related test methods for micro-inverters(PV-MIC) are obstacles to product development. Therefore, in this paper, considering the characteristics of micro-inverter (PV-MIC), it aims to make it competitive so that it does not lag behind advanced technology change through test measurement equipment and related technical standard.

Estimation of Attributable Burden due to Premature Death from Smoking in Korea (우리 나라 흡연으로 인한 조기사망의 질병부담)

  • Ha, Beom-Man;Kang, Jong-Won;Chang, Hye-Chung;Yoon, Seok-Jun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.191-199
    • /
    • 2001
  • Objective : In this study, we focused on estimating the burden of premature death in Korea caused by smoking using the YLL(years of life lost due to premature death) measurement. Methods : First, we determined parameters: such as age-specific standard life expectancy, age on death, sex, and cause of death by analyzing the national death certificate data and life table collected during 1997. These were provided by the National Statistical Office. Secondly, we estimated the age group- specific years of life lost due to premature death by employing the standard expected years of life lost(SEYLL) measurement. Thirdly, the burden of premature death caused by smoking was estimated using the YLLs measurement which was developed by the global burden of disease study group. Fourthly, We calculated the risk related to smoking using the population attributable risk. Results : The following results were obtained in this study: 1) Premature death that is attributable to smoking in males could be prevented in 60.9%(513,582 person-year) by non-smoking. 2) The burden of premature death by smoking for female was prevented to 17.7%(513,582 person-year) by non-smoking. Conclusion : We found that the YLL method employed in this study was appropriate in quantifying the burden of premature death. This provides a rational basis for planning a national health policy regarding premature deaths caused by smoking and other related risk factors.

  • PDF

Comparison of Precision for Available Phosphate Measurement between Lancaster and Soiltek KA-1 Spectrophotometric Method (Lancaster 법과 Soiltek KA-1 분광광도계를 이용한 유효인산 측정법의 정밀도 비교)

  • Hyun, Hae-Nam;Lim, Han-Cheol;Eom, Ki-Cheol;Kim, Yoo-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.3
    • /
    • pp.268-273
    • /
    • 1999
  • To measure the precision of Soiltek$^{(R)}$ KA-1 spectrophotometric measurement of soil available phosphate, standard deviation, C;V, and relative sensitivity were investigated, comparing to Lancaster method. Available phosphate concentration measured by Soiltek$^{(R)}$ KA-1 spectrophotometric method was highly correlated with Lancaster method($r=0.998^{***}$) and the slop of regression equation was close to 1.0. There were no differences in standard deviation. CV, and relative sensitivity for soil available phosphate concentrations measured by two methods. Regarding to convenience of experimental procedure and instrumental operation, and time saving analysis, Soiltek$^{(R)}$ KA-1 spectrophotometric measurement for soil available phosphate is highly recommended.

  • PDF

Strengthening the Occupational Exposure Limit for 1-Bromopropane according to the Results of Epidemiological Studies and Exposure Status (1-브로모프로판의 노출 실태와 역학조사에 따른 노출기준 강화에 관한 연구)

  • Ha, Kwonchul;Kim, Seung Won;Phee, Young Gyu;Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.3
    • /
    • pp.270-279
    • /
    • 2020
  • Objective: The aim of this study was to propose revision of the occupational exposure limit(OEL) for 1-Bromopropane(1-BP) following a review of the appropriateness of the standard in light of increasing epidemiological data and handling risk. Materials and Methods: The results of toxicity and epidemiologic investigations for 1-BP and agencies' OELs were compared and reviewed through a literature review. In order to investigate the status of 1-BP handling in South Korea, data from work environment actual condition survey results and work environment measurement results were used. Results: The toxicity of 1-BP, such as central nervous system(CNS) damage, peripheral neuropathy, hematological adverse effects, and developmental and reproductive toxicity(male and female) has been reported. ACGIH recommends 0.1 ppm as a TLV-TWA value, but the OEL of South Korea stands at 25 ppm, which is 250 times higher than the TLV-TWA. Although 1-BP is a specially managed substance under the Industrial Safety and Health Law, the currently applied OEL cannot be said to be a safe level based on the results of epidemiological studies to date. In a work environment measurement in 2017, the total number of samples was 626, which were derived from 78 industries, and the average concentration was 1.173 ppm(standard deviation 2.88). Conclusions: To protect the health of workers handling 1-BP, estimated to be 780 in South Korea, it is necessary to strengthen the OEL(TWA) to a level of 0.3 ppm(lower than the 0.34 ppm with known toxic effects), which is believed to be safe as a result of epidemiological investigation. "Skin" notation should be recommended.

