• 제목/요약/키워드: standard manufacturing shape

검색결과 76건 처리시간 0.028초

주문생산을 위한 자동제도 토르소 원형연구 -20대 여성을 중심으로- (A Study on the Development of Torso Pattern for an Automated Order-based Manufacturing System - focused on women in the twenties -)

  • 황수연;남윤자
    • 대한인간공학회지
    • /
    • 제21권1호
    • /
    • pp.67-80
    • /
    • 2002
  • An efficient torso pattern has been developed to cope with the future trend of order-based, individualized production like the E.C.(Electronic Commerce) in the apparel industry, and to make a database foundation of automatic garment pattern drafting. For this purpose, a non-contact three-dimensional anthropometric measurement system was used to provide a lot of accurate body data for better individual fit, and an automatic pattern drafting system that can easily generate various size patterns and construct a pattern database has been developed too. The subjects of this research were 18 to 24 year-old women whose data had been gathered through the Korean national investigation of anthropometry for industrial standards in 1997 and various body shapes were analyzed by the measurements. And a special software system has been developed to verify the validity of newly proposed drawing rules. The results of sensory evaluation for appearance and moving fitness of the new torso pattern showed a significant improvement in individual fit even for the figures with large deviation from standard shape compared with the results of the traditional one.

T형 평면용접이음재의 응력해석과 굽힘피로강도에 관한 연구 (A Study on Stree Analysis and Bending Fatigue Strength of One Side Fillet Welded T-joint)

  • 강성원;이태훈;전재목;김충희
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.51-57
    • /
    • 1999
  • In this study, one side fillet welded T-joint, used in box type girder and other welding structure, was investigated by stress analysis and bending fatigue test without edge preparation, with variation of joint shape. The purpose of this study is to give the welding condiltion and design standard on manufacturing one side fillet welded T-joint. As a result, the following conclusions were obtained. 1) In one side fillet welded T-joint, the larger the leg length and the penetration depth, the greater the bending fatigue strength because reduction of stress and strain on toe and root. The increase of the longitudinal leg length rather than vertical leg length contributed to the increase in bending fatigue strength. 2) In one side fillet welded T-joint without edge preparation, both general manual welding and general automatic welding were carried out with same condition. In this case, automatic welding showed deeper penetration and more increased longitudinal leg length than manual welding, so that automatic welding offers greater bending fatigue strength. 3) For one side fillet welded T-joint without edge preparation with automatic welding, the ratio(h/t) of the leg length(h) and the main plate thickness(t) in which toe crake can occur was 1.0 over.

  • PDF

신경망을 이용한 한국형 표준 신발금형설계 (The Shoe Mold Design for Korea Standard Using Artificial Neural Network)

  • 최정일;이정민;백상현;김병민;김동환
    • 소성∙가공
    • /
    • 제24권3호
    • /
    • pp.167-175
    • /
    • 2015
  • In the current study, the design methodology has been developed to produce shoe mold for a suitable walking shoes of the general Korean using ANN (Artificial Neural Network). To design the suitable and comfortable shoes for the Korean, the shapes of foots were measured for 513 people. In this research, the foot length, breadth and ankle were considered as design parameters. In order to find the optimal foot shape for the average value of design parameters, the average value of design parameters and the other measurements were used as input and output to the ANN. After training, the various foot measurements were predicted by ANN. Base on the ANN results, the walking shoes were manufactured by considering these measurements and designing a shoe mold. From the results, the proposed method could give a more systematic and feasible means for manufacturing walking shoes with greater usefulness and better generality.

하중저항계수설계법 및 정밀해법에 의한 PFRP I형 단면 압축재의 국부좌굴강도 (Local Buckling Strength of PFRP I-Shape Compression Members Obtained by LRFD Design Method and Closed-Form Solution)

  • 최진우;서수홍;주형중;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제5권2호
    • /
    • pp.1-8
    • /
    • 2014
  • Fiber reinforced polymeric plastic (FRP) materials have many advantages over conventional structural materials, i.e., high specific strength and stiffness, high corrosion resistance, right weight, etc. Among the various manufacturing methods, pultrusion process is one of the best choices for the mass production of structural plastic members. Since the major reinforcing fibers are placed along the axial direction of the member, this material is usually considered as an orthotropic material. However, pultruded FRP (PFRP) structural members have low modulus of elasticity and are composed of orthotropic thin plate components the members are prone to buckle. Therefore, stability is an important issue in the design of the pultruded FRP structural members. Many researchers have conducted related studies to publish the design method of FRP structures and recently, referred to the previous researches, pre-standard for LRFD of pultruded FRP structures is presented. In this paper, the accuracy and suitability of design equation for the local buckling strength of pultruded FRP I-shape compression members presented by ASCE are estimated. In the estimation, we compared the results obtained by design equation, closed-form solution, and experiments conducted by previous researches.

