• Title/Summary/Keyword: stable current

Search Result 1,878, Processing Time 0.032 seconds

Operating characteristics of linear type magnetic flux pump (리니어타잎 초전도 전원장치의 동작특성)

  • Chung, Yoon-Do;Bae, Duck-Kweon;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.665-666
    • /
    • 2008
  • Inserted HTS (high temperature superconducting) coil is promisingly expected as a solution for achievement of higher fields such as GHz scale NMR magnet. However, HTS magnet causes persistent current decay in the persistent current mode and this decay should be compensated in order to keep stable magnetic field. As a solution for the decay in the HTS magnets, we proposed a new type superconducting power supply, i.e., linear type magnetic flux pump (LTMFP). The LTMFP mainly consists of DC bias coil, 3-phase AC coil and superconducting Nb foil. The compensating current in closed superconductive circuit can be easily controlled by the intensity of 3-phase AC current and its frequency. In this study, it has been investigated that the flux pump can effectively charge the current for various frequencies according to the different load magnets.

  • PDF

Dynamic Characteristics Control of a Step-down Chopper Using Load current Feed-forward Compensator (부하전류 전향보상기를 이용한 강압쵸퍼의 동특성 제어)

  • Chung, Chun-Byung;Chun, Ji-Yong;Jeon, Kee-Young;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.66-69
    • /
    • 2008
  • In this paper, The author present a load current feed-forward compensator by method that improve voltage controller of Step-down Chopper to get stable output voltage to sudden change of load current. To confirm the characteristicsof a presented load current feed -forward compensator compared each transfer function of whole system that load current feed-forward compensator is added with transfer function of whole system that existent voltage controller is included using Mason gains formula in Root locus and Bode diagram. As a result the pole of system is improved, extreme point of the wave and system improves, and size of peak value and phase margin of break frequency in resonance frequency confirmed that is good. Therefore, presented control technique could confirm that reduce influence by perturbation and improves stationary state and dynamic characteristics in output of Step-down Chopper.

  • PDF

Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions (전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘)

  • Song Seung-Ho;Kim Jeong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

Grid Voltage-sensorless Current Control of LCL-filtered Grid-connected Inverter based on Gradient Steepest Descent Observer

  • Tran, Thuy Vi;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.380-381
    • /
    • 2019
  • This paper presents a grid voltage-sensorless current control design for an LCL-filtered grid-connected inverter with the purpose of enhancing the reliability and reducing the total cost of system. A disturbance observer based on the gradient steepest descent method is adopted to estimate the grid voltages with high accuracy and light computational burden even under distorted grid conditions. The grid fundamental components are effectively extracted from the estimated gird voltages by means of a least-squares algorithm to facilitate the synchronization process without using the conventional phase-locked loop. Finally, the estimated states of inverter system obtained by a discrete current-type full state observer are utilized in the state feedback current controller to realize a stable voltage-sensorless current control scheme. The effectiveness of the proposed scheme is validated through the simulation results.

  • PDF

Sensorless Vector Control of Induction Motor Using the Flux Estimator (자속추정기를 이용한 유도전동기 센서리스 벡터제어)

  • 김경서;조병국
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.87-92
    • /
    • 2003
  • This paper presents a flux estimator for the sensorless vector control of induction motors. The proposed method utilize the combination of the voltage model based on stator equivalent model and the current model based on rotor equivalent model, which enables stable estimation of rotor flux in high speed region and in low speed region. The dynamic performance of proposed method is verified through the experiment. The experimental results show that motors ran easily start even under 150[%] load condition and operate continuously below 0.5[Hz].

Electrical Switching Mechanism of the Sintering Oxides (산화물 소결체에서 전기적 Switching 기구)

  • 조동산;김화택
    • Journal of the Korean Ceramic Society
    • /
    • v.15 no.3
    • /
    • pp.135-139
    • /
    • 1978
  • Sintering oxide which was prepared by sintering at $1200^{\circ}C$ the mixture of ${\gamma}$-$Fe_2O_3$ and $Sb_2O_3$ in 2 : 1 mol ratio, showed 1st electrical switching and stable 2nd switching when D.C. voltage was applied. This electrical switching mechanism was known to be thermal mechanism from dependence of environmental temperature of threshold Voltage(Vm), Current(Im) and the conductivity of the current filament of the sintering oxide.

  • PDF

Displacement Sensorless Active Magnetic Bearing Control by Current Measurement (전류신호를 이용한 능동 자기 베어링계의 제어)

  • 권계시;정호섭;이종원
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.49-57
    • /
    • 1995
  • An electronic circuit device is developed such that the displacement between an electromagnet and a moving target can be estimated from the coil current measurement, and then applied to an active magnetic bearing system. In order to levitate the shaft without using displacement sensor the stable control gains are obtained from the linearized model which includes the gap estimation circuit. Experimental results show that the shaft, by the estimated gap feedback, can be levitated within $\pm$6 ${\mu}m$ positioning error.

  • PDF

Characteristics of the closed microhollow cathode discharge for DC Plasma Display Panels

  • Park, Hae-Il;Noh, Joo-Hyon;Ryu, Byung-Gil;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.105-106
    • /
    • 2000
  • The positive slope of the current-voltage characteristic at pressure up to 850 torr was obtained using the closed microhollow cathode without the individual and/or distributed ballast. This indicates that the stable parallel operation of the discharge was also achieved using the closed microhollow cathode. The parallel operation makes it possible to manufacture de plasma displays with high pressure, small discharge current, and long lifetime.

  • PDF

Controlling Characteristics of a Self-Excited D.C Moter Driven by a Thyristor Chopper (직류 Chopper방식에 의한 직류자격자식 전동기 특성에 대하여)

  • 천희영
    • 전기의세계
    • /
    • v.19 no.3
    • /
    • pp.10-17
    • /
    • 1970
  • The main focus of this paper is the analysis on the controlling characteristics of self-excited D.C. motor driven by thyristor chopper. The controlling characteristics of short shunt compound motor driven by poly phase multiple thyristor chopper is better than that of driven by single phase thyristor chopper. And we got the following conclusions. A. Motor current capacity could be increased by the multiplicity n increase. B. Speed-torque characteristics is linear and adquate for constant Horsepower motor. C. Maximum current Riple ratio is proportional to almost inverse m$^{2}$. Also here shows the stable conditions and semiconducterlize datas for controlling the self-excited D.C. motor driven by thyristor chopper.

  • PDF

Speed Control of DC Series Wound Motor Using a Genetic A1gorithm with Self-Tuning Method (유전알고리즘의 자기동조 방법에 의한 직류 직권모터 모터 속도제어)

  • Bae, Jong-Il;Je, Chang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2763-2765
    • /
    • 2003
  • Generally, we made use of PID control for torque control, speed control and stability, Hence, dynamic characteristic of DC motor has been studied for stable drive and accurate speed control by many engineers. But, in this paper, we applied genetic algorithm to current control for robust control and stability In conclusion, we prove that current control of genetic algorithm can be high efficiency.

  • PDF