• Title/Summary/Keyword: stack recovery

Search Result 38, Processing Time 0.03 seconds

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

Reduction of Thermal Radiation from Flare Stack by Flare Gas Recovery Unit (폐가스 회수장치를 이용한 플레어스택의 복사열 감소)

  • Lee, Heon-Seok;Lee, Dong-Heuk;Yoo, Jin-Hwan;Park, Chul-Hwan;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • During process operations, overpressure can be caused by operator's error or malfunction of the device. To prevent this overpressure, gas was released through blowdown system. Because most of released gases are the hydrocarbon mixture and have flammable and toxic properties, the gas is released after burning in flare stack. The increase of scale and complexity of plant requires higher or additional flare stacks. This study tried to solve this problem through flare gas recovery system.

A study on the run-time storage management for recursice and nested structure (Recursive nested 구조를 위한 run-time 기억장소 운영에 관한 연구)

  • 김영택;차윤경
    • 전기의세계
    • /
    • v.31 no.4
    • /
    • pp.281-287
    • /
    • 1982
  • PASCAL has a recursive nested structure and uses deep binding of identifiers. This paper studies the problems and techniques in storage management for PASCAL on the IBM 370 system, and presents run-time storage administration algorithms which use stack scheme and heap efficiently on the view of storage. The stack-scheme was used to implement the feature of recursive nested structure and the heap was used to implement the feature of the dynamic allocation procedure and pointer variable, allowing an additional dynamic storage recovery procedure.

  • PDF

An Out of Core Linear Direct Solution Method for Large Scale Structural Analysis (대규모 구조해석을 위한 보조기억장치 활용 선형 직접해법)

  • Kim, Min-Ki;Kim, Seung Jo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.6
    • /
    • pp.445-452
    • /
    • 2014
  • This paper discusses the multifrontal direct solution method with out of core storage for large scale structural analysis in a limited computing resource. Large scale structural analysis requires huge amount of memory space and computation, so out of core solution method is needed in limited computing resource. In this research, out of core multifrontal solution algorithm which utilize the small size of physical memory and minimize the amount of access of low speed out of core storage is introduced. Three ideas, which are stack space in lower trianglar part of square factorization matrix, inverse stack data structure and selective data caching and recovery by data block size, are proposed.

Steady and Dynamic Modeling of 3MW MCFC System Conceptual Design Using Parameter Interpolation Method (파라미터 보간법을 이용한 3MW급 MCFC 시스템의 정상 및 비정상 상태 설계)

  • Kim, Minki;Cho, Yinjung;Kim, Yunmi;Kang, Minkwan;Lee, Sanghoon;Kim, Jaesig
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.87.2-87.2
    • /
    • 2010
  • The steady and dynamic process model for an internal reforming molten carbonate fuel cell power plant is discussed in this paper. The dominant thermal and chemical dynamic processes are modeled for the stack module and balance-of-plant, including cathode gas preparation, heat recovery, heat loss (Each heat loss amount for the stack and MBOP is obtained from real plant data) and fuel processing. Based on dynamic model and control demand, PID controllers are designed in the whole system. By applying these controllers we can obtain temperature balance of stack and control system depending on changing steam to carbon ratio, air feed amount, and transient condition.

  • PDF

Operation Characteristics of 5 kW Class Proton-Exchange-Membrane Fuel Cell(PEMFC) Stack (5 kW급 고분자 전해질 연료전지 스택의 운전 특성)

  • Kim, Jae-Dong;Lee, Jung-Woon;Park, Dal-Ryung
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.51-54
    • /
    • 2007
  • 78-cell proton exchange membrane fuel cell(PEMFC) stack with an effective electrode area of $295cm^{2}$ were investigated its operational characteristics and effects of CO poisoning. When power output, 5.4 kW, was released at current density of $325mA/cm^{2}$ for 6 hours, stablility of each cell was showed the small deviation of 2.3%. Carbon monoxide is a conventional contaminant in the fuel obtained from reforming processes with an important influence on the performance of the PEMFC. The studies of continuous injection of CO presented (5-20 ppm) with the time gave information about poisoning and recovery processes of the stack.

  • PDF

The Implementation of Kernel Hardening Function by Recovering the Stack Frame of Malfunction Address on the Linux Operating System (리눅스 운영체제에서 주소값 오류시 스택 복구를 통한 커널 하드닝 기능 구현)

  • Jang, Seung-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.1
    • /
    • pp.173-180
    • /
    • 2007
  • This paper designs the kernel hardening function by recovering the kernel stack fame to reduce the system error or panic due to the kernel code error. The suggested kernel hardening function guarantees normal system operation by recovering the incorrect address of the kernel stack kernel. The suggesting kernel hardening mechanism is applied to the network module of Linux which is much using put. I experimented the kernel hardening function at the network module of the Linux by forcing panic code.

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.

Formation and Dispersion of Nitric Acid Vapor from Stack Flue Gas

  • Park, Mi Jeong;Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.96-107
    • /
    • 2014
  • Extreme recovery of the thermal energy from the combustion of flue gas may bring about early gas condensation resulting in the increased formation of nitric acid vapor. The behavior of the nitric acid formed inside the stack and in the atmosphere was investigated through a computer-aided simulation in this study. Low temperatures led to high conversion rates of the nitrogen oxide to nitric acid, according to the Arrhenius relationship. Larger acid plumes could be formed with the cooled flue gas at $40^{\circ}C$ than the present exiting gas at $115^{\circ}C$. The acid vapor plume of 0.1 ppm extended to 25 m wide and 200 m high. The wind, which had a seasonal local average of 3 m/s, expanded the influencing area to 170 m along the ground level. Its tail stretched 50 m longer at $40^{\circ}C$ than at $115^{\circ}C$. The emission concentration of the acid vapor in the summer season was a little lower than in the winter. However, a warm atmosphere facilitated the Brownian motion of the discharged flue gas, finally leading to more vigorous dispersion.

Treatment of organic dye solutions by electrodialysis

  • Majewska-Nowak, Katarzyna M.
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.203-214
    • /
    • 2013
  • Laboratory tests were performed to determine the efficiency of dye solution desalination by electrodialysis. The study involved anionic dye and mineral salt recovery by obtaining two streams from a salt and dye mixture - dye-rich solution and salt solution. A standard anion-exchange and cation-exchange membranes or monovalent selective anion-exchange membranes were used in the ED stack. It was found that the separation efficiency was strongly dependent on the dye molecular weight. The best results for standard ion-exchange membranes were achieved for the desalination of Direct Black solution. Furthermore, the obtained results implied that the application of monovalent selective anion-exchange membranes improved the recovery of dye and salt solutions - the dye concentration in the diluate remained constant irrespective of the molecular weight of anionic dyes, whereas the salt recovery remained very high (99.5%).