원자력 구조재 신뢰성 향상을 위한 열피로 균열 시험편 제작 기법 개발 (Development the Technique for Fabrication of the Thermal Fatigue Crack to Enhance the Reliability of Structural Component in NPPs)

  • 김용;김재성;이보영
    • Journal of Welding and Joining
    • /
    • 제26권2호
    • /
    • pp.43-49
    • /
    • 2008
  • Fatigue cracks due to thermal stratification or corrosion in pipelines of nuclear power plants can cause serious problems on reactor cooling system. Therefore, the development of an integrated technology including fabrication of standard specimens and their practical usage is needed to enhance the reliability of nondestructive testing. The test material was austenitic STS 304, which is used as pipelines in the Reactor Coolant System of a nuclear power plants. The best condition for fabrication of thermal fatigue cracks at the notch plate was selected using the thermal stress analysis of ANSYS. The specimen was installed from the tensile tester and underwent continuos tension loads of 51,000N. Then, after the specimen was heated to $450^{\circ}C$ for 1 minute using HF induction heater, it was cooled to $20^{\circ}C$ in 1 minute using a mixture of dry ice and water. The initial crack was generated at 17,000 cycles, 560 hours later (1cycle/2min.) and the depth of the thermal fatigue crack reached about 40% of the thickness of the specimen at 22,000 cycles. As a results of optical microscope and SEM analysis, it is confirmed that fabricated thermal fatigue cracks have the same characteristics as real fatigue cracks in nuclear power plants. The crack shape and size were identified.

액체생검용 Lab-on-a-Disc의 평탄도 향상을 위한 최적화 (Design Optimization to achieve an enhanced flatness of a Lab-on-a-Disc for liquid biopsy)

  • 홍석관;이정원;황택용;이성훈;김경태;강태곤;황철진
    • Design & Manufacturing
    • /
    • 제17권1호
    • /
    • pp.20-26
    • /
    • 2023
  • Lab-on-a-disc is a circular disc shape of cartridge that can be used for blood-based liquid biopsy to diagnose an early stage of cancer. Currently, liquid biopsies are regarded as a time-consuming process, and require sophisticated skills to precisely separate cell-free DNA (cfDNA) and circulating tumor cells (CTCs) floating in the bloodstream for accurate diagnosis. However, by applying the lab-on-a-disc to liquid biopsy, the entire process can be operated automatically. To do so, the lab-on-a-disc should be designed to prevent blood leakage during the centrifugation, transport, and dilution of blood inside the lab-on-a-disc in the process of liquid biopsy. In this study, the main components of lab-on-a-disc for liquid biopsy are fabricated by injection molding for mass production, and ultrasonic welding is employed to ensure the bonding strength between the components. To guarantee accurate ultrasonic welding, the flatness of the components is optimized numerically by using the response surface methodology with four main injection molding processing parameters, including the mold & resin temperatures, the injection speed, and the packing pressure. The 27 times finite element analyses using Moldflow® reveal that the injection time and the packing pressure are the critical factors affecting the flatness of the components with an optimal set of values for all four processing parameters. To further improve the flatness of the lab-on-a-disc components for stable mass production, a quarter-disc shape of lab-on-a-disc with a radius of 75 mm is used instead of a full circular shape of the disc, and this significantly decreases the standard deviation of flatness to 30% due to the reduced overall length of the injection molded components by one-half. Moreover, it is also beneficial to use a quarter disc shape to manage the deviation of flatness under 3 sigma limits.

  • PDF

Under-Wear의 착용감과 착용방법에 관한 연구 (A Study of the Wearing Sensation and Wearing Way of the Under Wear)

  • 임순
    • 복식문화연구
    • /
    • 제6권4호
    • /
    • pp.26-38
    • /
    • 1998
  • This paper is based on a survey of consumers 'opinions on underwears. The questions in the survey dealt with what materials were used to manufacture underwears, which underwears were worn together in combinations, and how comfortable underwears were. In addition, the respondents were asked about how many pieces of different underwears they posses. Through such research, this paper aims to provide a guide to manufacturing domestic underwears that are competitive against foreign bands. 336 women in their twenties, thirties, forties and fifties from Seoul and it's suburbs were surveyed. Statistical analysis was performed by calculating the average, frequency and standard deviation, and through one-way analysis and the Duncan test. The following are the results of the study : 1. Consumers were moderately satisfied with Korean-made underwears. In order to complete with foreign brands, products with high consumer-satisfaction levels must be produced. 2. Upper garments usually consisted of brassieres with shoulder straps and sleeveless shirts. For lower underwears, most people tended to wear panties under girdle, with garlets on top. This is most likely the resut of more people wearing slacks than skirts. 3. Consumer in their twenties had anaverage of 1.71 slips, while those in their thirties had 3.07, those in their forties and 3.25, and people in their fifties had 3.88 slips. Thus the number of slips a consumer possesses increases as age increases. for socks, people in their twenties had 7.4 pairs on average, those in their thirties had 5.5, those in their forties had 6.7, and those in their fifties had 5.3. Thus, those in their twenties possessed the most number of socks. Consumers in their twenties also had the largest proportion of socks among all the types of hosiery combined, with 47.1% of their hosiery being socks. 4. Consumers did tend to prefer cotton underwears, but according to the type of underwears, producting using mixed fabrics of cotton and synthetic fibers were also frequently worn. 5. The shape and form of underwear that consumers prefer in a ceratin time frame varies according to the latest fashion in outer wear. Therefore, planning design of underwear products by predicting the future trend of outer wear fashion is necessary.

