• 제목/요약/키워드: stand-by mode

검색결과 101건 처리시간 0.028초

수동대기모드를 고려한 셋톱박스 모드전환 기술의 에너지 절감 성능 분석 (Power consumption evaluation of Set-top box mode transition scheme considering passive stand-by mode)

  • 김용호;김훈
    • 정보통신설비학회논문지
    • /
    • 제10권4호
    • /
    • pp.135-142
    • /
    • 2011
  • This paper proposes a performance evaluation method for power consumption of set-top box (STB) stand-by mode transition schemes. A stand-by mode transition scheme characterizes the timing of mode transition. The timing of mode transition affects the duration of stand-by mode operation, and the power consumptions of STB as well. Recently a fast stand-by mode transition scheme (FMT) has been proposed based on user input for selecting the device to be connected to TV. In this paper, we evaluate power consumption of FMT and a conventional mode transition scheme. For the computation of the duration of stand-by mode operation, the user input events are modeled as Poisson process. Simulation results based on the modeling reveals that the proposed scheme is more effective in power saving than the conventional scheme by up to 30%.

  • PDF

비선형부하에 의해 발생하는 고조파 보상을 위한 독립형 또는 계통연계형 인버터 제어기 설계 (Controller Design of Stand-Alone or Grid-Connected Inverter to Compensate Harmonics Caused by Nonlinear Load)

  • 신찬호;임경배;;최재호
    • 전력전자학회논문지
    • /
    • 제22권5호
    • /
    • pp.440-448
    • /
    • 2017
  • This paper proposes a controller design of a distributed source inverter in stand-alone mode or grid-connected mode to compensate the current or voltage harmonics caused by local nonlinear load. The PR-based multi loop controller has been used to improve the dynamic performance of the system and to compensate the output voltage or grid current harmonics. The multi-loop controller consists of an outer current controller and an inner voltage controller for the output voltage control in stand-alone mode. In grid-connected mode, an outer current controller is added to the output voltage controller for the grid current control. The design performance of each controller is described through the Root locus and Bode plot of the transfer functions. The validity of the proposed control algorithm and design parameters has been verified through the PSiM simulation and experimental results.

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

인버터 시스템과 상용 전력 계통과의 병렬 운전에 관한 연구 (A Study on Parallel Operation Between Inverter System and Utility Line)

  • 천희영;박귀태;유지윤;안호균
    • 대한전기학회논문지
    • /
    • 제41권4호
    • /
    • pp.369-378
    • /
    • 1992
  • This paper proposes a utility parallel processing inverter system, which consists of a voltage source PWM inverter, isolation transformer and a reactor linking the inverter to utility line. This system realizes following functions : (1) voltage phase frequency and amplitude synchronization between inverter and utility line at stand-alone mode. (2) current phase synchronization between inverter and load at parallel mode. Therefore, despite sudden increase in load current over setting point at stand-alone mode, inverter system can be transferred into parallel mode immediately without transient current. Furthermore, high frequency(18KHz) PWM control and sinusoidal filtering improve the inverter output waveform by eliminating high order harmonic components as well as low order. As a switching device, IGBT is used for high frequency switching and large current capacity.

  • PDF

불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법 (Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load)

  • 이우종;조종민;차한주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

임상도 작성시 정밀 영급분석기법 연구 (Analysis Methology of Detailed Stand Age Classes in Forest Type Map)

  • 김정호
    • 한국환경과학회지
    • /
    • 제17권6호
    • /
    • pp.647-655
    • /
    • 2008
  • The purpose of the study is to find the problems related to the current state of the stand age classes and the method of calculating it defined in the existing forest type map and propose the more accurate method of calculating the stand age classes. The object for the study was selected as the forest scattered around the Geesan village Paju city in Kyunggi province. For the accurate method of calculating the stand age classes, such items as, the type of actual vegetation, establishment of grid-type standard area scaled down at the level of the 5% of the actual area, the types, number, DBH and age of tree found by the plots, were investigated. It was found out actual vegetation was divided into the total 24 types and the 20 types of them belonged to the growing tree areas. As the plots, the 125 places(unit area: $400m^2$) were established the types of the trees found were distributed in the range where the minimum was 1 type, the maximum was 9, the mean was $4.4{\pm}1.5$, and the mode was 4 types. The number of the trees found was distributed in the range where the minimum was 17, the maximum was 125, the mean was $4.4{\pm}1.5$, and the mode was 70. In the DBH, the minimum was 6 cm, the maximum was 30 cm, the mean was 13 cm and the mode was 10 cm. As the result of measuring the age of the 5 trees corresponding to the value of the mode in DBH, selected among the dominant species by the plots, less than 20 years was 17 places, the 115 places were included in the range from 21 to 30 years, and more than 31 years was the 6 places.

