• Title/Summary/Keyword: stability function

Search Result 2,703, Processing Time 0.027 seconds

A Study on Shape Optimization of Plane Truss Structures (평면(平面) 트러스 구조물(構造物)의 형상최적화(形狀最適化)에 관한 구연(究研))

  • Lee, Gyu won;Byun, Keun Joo;Hwang, Hak Joo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.49-59
    • /
    • 1985
  • Formulation of the geometric optimization for truss structures based on the elasticity theory turn out to be the nonlinear programming problem which has to deal with the Cross sectional area of the member and the coordinates of its nodes simultaneously. A few techniques have been proposed and adopted for the analysis of this nonlinear programming problem for the time being. These techniques, however, bear some limitations on truss shapes loading conditions and design criteria for the practical application to real structures. A generalized algorithm for the geometric optimization of the truss structures which can eliminate the above mentioned limitations, is developed in this study. The algorithm developed utilizes the two-phases technique. In the first phase, the cross sectional area of the truss member is optimized by transforming the nonlinear problem into SUMT, and solving SUMT utilizing the modified Newton-Raphson method. In the second phase, the geometric shape is optimized utilizing the unidirctional search technique of the Rosenbrock method which make it possible to minimize only the objective function. The algorithm developed in this study is numerically tested for several truss structures with various shapes, loading conditions and design criteria, and compared with the results of the other algorithms to examme its applicability and stability. The numerical comparisons show that the two-phases algorithm developed in this study is safely applicable to any design criteria, and the convergency rate is very fast and stable compared with other iteration methods for the geometric optimization of truss structures.

  • PDF

A Study on the Ecological Indices for the Assessment of the Function and Maturity of Artificial Reefs (인공어초의 기능도와 성숙도 평가를 위한 생태학적 지수에 대한 연구)

  • Yoo, Jae-Won;Hong, Hyun-Pyo;Hwang, Jae-Youn;Lee, Min-Soo;Lee, Yong-Woo;Lee, Chae-Sung;Hwang, Sun-Do
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.1
    • /
    • pp.8-34
    • /
    • 2014
  • We reviewed foreign evaluation systems based on the macrobenthic and macroalgal communities and developed a system, composed of a set of ecological indices able to evaluate the functionality (FI, Functional Index; estimation of stability and productivity) and maturity (MI, Maturity Index; comparisons with biological parameters of natural reefs) of artificial reefs by comparing the status in the adjacent natural reefs in Korean coastal waters. The evaluation system was applied to natural and artificial reefs/reef-planned areas (natural reefs), established in the 5 marine ranching areas (Bangnyeong-Daechung, Yeonpyung, Taean, Seocheon and Buan) in the west coast of Korea. The FI ranged between 31.6 (Bangnyeong-Daechung) and 72.5% (Buan) and MI did between 53.1 (Seocheon) and 76.9% (Taean) in average. The evaluation of artificial reefs by the two indices, showed the most appropriate status in Taean. The FI between the adjacent artificial and natural reefs were in significant linear relationship ($r^2=0.83$, p=0.01). This indicated the local status of biological community may be critical in determining the functionality of the artificial reefs. We have suggested an integrative but preliminary evaluation system of artificial reefs in this study. The output from the evaluation system may be utilized as a tool for environment/resource managers or policy makers, responsible for effective use of funds and decision making. Given the importance, we need to use the options to enhance and improve the accuracy as follows: (1) continuous validation of the evaluation system and rescaling the criteria of indicators, (2) vigorous utilization of observation and experience through the application and data accumulation and (3) development and testing of brand-new indicators.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

Effects of Arginine Vasopressin(AVP) Infusion on the Patients with Catecholamine-dependent Septic Shock (카테콜아민계 승압제를 투여중인 패혈성 쇼크 환자에서 아르기닌 바소프레신(AVP)의 효과)