Analysis of the Bone Proportional Method for Determining Acupoints in the Upper and Lower Abdominal Region in Males and Females

  • Kang, Yeonseol;Park, Jungjoon;Lee, Taerim;Yang, Giyoung;Chae, Han;Lee, Byungryul
    • Journal of Acupuncture Research
    • /
    • v.36 no.4
    • /
    • pp.264-271
    • /
    • 2019
  • Background: The purpose of this study was to redefine the location of acupoints in the lower abdomen by taking actual thoracic and abdominal measurements. Methods: Measurements of the length and height of the thorax, and both the upper and lower abdominal area were compared to standard values defined by the World Health Organization Western Pacific Region (WHO/WPRO), and medical text books such as Miraculous Pivot, and A-B Classic of Acupuncture and Moxibustion. These measurements were used to redefine the standard of 1 cun, and the cun value of the lower abdomen. Results: Of the 60 studies screened, all studies used the cun measurement system. Considerable variation in the localization of acupoints in the lower abdominal area were detected. The average measurement of a typical male lower abdomen was within 6.33 cun to 6.34 cun. From this data, 6.5 cun appears to be more accurate than the current standardized length of 5 cun. The standardized index values of the width of the 4 fingers, and the distance from the lateral prominence from the greater trochanter to the popliteal crease (Fm), appeared to apply to only males, as defined by the WHO/WPRO. Conclusion: Further studies on standardizing the index measurements for the lower abdominal area are necessary. For males, the more accurate standardized length of the lower abdomen was 6.5 cun, whereas for females, the measurement would typically be longer than 6.5 cun.

Test-retest Reliability and Concurrent Validity of a Headphone and Necklace Posture Correction System Developed for Office Workers

  • Gyu-hyun Han;Chung-hwi Yi;Seo-hyun Kim;Su-bin Kim;One-bin Lim
    • Physical Therapy Korea
    • /
    • v.30 no.3
    • /
    • pp.174-183
    • /
    • 2023
  • Background: Office workers experience neck or back pain due to poor posture, such as flexed head and forward head posture, during long-term sedentary work. Posture correction is used to reduce pain caused by poor posture and ensures proper alignment of the body. Several assistive devices have been developed to assist in maintaining an ideal posture; however, there are limitations in practical use due to vast size, unproven long-term effects or inconsistency of maintaining posture alignment. We developed a headphone and necklace posture correction system (HANPCS) for posture correction using an inertial measurement unit (IMU) sensor that provides visual or auditory feedback. Objects: To demonstrate the test-retest reliability and concurrent validity of neck and upper trunk flexion measurements using a HANPCS, compared with a three-dimensional motion analysis system (3DMAS). Methods: Twenty-nine participants were included in this study. The HANPCS was applied to each participant. The angle for each action was measured simultaneously using the HANPCS and 3DMAS. The data were analyzed using the intraclass correlation coefficient (ICC) = [3,3] with 95% confidence intervals (CIs). Results: The angular measurements of the HANPCS for neck and upper trunk flexions showed high intra- (ICC = 0.954-0.971) and inter-day (ICC = 0.865-0.937) values, standard error of measurement (SEM) values (1.05°-2.04°), and minimal detectable change (MDC) values (2.92°-5.65°). Also, the angular measurements between the HANPCS and 3DMAS had excellent ICC values (> 0.90) for all sessions, which indicates high concurrent validity. Conclusion: Our study demonstrates that the HANPCS is as accurate in measuring angle as the gold standard, 3DMAS. Therefore, the HANPCS is reliable and valid because of its angular measurement reliability and validity.