전환제어법칙 설계 및 검증에 관한 연구 (A Study on the Design and Validation of Switching Control Law)

  • 김종섭
    • 제어로봇시스템학회논문지
    • /
    • 제17권1호
    • /
    • pp.54-60
    • /
    • 2011
  • The flight control law designed for prototype aircraft often leads to degraded stability and performance, although developed control law verify by non-real time simulation and pilot based evaluations. Therefore, the proper evaluation methods should be applied such that flight control law designed can be verified in real flight environment. The one proposed in this paper is IFS (In-Flight Simulator). Currently, this system has been implemented into the F-18 HARV (High Angle of Attack Research Vehicle), SU-27 and F-16 VISTA (Variable stability In flight Simulation Test Aircraft) programs. The IFS necessary switching control law such as fader logic and integrator stand-by mode to reduce abrupt transient and minimize the integrator effect for each flight control laws switching. This paper addresses the concept of switching mechanism with fader logic of "TFS (Transient Free Switch)" and stand-by mode of "feedback type" based on SSWM (Software Switching Mechanism). And the result of real-time pilot evaluation reveals that the aircraft is stable for inter-conversion of flight control laws and transient response is minimized.

신뢰성 개선을 위한 저전력 열연 복합식 단독경보형 감지기 개발 (Development of the Low Power Stand-Alone Smoke and Heat Detector for the Reliability Improvement)

  • 지승욱;김시국;이재진;김필영;이춘하
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.74-79
    • /
    • 2012
  • 본 논문은 2011년 개정된 "감지기 형식승인 및 검정기술기준"에 적합한 단독경보형 감지기 개발에 관한 연구이다. 변경된 내용의 가장 큰 특징은 전원이다. 10년 이상 사용 가능한 단독경보형 감지기를 개발하기 위해 나노전력기술이 사용된 저전력 마이크로컨트롤러를 사용하였다. 마이크로컨트롤러의 슬립모드를 활용하고, 저전력의 전원감시부, 열감지부 및 연기감지부를 제작하여 저전력 단독경보형 감지기를 개발하였다. 특히, 비화재보를 줄이기 위해 단독경보형 감지기는 열연 복합식으로 개발되었다. 사용자는 딥스위치를 이용하여 열감지모드 또는 열 연기감지모드로 동작형태를 선택할 수 있다. 마이크로컨트롤러가 지원하는 RS-485 통신기능을 활용하여 유선으로 단독경보형 감지기 간에 통신이 가능하도록 하였다. 이로써 화재발생시 보다 넓은 지역까지 경보를 알릴 수 있고 비화재보를 줄인 열연 복합식 단독경보형 감지기를 개발하였다.

분산모듈형 태양광 전력조절기의 독립운전 제어 (Control Method of Distributed-Module Type Photovoltaic Power Conditioners under Stand-alone Operation)

  • 서정원;박종후;김혜림
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.448-457
    • /
    • 2013
  • This paper proposes a control method under stand-alone operating mode for distributed-module type photovoltaic power conditioners. In conventional schemes, there are some problems of a controller saturation in the DC-link (or load) voltage controller when overly-heavy load, light load, and the generated PV power reduction occurs, as well as when a transition occurs from an overly-loaded to normal conditions. To overcome these problems, the proposed controller method switches the main control target from DC-link voltage to the maximum power point, which is closer to the stable operating point when it returns to normal operating conditions. For the analysis, a state-plane trajectory was given and the circuit analysis by PSIM simulation was done. For the verification, a prototype hardware with 110[W] and 50[W] dual photovoltaic modules has been implemented. From the results, it can be seen that PV power tracking is successfully done with the proposed method even under a stand-alone operation mode.

마이크로터빈발전시스템 독립운전을 위한 동적 모델링 (Dynamic Model of Microturbine Generation System for Stand-Alone Mode Operation)

  • 조재훈;홍원표
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.210-216
    • /
    • 2009
  • 마이크로그리드는 전력시스템의 계획 및 실시간 운영에 있어서 매우 큰 영향을 미치며 중요한 역할을 할 것으로 판단된다. 따라서 본 연구에서는 빌딩의 마이크로그이드의 중요한 마이크로소오스인 마이크로터빈 발전시스템의 Matlab/Simulink 모델과 전압-주파수제어기를 개발하였다. 또한 부하에 독립적으로 전원을 공급하기 위한 전력시스템을 구성, 모의를 통하여 MTG시스템의 특성을 분석하였다.