• 제목/요약/키워드: standard errors

검색결과 1,000건 처리시간 0.027초

Calibration and Uncertainty Analysis of Sample-Time Error on High Jitter of Samplers

  • Cho, Chihyun;Lee, Joo-Gwang;Kang, Tae-Weon;Kang, No-Weon
    • Journal of electromagnetic engineering and science
    • /
    • 제18권3호
    • /
    • pp.169-174
    • /
    • 2018
  • In this paper, we propose an estimation method using multiple in-phase and quadrature (IQ) signals of different frequencies to evaluate the sample-time errors in the sampling oscilloscope. The estimator is implemented by ODRPACK, and a novel iteration scheme is applied to achieve fast convergence without any prior information. Monte-Carlo simulation is conducted to confirm the proposed method. It clearly shows that the multiple IQ approach achieves more accurate results compared to the conventional method. Finally, the criteria for the frequency selection and the signal capture time are investigated.

전류변성기 비교측정 장치의 현장 평가기술 (On-Site Evaluation Technique of Current Transformer Comparator System)

  • 정재갑;이상화;권성원;강전홍;김명수
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.926-932
    • /
    • 2007
  • A recently developed methods for on-site calibration of the current transformer (CT) comparator system have been reviewed in the paper. The method utilizes several traveling standards, which consist of the CT, non-reactive standard resistors, wide ratio error CT, and shunt resistors. The traveling CT is used for absolute evaluation of a standard CT belonging to industry. The non-reactive standard resistors and a wide ratio error CT are used for the linearity check of errors in the current comparator. The shunt resistors are used for evaluation of CT burden of industry.

66kV급 전압변성기 비교측정 장치의 현장 평가설비 구축 (Construction of On-Site Calibration Facilities of 66 kV Voltage Transformer Comparator System)

  • 정재갑;이상화;권성원;김명수
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1268-1274
    • /
    • 2007
  • A recently developed methods for the on-site calibration of the voltage transformer (VT) comparator system have been reviewed in the paper. The method utilizes the several traveling standards consisting of the VT, the non-reactive standard resistors, the wide ratio error VT, and the decade resistors. The VT is used for the absolute evaluation of a standard VT belonging to the industry. The non-reactive standard resistor and wide ratio error VT are used for the linearity check of errors in the voltage comparator of the industry. The decade resistors are used for evaluation of a VT burden of the industry.

DEVELOPMENT OF A NON-STANDARD FINITE DIFFERENCE METHOD FOR SOLVING A FRACTIONAL DECAY MODEL

  • SAID AL KATHIRI;EIHAB BASHIER;NUR NADIAH ABD HAMID;NORSHAFIRA RAMLI
    • Journal of applied mathematics & informatics
    • /
    • 제42권3호
    • /
    • pp.695-708
    • /
    • 2024
  • In this paper we present a non-standard finite difference method for solving a fractional decay model. The proposed NSFDM is constructed by incorporating a non-standard denominator function, resulting in an explicit numerical scheme as easy as the conventional Euler method, but it provides very accurate solutions and has unconditional stability. Two examples from the literature are presented to demonstrate the performance of the proposed numerical scheme, which is compared to three methods from the literature. It is found that the method's estimated errors are extremely minimal, such as within the machine precision.

Low versus standard central venous pressure during laparoscopic liver resection: A systematic review, meta-analysis and trial sequential analysis

  • Mina Stephanos;Christopher M. B. Stewart;Ameen Mahmood;Christopher Brown;Shahin Hajibandeh;Shahab Hajibandeh;Thomas Satyadas
    • 한국간담췌외과학회지
    • /
    • 제28권2호
    • /
    • pp.115-124
    • /
    • 2024
  • To compare the outcomes of low central venous pressure (CVP) to standard CVP during laparoscopic liver resection. The study design was a systematic review following the PRISMA statement standards. The available literature was searched to identify all studies comparing low CVP with standard CVP in patients undergoing laparoscopic liver resection. The outcomes included intraoperative blood loss (primary outcome), need for blood transfusion, mean arterial pressure, operative time, Pringle time, and total complications. Random-effects modelling was applied for analyses. Type I and type II errors were assessed by trial sequential analysis (TSA). A total of 8 studies including 682 patients were included (low CVP group, 342; standard CVP group, 340). Low CVP reduced intraoperative blood loss during laparoscopic liver resection (mean difference [MD], -193.49 mL; 95% confidence interval [CI], -339.86 to -47.12; p = 0.01). However, low CVP did not have any effect on blood transfusion requirement (odds ratio [OR], 0.54; 95% CI, 0.28-1.03; p = 0.06), mean arterial pressure (MD, -1.55 mm Hg; 95% CI, -3.85-0.75; p = 0.19), Pringle time (MD, -0.99 minutes; 95% CI, -5.82-3.84; p = 0.69), operative time (MD, -16.38 minutes; 95% CI, -36.68-3.39; p = 0.11), or total complications (OR, 1.92; 95% CI, 0.97-3.80; p = 0.06). TSA suggested that the meta-analysis for the primary outcome was not subject to type I or II errors. Low CVP may reduce intraoperative blood loss during laparoscopic liver resection (moderate certainty); however, this may not translate into shorter operative time, shorter Pringle time, or less need for blood transfusion. Randomized controlled trials with larger sample sizes will provide more robust evidence.

