• Title/Summary/Keyword: standard comparison

Search Result 3,054, Processing Time 0.032 seconds

전류변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 현장 평가기술 (On-Site Evaluation Technique of Linearity for Ratio Error and Phase Angle Error of Current Transformer Comparison Measurement Equipment)

  • 정재갑;권성원;이상화;강전홍;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.313-316
    • /
    • 2006
  • A method for evaluation of the linearity of both the ratio error and phase angle error in the current transformer(CT) comparison measurement equipment has been developed by employing the standard resistors with negligible AC-DC resistance difference less than $10^{-5}$. The non-reactive standard resistors for the linearity check of the system are used as the external burden connected with the secondary of CT under test. These burdens consist of nine standard resistors, with the nominal resistance of $0.01{\Omega},\;0.1{\Omega},\;0.2{\Omega},\;0.4{\Omega},\;0.6{\Omega},\;1{\Omega},\;2{\Omega},\;4{\Omega}$, and $10{\Omega}$. For linearity check, the developed method has been applied in the CT comparison measurement equipment belonging to the industry.

한국과 중국의 콘크리트용 화학 혼화제 품질 규정 비교 (Comparison of Quality Standards of Chemical Admixtures for Concrete between Korea and China)

  • 후윈야오;임군수;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.97-98
    • /
    • 2023
  • In this study, comparison of the quality standard of chemical admixtures between Korea and China is conducted. It is classified into three types of water reducing agents: standard, delayed, and accelerated according to the sensitivity and strength improvement of the sensitivity and strength of the agent. However, Chinese standards classify reducing agents only as standard, high efficiency, and high performance, and do not add AE agents into water reducing agent. On the other hand, that of Korea has a classification regulation for reducing agents added with AE agents.

  • PDF

Comparison of the Standard Floor Impact Sound with Living Impact Source by Subjective Evaluation

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.39-48
    • /
    • 2014
  • In the previous test, the verification of the standard floor impact source was carried out comparing the physical characteristics with living impact sources. The result was appeared the validation of the standard impact source was very low because of differences of physical characteristics. This study aims to evaluate annoyance and loudness of standard impact source which is used for the measurement of floor impact sound, and to compare the annoyance and loudness of living impact sources which are produced in real life. The impact sources considered are tapping machine, tire and impact ball as standard sources, and nine real sources which were chosen from the existing researches. The result showed differences of annoyance and loudness between standard impact sources and living impact sources, which means the standard impact sources may rate the performance of floor system inappropriately. In the future, the rating method should be examined how the standard impact sources are similar with real sources in the point of rating the performance of floor system.

열탈착 방식을 연계한 GC/PFPD 시스템으로의 주입방식 차에 따른 악취황 성분의 검량특성: 주입부피 대비 주입농도의 고정방식 간 비교연구 (Changes in GC/PFPD Sensitivity in Relation with a Thermal Desorbing Technique for the Analysis of Sulfur Compounds: Comparison of Fixed Standard Concentration(FSC) vs Fixed Standard Volume(FSV))

  • 이기한;김기현
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2007년도 추계학술대회 논문집
    • /
    • pp.106-108
    • /
    • 2007
  • PDF

240 kV 고전압 변성기 국가표준 시스템 구축 (Establishment of National Standard System for 240 kV High Voltage Transformer)

  • 정재갑;권성원;이상화;강전홍;김명수;한상길;김윤형;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.164-169
    • /
    • 2008
  • National standard system for calibrating voltage transformer(VT) up to primary voltage of 240 kV have been established in 2005. The system consists of voltage source, regulating unit, VT testing unit, standard VT, VT under test and VT burden. To verify and validate the performance for 240 kV VT calibration system, the comparison with the National Measurement Institute of Australia(NMIA) has been performed using same VTs. The comparison results of the VTs mesured at the Korea Research Institute of Stansdards and Science(KRISS) are consistent with those measured at NMIA within 0.002 % for ratio error and 0.14 min for phase displacement in the primary voltage ranges of Vp = 3300 V - 22000 V with a secondary voltage of Vs = 110 V.