  • Sheen, Seung Soo;Lim, Seung Guan;Jo, Sook Kyoung;Song, Kyoung Eun;Lee, Hyoung No;Oh, Yoon Jung;Park, Kwang Joo;Hwang, Sung Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.506-515
    • /
    • 2003
  • Background : A decreased level of serum arginine vasopressin(AVP) and an increased sensitivity to an exogenous AVP is expected in patients with septic shock who often require a high infusion rate of catecholamines. The goal of the study was to determine whether an exogenous AVP infusion to the patients with septic shock would achieve a significant decrement in infusion rate of catecholamine vasopressors while maintaining hemodynamic stability and adequate urine output. Method : Eight patients with septic shock who require a high infusion rate of norepinephrine had received a trial of 4-hour AVP infusion with simultaneous titration of norepinephrine. Hemodynamic parameters and urine output were monitored during the AVP infusion and the monitoring continued up to 4 hours after the AVP infusion had stopped. Results : Mean arterial pressure showed no significant changes during the study period(p=0.197). Norepinephrine infusion rate significantly decreased with concurrent AVP administration(p=0.001). However, beneficial effects had disappeared after the AVP infusion was stopped. In addition, hourly urine output showed no significant changes throughout the trials(p=0.093). Conclusion : Concurrent AVP infusion achieved the catecholamine vasopressor sparing effect in the septic shock patients, but there was no evidence of the improvement of renal function. Further study may be indicated to determine whether AVP infusion would provide an organ-protective effect to the septic shock patients.

Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern (7마일 등명기를 결합한 경량화 등부표의 운동 해석)

  • Son, Bo-Hun;Ko, Seok-Won;Yang, Jae-Hyoung;Jeong, Se-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.628-636
    • /
    • 2018
  • Because large buoys are mainly made of steel, they are heavy and vulnerable to corrosion by sea water. This makes buoy installation and maintenance difficult. Moreover, vessel collision accidents with buoys and damage to vessels due to the material of buoys (e.g., steel) are reported every year. Recently, light buoys adopting eco-friendly and lightweight materials have come into the spotlight in order to solve the previously-mentioned problems. In Korea, a new lightweight buoy with a 7-Nautical Mile lantern adopting expanded polypropylene (EPP) and aluminum to create a buoyant body and tower structure, respectively, was developed in 2017. When these light buoys are operated in the ocean, the visibility and angle of light from the lantern installed on the light buoys changes, which may cause them to function improperly. Therefore, research on the performance of light buoys is needed since the weight distribution and motion characteristics of these new buoys differ from conventional models. In this study, stability estimation and motion analyses for newly-developed buoys under various environmental conditions considering a mooring line were carried out using ANSYS AQWA. Numerical simulations for the estimation of wind and current loads were performed using commercial CFD software, Siemens STAR-CCM+, to increase the accuracy of motion analysis. By comparing the estimated maximum significant motions of the light buoys, it was found that waves and currents were more influential in the motion of the buoys. And, the estimated motions of the buoys became larger as the sea state became worser, which might be the reason that the peak frequencies of the wave spectra got closer to those of the buoys.

Magnetoresistive of (NiFe/CoFe)/Cu/CoFe Spin-Valvec ((NiFe/CoFe)/Cu/CoFe Spin-Valve 박막의 자기저항 특성)

