• Title/Summary/Keyword: standard hook

Search Result 36, Processing Time 0.021 seconds

Performance Evaluation Test for Applying the Mechanical Development of the High-Strength Reinforcing Bars to the Nuclear Power Plant Structures (고강도철근 기계적정착의 원전구조물 적용을 위한 성능평가실험)

  • Lee, Byung-Soo;Bang, Chang-Joon;Lim, Sang-Joon;Kim, Seok-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.197-198
    • /
    • 2012
  • If the mechanical development be applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the re-bar yield strength and diameter. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

Structural Behavior of RC Columns with Mechanically Anchored Crossties under Cyclic Loading (기계적 정착된 전단보강근을 가진 RC 기둥의 구조적 거동)

  • Lee, Sung-Ho;Chun, Sung-Chul;Oh, Bo-Hwan;Nah, Hwan-Sean;Kim, Sang-Koo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.59-62
    • /
    • 2005
  • Seven columns laterally reinforced with either mechanically anchored crossties or conventional crossties under cyclic loading are tested. 4 columns are specimens for flexural strength and 3 columns are for shear strength. Main variable is anchorage types of crossties. Conventional hooks, 180$^{\circ}$ standard hook-mechanical anchorage and all mechanical anchorage type are used. The specimens are tested under 10$\%$ axial load of nominal axial capacity of the columns combined with increasing lateral load. From the flexure test, it is found that columns with mechanical anchorages exhibit superior performance in terms of ductility and energy dissipation. The crossties with mechanical anchorages reduce buckling length of longitudinal rebar. From the shear test, it is found that. 3 specimens exhibit almost the same strength, displacement, and shear failure mode at ductility factor =2.

  • PDF

The Technology Development for applying the High Strength Headed Deformed Bar to the Nuclear Power Plant Structures (원전구조물의 확대머리 고강도철근 적용기술 개발)

  • Lee, Byung-Soo;Bang, Chang-Joon;Lee, Han-Woo;Lim, Sang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.273-275
    • /
    • 2013
  • If the mechanical development is applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the yield strength and diameter of the re-bar. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

Design Considerations and Pull-Out Behavior of Mechanical Anchor of Reinforcement (철근 기계적 정착장치의 설계 고려사항과 인발특성)

  • 천성철;김대영
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.593-601
    • /
    • 2001
  • In RC structure, sufficient anchorage of reinforcement is necessary for the member to produce the full strength. Generally, conventional standard hook is used for the reinforcement's anchorage. However, the use of standard hook results in steel congestion, making fabrication and construction difficult. Mechanical anchor offers a potential solution to these problems and may also ease fabrication, construction and concrete placement. In this paper, the required characteristics and the design considerations of mechanical anchor were studied. Also, the mechanical anchor was designed according to the requirements. To investigate the pull-out behavior and properness of mechanical anchorage, pull-out tests were performed. The parameters of tests were embedment length, diameter of reinforcement, concrete compressive strength, and spacing of reinforcements. The strengths of mechanical anchor were consistent with the predictions by CCD method. The slip between mechanical anchor and concrete could be controlled under 0.2mm. Therefore, the mechanical anchor with adequate embedment could be used for reinforcement's anchorage. However, it was observed that the strength of mechanical anchors with short spacing of reinforcements was greatly reduced. To apply the mechanical anchor in practice (e.g. anchorage of the beams reinforcements in beam-column joint), other effects that affect the mechanical anchor mechanism, such as confinement effect of adjacent member from frame action or effects of shear reinforcement, should be considered.

Arthroscopic Capsular Repair without Relaying Sutures: 'Simple Sewing Technique'

  • Kim, Hyungsuk;Song, Hyun Seok;Kang, Seung Gu;Han, Sung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.3
    • /
    • pp.146-148
    • /
    • 2019
  • We report a simple technique for repairing capsular tear, using only a hook-like, cannulated instrument and braided sutures without relaying steps. A No. 2 braided suture is passed through the lumen of the instrument. Under direct arthroscopic view, the tip of the instrument is passed through the side of the capsule that has previously been separated with the probe. One end of the suture is retrieved with a grasper through a separate portal. The tip is moved back without withdrawing through the skin, and reinserted into the other side of the capsule. Holding the end retrieved earlier, the other end of the suture is retrieved with a suture retriever. After complete removal of the instrument, the suture is tied through a cannula using the standard knot tying techniques. The same procedures are repeated for other required knots.

Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction

  • Yang, Min Jae;Kim, Jin Hong;Hwang, Jae Chul;Yoo, Byung Moo;Lee, Sang Hyub;Ryu, Ji Kon;Kim, Yong-Tae;Woo, Sang Myung;Lee, Woo Jin;Jeong, Seok;Lee, Don Haeng
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.722-727
    • /
    • 2018
  • Background/Aims: Although endoscopic bilateral stent-instent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Methods: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Results: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Conclusions: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

A FINITE ELEMENT AND STRAIN GAUGE ANALYSIS ON THE DISPLACEMENT OF CRANIOFACIAL COMPLEX WITH CERVICAL HEADGEAR (경부고정(頸部固定) headgear 사용시(使用時) 안면두개골(顔面頭蓋骨)의 변위(變位)에 관(關)한 장력계측법(張力計測法) 및 유한요소법적(有限要素法的) 연구(硏究))