국내외 학교시설 녹색 건축 인증제도의 비교분석에 관한 기초연구 -G-SEED와 LEED, BREEAM을 중심으로- (A Study on Comparing and Analyzing Domestic and Foreign Green Building Certification Criteria for School Facility -Focused on the G-SEED and LEED, BREEAM-)

  • 이종국
    • 교육녹색환경연구
    • /
    • 제13권3호
    • /
    • pp.15-22
    • /
    • 2014
  • Proceeded with a research with basic data about the qualification standard improvement scheme about the environment school architecture in which a comparison analyze the specialized field of BREEAM system of LEED of the hit environment building qualification standard G-SEED of the domestic and U.S Green Building Counci evaluated with the certification system of the world top class and Building Research Establish, essential item, and mark distribution and weight in this study at this and which I hit with a domestic afterward. The school facility with a hub among the equipment receiving the hit environmental qualification standard, and the range of this research does LEED of the domestic green building certification system February is revised in 2013 G-SEED and which US and BREEAM in UK with a range. The way of the research checked the environment school building certification system and situation hit home and abroad, and a comparison analyze the division of the specialized field of each country qualification standard, essential item, and mark distribution and weight.

헬륨 투과형 표준리크 교정장치 개발 (Development of Calibration System of Helium Permeation Type Standard Leaks)

  • 홍승수;임인태;신용현
    • 한국진공학회지
    • /
    • 제15권4호
    • /
    • pp.347-353
    • /
    • 2006
  • 국제도량형위원회의 질량 및 관련량 자문위원회 (CCM)가 주관하는 헬륨 투과형 표준리크(standard leak) 핵심측정표준 국제비교 (key comparison, KC)에 참여하기 위하여 기존의 정압형 리크표준기에 porous plug를 추가하여 측정범위를 $10^{-6}$ Pa L/s 까지 확장한 헬륨 미세리크 표준기를 개발하였다. 이를 위해 헬륨 기체에 대한 고진공 및 초고진공 표준기의 압력비와 porous plug의 콘덕턴스를 새롭게 측정하였으며, 개발된 장치를 이용하여 명목 값이 $5.6{\times}10^{-4}$ Pa L/s 인 투과형 표준리크를 직접 교정한 결과 표준기와 차이가 11.1 % 임을 알 수 있었다.

핵심국제비교용 물의 삼중점 셀 제작과 비교 실험 및 불확도 평가 (Construction and Comparison Measurement of Triple Point Water Cells for using Key Comparison and Evaluation of Uncertainty)

  • 강기훈;김용규;감기술
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.114-120
    • /
    • 2004
  • The $Comet{\acute{e}}$ Consultatif de $Thermom{\acute{e}}trie$ (CCT) under the Comete International des Poids et Measures (CIPM) has decided to perform the Key Comparison (KC) for triple point of water cells used as a reference fixed point of thermometry at the 21st meeting held at November 2001, and the Bureau International des Poids et Measures (BIPM) has been nominated as a KC coordinator. According to the KC protocol prepared by BIPM, KRISS performed the KC experiments and evaluate a uncertainty. The temperature difference between two reference cells for the Korea Research Institute of Standards and Science (KRISS) and a test cell for the transfer standard, which is moved to BIPM was 0.024 mK and the combined standard uncertainty evaluated 0.055 mK.

충격전압 재단과 측정을 위한 보상회로에 관한 연구 (A Study on the Compensation Method in the Measuring System for Chopped Lightning Impulse)

  • 김익수;김영배;김진기;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1895-1897
    • /
    • 1996
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard (IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Comparison tests of dividers for chopped lightning impulse measurement were rallied out by KERI. The 700kV shielded resisitive divider with and without compensation element were done comparison test with 300kV PTB divider which have the similar charateristics as that were circulated among the laboratories. This paper reports on the calculation results of response charateristics obtained by EMTP and the comparison test results with chopped lightning impulse voltages from 150kV to 250kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF