• Title/Summary/Keyword: stand characteristics

Search Result 543, Processing Time 0.028 seconds

Characteristics of Transitional Period of Korean Family and Family Policy (한국 가족의 전환기적 특성과 가족정책)

  • Lee, Seung-Mie;Song, Hye-Rim;Lee, Wan-Jung;Sung, Miai;Chin, Mee-Jung;Lee, Hyun-Ah
    • Journal of Families and Better Life
    • /
    • v.30 no.6
    • /
    • pp.183-199
    • /
    • 2012
  • Since the Framework Act on Healthy Families came into effect in 2005, family policy has become a primary field of social policy, and 'family' has emerged as an important keyword for solving Korean society's various phenomena and problems. In order to seek practical plans for reforming social policy through family policy, this thesis has analyzed the transitional characteristics of Korean families in relation to where Korean families currently stand and the situation they are facing. This thesis has also reviewed the content of family policy in the master plan of healthy families, the starting point of the actual family policy, and other related policies. It also has analyzed the key content of child care support policy. From these various analyses and discussions, this thesis has emphasized "family care" as the keyword of family policy, family effect analysis as the means of reinforcing family perspective, and family integrity for policy effectiveness.

A Dynamic Characteristics on Non-linear Voltage Electric Equipment under Voltage Sag (순간전압강하에 대한 비선형 저압전기기기의 동적특성)

  • Lee, Hyun-Chul;Jeong, Sung-Won;Gim, Jae-Hyeon;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.336-343
    • /
    • 2008
  • In this study, a transition of power quality was characterized by non-linear voltage electric equipments under voltage sag. The test was inputted voltage sag to IPC(Sag Generator) from AVR, and then to equipments by IPC which adjust voltage magnitude and duration. The load test which non-linear voltage electric equipments used PLC, Magnetic Contactor, SMPS, HID Lamp. The test result was different from each other according to a manufacturing companys, models, and equipments. PLC was greatly described to be stabilized voltage sag in case of no load then rated load. Magnetic Contactor was made a difference to phase angles on voltage sag, which was $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. HPD Lamp was described to be stabilized the sodium lamp, and to be unstabilized the metal hailed lamp. The test result was showed CBEMA curve that stand for evaluated responsiveness of voltage sag. This study was tested description to dynamic characteristics on non-linear voltage electric equipment under voltage sag. There was hoped that power system designed the essential particulars.

Phenological Studies of Deciduous Trees in the Cool Temperate Region of Japan

  • Jun, Kala;Hayashi, Ichiroku
    • Journal of Ecology and Environment
    • /
    • v.31 no.3
    • /
    • pp.193-200
    • /
    • 2008
  • We obtained quantitative information on leaf unfolding and leaf shedding by observing 45 species of cool temperate deciduous trees in an arboretum over 5 growing seasons. These trees were in leaf (the foliage period) for 207 days on average after 1 April; 50% of leaves had been shed by 192 days after 1 April. Duration from the start of leaf unfolding to 50% leaf shedding was 157 days on average. Leaf unfolding began 35 days on average after 1 April. For leaf unfolding to begin, a$ 51^{\circ}C{\cdot}day$ of cumulated daily mean air temperature above $5^{\circ}C$ from 1 January (modified Kira's warmth index) was needed. Fifty-nine days elapsed between initiation and the final stage of leaf unfolding. The period of net photosynthetic assimilation was 157 days. The species with succeeding- type leaf unfolding associated with the anemochore seed type dominated the early stage of succession, while the species with flush-type leaf unfolding tended to dominate the late stage of succession. Few species were found in regions where late frosts occur after the day when the cumulative temperature for leaf unfolding is achieved. Biological characteristics include time of leaf unfolding, which affects the life history of each species, so that each species occupies its own niche in the stand. We conclude that that leaf phenology, such as timing of leaf unfolding and leaf shedding, is one of the components of each species' ecological characteristics.

Effects of Stimulation Conditions and Waveforms on Muscle Contractile Characteristics

  • Song Tongjin;Khang Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • This study was designed to apply the stimulation system developed in our laboratory to investigate how the stimulation conditions affect the muscle contractile characteristics in the isometric condition as well as during the FES standing/walking. Four paraplegic and ten healthy subjects participated in this study, and their knee extensors were voluntary contracted or electrically stimulated to measure the muscle force and the fatigue index for different waveforms of the pulse train. We also investigated different combinations of the electrode positions during standing/walking. It was confirmed that continuous and high-frequency stimulation causes faster fatigue than intermittent and low-frequency stimulation. Fatigue resistance was higher around the optimal muscle length than at a stretched position in healthy subjects, whereas the opposite was observed in paralyzed subjects. The paired t-test results with the level of significance at 0.01 indicated that the sinusoidal waveform generated the largest torque among the four typical waveforms. Although statistically not very significant, the sinusoidal waveform also generated, in general, the highest fatigue resistance at an intensity level below the supramaximal stimulation. One of the paraplegic subject who participated in the standing/walking program can now stand up for 1 minute and 50 seconds with the knee extensors, and walk for about 5 minutes at the speed of 12m/sec.

A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser (리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘)

  • Kim, Seul-Ki;Kim, Eung-Sang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.5
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.

The Design Characteristics of Modern Children's Clothes - Focus on Children's Clothes for Girls From The 2006S/S-2010S/S Collections - (현대 아동복의 디자인 특성 분석 - 2006S/S~2010S/S 컬렉션의 여자 아동복를 중심으로 -)

  • Kong, Mi-Ran
    • Fashion & Textile Research Journal
    • /
    • v.14 no.3
    • /
    • pp.347-362
    • /
    • 2012
  • The analysis results of the characteristics of children's clothes for school girls from the 2006S/S-2010S/S collections reveal that the most frequent type of item composition was 2'PS & 3'PS. T-shirts were the popular kind of item for upper garments and pants for lower garments. The major silhouettes were H and A line. The predominant neckline was U, which was followed by camisole and V. The major collar styles were stand-up and flat. Chromatic colors were used more than achromatic ones and after white the most popular colors were blue, pink, red, black, navy, and green. The dominant color scheme was a two-color or three-color scheme. The percentage of solid and patterned material garments was the highest and the most popular pattern was flowers. The most popular style of garment had no decorative detail that was followed by one-item, two-item, and three-item decoration. The major kinds of decorative detail were frills, pleats, and prints.

Characteristics of Soil Groups Basd on the Development of Root Rot of Ginseng Seedlings (인삼 유묘 뿌리썩음병 진전에 따른 토양군별 특성)

  • 박규진;정후섭
    • Korean Journal Plant Pathology
    • /
    • v.13 no.1
    • /
    • pp.46-56
    • /
    • 1997
  • Based on the principal component analysis (PCA) of Richards' parameter estimates, ginseng field soils were grouped as the principal component 1 (PC1) and the principal component 2 (PC2). The microflora and physico-chemical characteristics of each soil group were compared to elucidate soil environmental factors affecting the disease development of root rot of ginseng seedling. Among 3 soil groups by PC1, there were differences in the populations of total fungi (TF) and Cylindrocarpon plus Fusarium (C+F), and the population ratio of Cylindrocarpon plus Fusarium to total fungi or total bacteria (C+F/TF, C+F/TB) in rhizoplane of ginseng seedlings, the population of total actinomycetes (TA) and the population ratio of total Fusarium to total actinomycetes (Fus/TA) in soil, and soil chemical properties (EC, NO3-N, K, Mn, ect.). Among 4 soil groups by PC2, there were differences in TF, C+F, TB, C+F/TF and C+F/TB in the rhizoplane, Trichoderma plus Gliocladium (T+G) in soil, and P2O5 content in soil. Especially, EC, NO3-N, K, K/Mg and Mn were positively correlated to PC1, and TA was negatively to PC1; however, TF, C+F, TB, C+F/TF and C+F/TB in the rhizoplane were significantly correlated to PC2 positively. On the other hand, microbes in the rhizoplane were not significantly correlated to the stand-missing rate (SMR), although TA and Fe/Mn were negatively correlated, and pH and Ca were positively correlated to SMR.

  • PDF

Effect of one way reinforced concrete slab characteristics on structural response under blast loading

  • Kee, Jung Hun;Park, Jong Yil;Seong, Joo Hyun
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.277-283
    • /
    • 2019
  • In evaluating explosion-protection capacity, safety distance is broadly accepted as the distance at which detonation of a given explosive causes acceptable structural damage. Safety distance can be calculated based on structural response under blast loading and damage criteria. For the applicability of the safety distance, the minimum required stand-off distance should be given when the explosive size is assumed. However, because of the nature of structures, structural details and material characteristics differ, which requires sensitivity analysis of the safety distance. This study examines the safety-distance sensitivity from structural and material property variations. For the safety-distance calculation, a blast analysis module based on the Kingery and Bulmash formula, a structural response module based on a Single Degree of Freedom model, and damage criteria based on a support rotation angle were prepared. Sensitivity analysis was conducted for the Reinforced Concrete one-way slab with different thicknesses, reinforcement ratios, reinforcement yield strengths, and concrete compressive strengths. It was shown that slab thickness has the most significant influence on both inertial force and flexure resistance, but the compressive strength of the concrete is not relevant.

An Electronic Step-Down Transformer with Voltage Stabilization Characteristics for Custom Power (전압 안정화 특성을 갖는 수용가용 전자식 강압형 변압기)

  • 최남섭;강정식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.423-426
    • /
    • 2001
  • In this paper, an electronic step-down transformer with output voltage stabilization characteristics is presented. The proposed electronic transformer has some advantages and features as follows: 1) It has 40 % weights lighter than that of commercial magnetic transformer, 2) It has output voltage stabilization characteristic with regulated output voltage over input variations, 3) It cab be operated as circuit breaker in the case of emergency, 4) It can be operated with so called soft starting function. Moreover, the electronic transformer may have stand-by power cutoff function and act as distortion compensator. This paper show the circuit diagram and present its features through various PSPICE simulations.

  • PDF

The Strength Characteristics By Freezing and Thawing of Controlled Low Strength Material Using Coal Ash (석탄회를 활용한 CLSM의 동결융해에 의한 강도 특성)

  • Hyun, Ho-Gyu;Kim, Sun-Tae;Jung, Hyuk-Sang;Chun, Byung-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.32-37
    • /
    • 2010
  • Recently, the land area for many people has been limited because of industrialization and modernization in Korea. The large-scale constructions like the reclamation development projects have been progressed to resolve this problem mentioned above. Therefore, as many of the usefulconstruction materials as possible are needed to perform the large-scale construction projects. Many studies for the utilization of pond ash which has a similar characteristic of sand have been conducted and there has been often occurred many structural problems on roadbed in winter. Therefore, the characteristics of the freezing and thawing for Controlled Low-Strength Material (CLSM) using pond ash were analyzed and evaluated by unconfined compressive strength test in this study. As a result of this study, it was confirmed that new CLSM using pond ash with cement (8.2% by weight)was able to stand for the freezing and thawing behavior.

  • PDF