  • PDF

성인여성용 브래지어원형 개발 연구(제1보) -75A 치수를 중심으로- (A Study on the Development of Basic Brassiere Pattern for Adult Women -focusing on size 75A-)

  • 박은미;손희순
    • 한국의류학회지
    • /
    • 제25권4호
    • /
    • pp.719-730
    • /
    • 2001
  • The purpose of this study is to develop the basic patterns of adult womens brassiere therewith, provide for some basic data useful to the brassiere manufacturing which are both functional and fitting. For this purpose, 220 adults women(aged between 20 and 59) were sampled to be measured for their body sizes and tested for their brassiere wearing. The collected data were statistically processed using the SAS 6.12 for Means, Standard Deviation, etc. The results of this study can be summarized as follows; 1. In order to develop the basic patterns of adult womens brassieres, 75A size was selected out of 12 size combination(3 women per 75A size) and then, their brassiere fitting was tested. As a result, the fronts of the basic patterns were found to have such problems as undone front center, poor levelling of upper cups bottom line or lower cups top line, poor shape of upper cups outside top line and shoulder strip position. On the other hand, n the rear side of the basic patterns, the central part of the wing was slightly lifted, while the wing width and straps interval did not befit the full-cup brassiere. The result of this first brassiere fitting test showed that the functionality and aesthetics of the basic pattern brassieres were more or less satisfactory, and thus, the problems were address for the second test. In the second test, the aesthetics, breast-shaping effect and functionality of the basic pattern brassieres were much improved. 2. The basic patterns of adult womens brassieres were characterized by a round cup wired as well as a full cup embracing the entire breasts. Each basic pattern which consisted of upper and lower cups was shaped \"straight(-)\". The basic sizes adopted at the first design stage (see fig. 1-2) was 75A of which was designed as upper foundation basic pattern. At the second stage, the upper body foundation pattern were used to design lower cup, upper cup, front panel and wing in their order.(see fig. 3-5, fig. 8)5, fig. 8)

  • PDF

$DMD^{TM}$를 이용한 마이크로 광 조형 시스템에서 다이나믹 패턴 생성 및 구동에 관한 연구 (A Study on Generation and Operation of Dynamic Pattern at Micro-stereolithography using $DMD^{TM}$)

  • 김현수;최재원;하영명;권변호;원명호;이석희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1214-1218
    • /
    • 2005
  • As demands for precision parts are increased, existing methods to fabricate them such as MEMS, LIGA technology have the technical limitations like high precision, high functionality and ultra miniaturization. A micro-stereolithography technology based on $DMD^{TM}$(Digital Micromirror Device) can meet these demands. In this technology, STL file is the standard format as the same of conventional rapid prototyping system, and 3D part is fabricated by stacking layers that are sliced as 2D section from STL file. Whereas in conventional method, the resin surface is cured as scanning laser beam spot according to the section shape, but in this research, we use integral process which enables to cure the resin surface at one time. In this paper, we deal with the dynamic pattern generation and $DMD^{TM}$ operation to fabricate micro structures. Firstly, we address effective slicing method of STL file, conversion to bitmap, and dynamic pattern generation. Secondly, we suggest $DMD^{TM}$ operation and optimal support manufacturing for $DMD^{TM}$ mounting. Thirdly, we examine the problems on continuous stacking layers, and their improvements in software aspects.

  • PDF

가스화와 소각 용융 조건에서 생성된 슬랙의 재활용성 분석 (Recyclability Analysis of Slags Obtained at Gasification and Incineration-Melting Conditions)

  • 윤용승;이계봉
    • 에너지공학
    • /
    • 제13권1호
    • /
    • pp.82-91
    • /
    • 2004
  • 석탄 및 하수슬러지 내에 함유된 무기물질을 환경적 측면에서 안정적인 물질로 재활용하기 위해서는 회재의 형태가 아닌 슬랙의 형태로 발생시키는 것이 한 방법이다. 가스화 반응에서 생성된 석탄 슬랙과 소각ㆍ용융과정에서 생성된 하수슬러지 슬랙의 특성을 분석하여, 재활용 측면에서 살펴보았다. 급냉을 시킨 슬랙들은 잘게 쪼개진 수 mm크기로 발생되었고, 함유된 미연탄소분은 모두 0.15% 이하였으며 슬랙의 구조는 대부분 무결정형인 특징을 보여주고 있었다. 분석 결과를 보면, 석탄 슬랙과 하수슬러지 슬랙 모두 중금속 성분이 용출되는 양은 국내기준치의 10배나 엄격한 일본기준보다도 훨씬 낮아서 재활용 물질로 활용하는 데에 문제가 없음을 알 수 있었다. 슬랙 내에 함유된 중금속 농도에서는 큰 차이가 있었는데, 향후 중금속 함량규제가 도입될 경우에는 두 슬랙 원료의 혼합 활용을 통해 중금속 함량 조절도 가능할 것이다.