SOME NOTES ON PHOTOMETRIC OBSERVATIONS: PHOTOELECTRIC PHOTOMETRIC OBSERVATIONS (I)

  • Lee, See-Woo
    • 천문학회지
    • /
    • 제10권1호
    • /
    • pp.31-38
    • /
    • 1977
  • To reduce the instrumental and calibration errors in the photoelectric photometry as much as possible it is necessary to select the optimum photocell voltage and energy attenaution and to observe as many standard stars as possible over the wide range of color, spectral type and air mass.

  • PDF

표준 색공간을 이용한 비표준 디스플레이의 색 보정 방법 (Color Correction Method of Non-standard Display Using Standard Color Space)

  • 김은수
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2151-2157
    • /
    • 2015
  • 색 정보 전달의 호환성을 위해 채택된 sRGB 색공간은 수많은 컴퓨터 시스템 및 주변 멀티미디어 장치들에 효율적인 색 정보 전달을 가능하게 한 표준이다. 하지만 현재 우리가 일반적으로 사용하고 있는 디스플레이 모니터는 sRGB의 표준과 다른 비 표준 삼원색과 감마 특성을 가지고 있다. 본 논문에서는 비표준 디스플레이를 sRGB 표준의 화상 색에 좀 더 가까운 색을 재현하기 위한 오차 보정 행렬을 제안한다. 제안한 색도 오차 보정 행렬을 이용한 방법을 적용한 실험 결과, 비 표준 디스플레이에 재현된 영상에서의 색 재현 오차가 감소하는 것을 확인할 수 있다.

"침구경험방(鍼灸經驗方)" "와혈(訛穴)"의 취혈법(取穴法) 분석에 따른 현대적 적용 연구 (An analytic study of acupoint locations described in "WaHyul" of "ChimGuKyungHumBang" and their modern application)

  • 이연희;차웅석;김남일;박히준;안상우
    • Korean Journal of Acupuncture
    • /
    • 제25권4호
    • /
    • pp.31-47
    • /
    • 2008
  • Objectives : The objective of this study is to apply the contents of "WaHyul(訛穴 : The errors of acupoint locations"of "ChimGuKyungHumBang" to modern acupoint locations. Methods : The text of "WaHyul" was closely examined and analyzed. "WHO standard acupuncture point locations in the western pacific region" was reviewed based on its contents. Results : According to the analysis, the correct 少商(LU11) was mentioned as a spot appropriately distanced from the corner of the nail root under the skin. This is the most accurate and reasonable synthesis of other related texts. Furthermore, the necessity of defining the locations of all the well points was also emphasized and their locations were mentioned that could be located by the same method. There is no further discussion of other acupoints apart from descriptions of their locations from other texts. Some parts that were pointed out as common errors included not only commonly made mistakes, but errors made in acupuncture texts as were true for 神門(HT7) and 肩井(GB21). The standards of 少商(LU11), 合谷(LI4) and 足三里(ST36) presented in the WHO Standardization are not only similar to what 「WaHyul」 indicated as errors in acupoint locations, but also deviate other acupuncture texts; appropriate corrections must be made. The standard of 肩井(GB21) presents a new acupoint locating method never mentioned before in received classic acupuncture texts and so a rediscussion is in need. Other standards, such as the 絶骨(GB39), had some points of controversy, yet somewhat incomplete while HT7 did not go beyond the bounds of "WaHyul". Conclusions : "WaHyul" can be used to revise WHO standards, and has practical value in modern acupoint locating.

  • PDF

Vision-based Automatic System for Non-contact Measurement of Morphometric Characteristics of Flatfish

  • Jeong, Seong-Jae;Yang, Yong-Su;Lee, Kyounghoon;Kang, Jun-Gu;Lee, Dong-Gil
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1194-1201
    • /
    • 2013
  • This paper introduces a vision-based automatic system (VAMS) for non-contact measurement of morphometric characteristics of flatfish, such as total length (TL), body width (BW), height (H), and weight (W). The H and W are simply measured by a laser displacement and a load cell, respectively. The TL and BW are measured by a proposed morphological image processing algorithm. The proposed algorithm cans measurement, when the tail of flatfish is deformed, and when it is randomly oriented. In the experiment, the average and maximum measurement errors were recorded, and standard deviations and coefficients of variation (CVs) for the measurements were calculated. From those results, when flatfish the TL measurements had an average of 266.844 mm, a standard deviation of 0.351 mm, a CV of 0.131%, and a maximum error of 0.87 mm with straightened flatfish ($TL_A$ : 267 mm, $BW_A$ : 141 mm), and when flatfish of different sizes were measured, the errors in the TL and BW measurements were both about 0.2 %. Using a single conveyor, the VAMS can process up to 900 fishes per hour. Moreover, it can measure morphometric characteristics of flatfish with a TL of up to 500 mm.