• 제목/요약/키워드: stack analysis

검색결과 479건 처리시간 0.029초

고기능성 생활용기 성형을 위한 대용량 스택금형 개발 (Development of large-capacity stack mold for the high-performance household case)

  • 신장순;김유진;정귀재;황순환;허영무;윤길상;정우철;서태일
    • Design & Manufacturing
    • /
    • 제2권3호
    • /
    • pp.28-31
    • /
    • 2008
  • In recent, the demand of high-productivity injection mold is increased because of the growth of international packaging market which is induced by an increase of population. The increase of productivity leads to the large-capacity injection molding machine and peripheral devices. For solving this problem, the stack mold which is based on the exsiting machine and device has researched in advanced countries actively. In this paper, as the preliminary research of stack mold development, the stack mold which has 2 level ${\times}4$ cavity was designed and fabricated. Besides, the motion and structural analysis were performed to verify the stability of developed stack mold.

  • PDF

초고층 복합건물의 연돌현상 가중요인과 저감방안 사례연구 (Case Study of Analysis of Problems and Minimizing Methods of Stack Effect in the Tall Complex Building)

  • 유정연;조동우;유기형;정차수;강소연;송규동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.363-368
    • /
    • 2006
  • The purpose of this case study is to analyze stack effect problems and to develop methods minimizing methods of stack effect in the tall complex building in cold climates. The main problems in the tall complex building occur in high-rise elevators. Such problems as elevator doors that do not close and exhaust airflows result in excessive pressure differences across elevator doors due to stack effect. Under the expected conditions causing these pressure differences, computer simulations with CONTAMW computer program and field measurements are performed in the tall complex building. The results are analyzed in architectural design aspects. With these analysis, the tall complex building design guidelines to minimize stack effect are proposed.

  • PDF

Evaluation of the Impacts of Stack Effect in High-Rise Buildings

  • Yang, In-Ho;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.91-103
    • /
    • 2003
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impacts on the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal air flow resistance. Therefore the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

초고층 건축물에서 급기가압제연이 연돌효과에 미치는 영향 (The Influence on the Stack effect that Pressure differential system to smoke control in High-rise buildings)

  • 임채현;박용환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.235-238
    • /
    • 2008
  • High-rise buildings with stack effect caused by the foreclosure, which significantly delayed the spread of a fire in effects of these stack effect driving force said. In this research on the stack effect of the lobby if the pressurization of the stairwell analysis of the pressure distribution of the CONTAMW. Overall, the pressurization of the lobby makes it stairwell amount of pressure(+) to the zone in pressure designed to prevent the spread of smoke control performance and found that, the way a normal state and sub-pressurization in the stairwell with stack effect of the turbulence Such as the formation of the upper flow, but, in the upper atmosphere with pressurization was formed by the underlying trend.

  • PDF

고층형 주거건물의 연돌효과에 의한 공기 및 오염물질 이동에 관한 연구 (A study on the contaminant dispersion by stack effect in high-rise residential building)

  • 이준호;이중훈;송두삼
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.97-102
    • /
    • 2010
  • With the building is higher and higher, the stack effect is more and more remarkable. The stack effect accompanies many problems in high-rise building such as draft, troublesome in door opening, uncomfortable noise, contaminants dispersion, etc. In this study, the air movement and accompanied contaminants dispersion by stack effect in high-rise building, and diluting the contaminants concentration were analyzed. The analysis was performed for high-rise residential building in Seoul, Korea and the network simulation method was used. The results show that the indoor contaminants concentration and air movement caused by stack effect have interdependent relationship.

고온형 고분자 전해질 연료전지 스택 내부의 냉각판 수가 스택에 미치는 열 영향성의 수치적 연구 (Analysis of Thermal Effect by Coolant Plate Number in High-Temperature Polymer Electrolyte Membrane Fuel Cell Stack)

  • 최병욱;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.127-135
    • /
    • 2015
  • High-Temperautre Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) with phosphoric acid-doped polybenzimidazole (PBI) membrane has high power density because of high operating temperature from 100 to $200^{\circ}C$. In fuel cell stack, heat is generated by electrochemical reaction and high operating temperature makes a lot of heat. This heat is caouse of durability and performance decrease about stack. For these reasons, heat management is important in HT-PEMFC. So, we developed HT-PEMFC model and study heat flow in HT-PEMFC stack. In this study, we placed coolant plate number per cell number ratio as variable and analysed heat flow distribution in stack.

고분자 전해질 연료전지의 개방회로 전위차 측정 및 분석 (Measurement and Analysis of Open Circuit Potential in PEFC)

  • 김홍건;김유신;김홍열
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.134-138
    • /
    • 2004
  • The discrepancies between theoretical values and measured data of PEFC(Proton Exchange Fuel Cell) is carried out for the machine tool power generation. Rudimental approach of theoretical fuel cell open circuit potential using Gibbs free energy is employed for the examination of PEFC module. The stack temperature, stack voltage and stack current are measured during the operation of PEFC module. It is found that stack voltage and current values show the pronounced discrepancy with the results calculated by Gibbs free energy approach. It is analysed that the discrepancy is due to activation polarization, concentration overvoltage and ohmic overvoltage.

  • PDF

고층건물에서의 연돌효과 시뮬레이션 (Simulation of the Stack Effect in High-Rise Builbings)

  • 양인호;여명석;조재훈;김광우
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.456-467
    • /
    • 2002
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impact of the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal airflow resistance, so the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

실측과 시뮬레이션을 통한 초고층 주거건물에서의 연돌효과 문제의 해결 (Solving the Problems Caused by Stack Effect in a High-rise Residential Building through Field Measurement and Simulation; Case Study)

  • 구성한;조재훈;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제16권4호
    • /
    • pp.73-80
    • /
    • 2005
  • A high-rise residential building experienced stack effect problems during the winter such as difficulties in opening residential entrance doors and whistling noise from elevator doors generated by airflow. Field measurements were carried out on the building and the problems were verified by the analysis of the measurement results from three points of view: the total stack pressure difference, pressure distribution on each floor, and the location of the neutral pressure level. Based on the analysis of the three key parameters, possible solutions were proposed, such as zoning vertical shafts, lessening the airflow from the entrance doors on basement floors and lobby floor by installing vestibules, improving the airtightness of exterior walls, and installing separation doors where the problems occur. Simulations of proposed solutions were conducted and the effects of reducing the pressure difference were evaluated. Stack effect problems in a high-rise residential building were verified through field measurements and could be mitigated by the solutions which were drawn from the analysis of the field measurements and the simulation results.

건축물 계단에서의 연돌효과 저감방안에 대한 현장실험 연구 (Study on Field Experiment of Stack Effect Reduction in Stairwell of Building)

  • 김정엽;김지석;이수각
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.484-490
    • /
    • 2015
  • The winter stack effect that occurs in vertical construction passages such as the stairwell or elevator shaft of a high-rise building negatively affects living environments, energy usage, and personal safety; therefore, a mitigation of the stack effect is required to improve building conditions. Recently, circulation-type facilities that comprise the usage of air blowers and vertical ducts were proposed as part of a mechanical approach to quantitatively control the stack effect. In this study, these circulation-type facilities were installed in a building stairwell and the performance of the device was evaluated during its operation. A numerical-analysis result was obtained under the test conditions using a network-model-based, numerical-analysis method, and the result was then used for a comparison with the test result.