  • Kim, Hyun-Soon;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.17 no.2
    • /
    • pp.185-200
    • /
    • 1987
  • This paper was undertaken to observe the displacement of craniofacial complex with cervical headgear and to compare narrowing or widening effect of palate by use of contraction or expansion face-bow, respectively. The 3-dimensional finite element method(FEM) was used for a mathematical model composed of 597 nodes and 790 elements and an electrical resistance strain gauge investigation was performed to validate the finite element model. The outer bow of cervical headgear was adjusted to be placed below the occlusal plane by $25^{\circ}$ and met the midsagittal plane by $40^{\circ}$, and was loaded 1kg on each right and left hook toward posterior direction. The results were as follows 1. Generally, the maxillary teeth and facial bone were displaced in posterior, medial and downward direction. 2. It was the maxillary 2nd bicuspid that moved bodily. 3. The craniofacial complex rotated in a clockwise direction around the rotating axis which lay from the most posterior and lowest point connecting nasal crest of maxillary bone and vomer, progressively toward a more posterior, lateral and upward direction, anterior and upper area of pterygomaxillary fissure, base of medial pterygoid plate and laterally to the contact area of zygomatic arch with squamous part of temporal bone. 4. No contraction effect was observed by contraction face-bow when compared to the standard face-bow. 5. In case of expansion face-bow, the areas of maxillary 2nd bicuspid, molars and palate were expanded remarkably.

  • PDF

Cephalometric Angular Measurements of the Mandible Using Three-Dimensional Computed Tomography Scans in Koreans

  • Kim, Yong Hyun;Kang, Seok Joo;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.32-37
    • /
    • 2016
  • Background We conducted this study to analyze the values of the key cephalometric angular measurements of the mandible using 3-dimensional (3D) computed tomography scans. Methods In the 106 enrolled patients, a 3D cephalometric analysis was performed to measure the angular variables of the mandible. These values were compared between the two sides and between the two sexes. Results The frontal measurements revealed that the mandibular body curve angle was larger on the left (Lt) side (right [Rt], $141.24{\pm}7.54$; Lt, $142.68{\pm}6.94$; P=0.002) and the gonial angle was larger on the right side (Rt, $134.37{\pm}8.44$; Lt, $131.54{\pm}7.14$; P<0.001). The sagittal measurements showed that the gonial angle was larger on the right side (Rt, $134.37{\pm}8.44$; Lt, $131.54{\pm}7.14$; P>0.05). Further, the transverse measurements revealed that the mandibular body curve angle was larger on the right side (Rt, $140.28{\pm}7.05$; Lt, $137.56{\pm}6.23$; P<0.001). Conclusions These results provide an average of the mandibular angular measurements for the Korean population, establishing a standard for determining surgical patient groups and outcome evaluations in the field of mandible contour surgery.

Damages of minarets during Erciş and Edremit Earthquakes, 2011 in Turkey

  • Bayraktar, Alemdar;Altunisik, Ahmet Can;Muvafik, Murat
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.479-499
    • /
    • 2014
  • This paper illustrates the damages of reinforced concrete and masonry minarets during October 23 (Erciş) and November 9 (Edremit), 2011 Van earthquakes in Turkey. Erciş and Edremit are townships located 90km and 18km from Van city center in Turkey, respectively. Ground accelerations and response spectrums for these earthquakes are given in this paper. A total of 63 reinforced concrete and masonry minarets are heavily damaged or collapsed in the city center and villages nearby after both earthquakes. Because of the fact that there is no Turkish standard and specification directly related to design of minarets, nearly all of the constructions are carried out by workers using only their own technical knowledge. So, all of the non-engineering reinforced concrete and masonry minarets completely collapsed or damaged heavily. From the study, it is seen that the damages are due to several reasons such as site effect, location, and length of the fault, reduction in cross section and formation of the discontinuity, use of plain reinforcement steel, use of concrete with insufficient strength, existence of short lap splices and incorrect end hook angle, larger mass and stiffness concentrations on some region, longitudinal reinforcements discontinuity, cracks at the cylindrical body, and damage of spire and end ornament. In addition to these reasons, the two earthquakes hit the minarets within seventeen days, causing progressive damage. So, the existing design and construction practices should be improved to provide sufficient earthquake performance. Also, it is recommended that there should be a safe distance between the minaret and surrounding structures to reduce the loose of life after earthquake.

Structural Behavior of Wall-Type Structure with the Application of Slip-Form System (슬립폼 공법으로 건설된 벽식 구조의 거동에 관한 연구)

  • 문정호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.4
    • /
    • pp.157-168
    • /
    • 1995
  • The structural performance of Slip-Form system was examined to make use of many advantages of fast construction and high quality c0ncret.e. However, the separate cor~struction of wall and slabs may cause some weaknesses around the wall-slab connection region. Thus, the purpose of the study is to examine the structural performance of wall-type structure constructed by Slip-Form method and to develop an efficient connection system between wall and slabs. In order to investigate the system, 7 wall specimens and 8 wall-slab joint specimens were tested and the experimental results were compared with the design equations and theoretical analysis. A satisfactory performance was obtained from the wall specimen tests. However, wall-slab joint specimens with rebar connection materials I Ilalfen] were shown that. the strength of' wall should be checked during design porocess.