  • 오미영;이선영;이정미;김미양;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.5
    • /
    • pp.265-273
    • /
    • 1997
  • The MR ratios and the exchange biasing field and interlayer coupling field were investigated in $Ni_{91}Fe_{19}/Co_{90}Fe_{10}/Cu/Co_{90}Fe_{10}/NiO$ spin-valve sandwiches grown on antiferromagnetic NiO films as a function of the NiO thickness, the thickness of Cu and pinning layer $Co_{90}Fe_{10}$. The spin-valve sandwiches were deposited on the Corning glass 7059 by means of the 3-gun dc and 1-gun rf magnetron sputtering at a 5 mtorrpartial Ar pressure and room temperature. The deposition field was 50 Oe. The MR curve was measured by the four-terminal method with applied magnetic soft bilayer [NiFe/CoFe] (90$\AA$) decreased dramatically to less than 10 Oe when the NiFe/CoFe bilayer used an NiFe bilayer thicker that 20$\AA$. So NiFe layer improved the softmagnetic properties in the NiFe/CoFe bilayer. The GMR ratio and the magnetic field sensitivity of the spin-valve film $Ni_{91}Fe_{19}(40{\AA})/Co_{90}Fe_{10}(50{\AA}) /Cu(30{\AA})/Co_{90}Fe_{10}(35{\AA})/NiO(800{\AA})$ was 6.3% and about 0.5 (%/Oe), respectively. The MR ratio had 5.3% below an annealing temperature of 20$0^{\circ}C$ which slowly decreased to 3% above 30$0^{\circ}C$. The large blocking temperature of the spin-valve film was taken (as being) due to the good stability of the NiO films. Thus, the spin-valve films with a free NiFe/CoFe layer clearly had a high large GMR output and showed a effective magnetic field sensitivity for a suitable spin-valve head material.

  • PDF

Latarjet Operation for Anterior Shoulder Instability with Glenoid Bone Defect (관절와 골 결손을 동반한 견관절 전방 불안정증에 대한 Latarjet 술식)

  • Cho, Seung-Hyun;Cho, Nam-Su;Yi, Jin-Woong;Choi, Il-Hun;Kwack, Yoon-Ho;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • Purpose: We wanted to evaluate the clinical results of the Latarjet procedure for treating anterior shoulder instability combined with a glenoid bone defect. Materials and Methods: Between Oct. 2006 and May. 2007, fourteen patients underwent a Latarjet operation to treat their anterior shoulder instability combined with a glenoid bone defect. The mean follow-up period was 15 months (range: 12 to 19 months), and the average age at the time of surgery was 29.9-years-old (range: 19 to 44 years). There were 13 males and 1 female. Eight patients exhibited involvement of the right shoulder. The dominant arm was involved in 8 patients. Six patients had undergone a previous arthroscopic Bankart repair before their Latarjet operation and 2 patients had a history of seizure. Results: The average Rowe score improved from 51.8 to 80.2 with 9 excellent, 4 good, and 1 fair results. The average Korean shoulder score for instability improved from 61.6 to 82.1 postoperatively. The active forward flexion and external rotation at the side of the involved shoulder was an average of $8^{\circ}$ and $16^{\circ}$ less than that of the uninvolved shoulder. The muscle strength of the involved shoulder measured 78.7% in forward flexion and 82.5% in external rotation, as compared with that of the uninvolved shoulder. There was 1 case of dislocation, 1 transient subluxation, 2 fibrotic unions, 1 resorption of the transferred coracoid process, 1 intraoperative broken bone, 1 transient musculocutaneous nerve injury and 1 case of stiffness. Conclusion: The Latarjet procedure for treating anterior shoulder instability combined with a significant glenoid defect effectively restores function and stability through extending the articular arc at the expense of external rotation. We should be cautious to avoid or detect complications when performing coracoid transfer.

Effect of Intravenous Administration of Tramadol on the Minimum Alveolar Concentration of Isoflurane in Dogs (개에서 트라마돌의 정맥투여가 아이소플루란의 최소폐포농도에 미치는 영향)

  • Seok, Seong-Hoon;Park, Se-Jin;Lee, Seung-Yong;Jin, So-Young;Kim, Young-Ki;Hwang, Jae-Min;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.308-312
    • /
    • 2015
  • This study was aimed to evaluate the effects of tramadol hydrochloride on the minimum alveolar concentration of isoflurane ($MAC_{ISO}$) in dogs. Six healthy, female German shepherd dogs (aged 1-2 years) were used in this study. Anesthesia was induced by mask induction and maintained with isoflurane in oxygen. Mechanical ventilation maintained the end-tidal $CO_2$ partial pressure ($P_{ET}CO_2$) from 35 to 45 mmHg throughout the study. A baseline $MAC_{ISO}$ ($MAC_{ISO}B$) was determined starting 45 minutes after induction of anesthesia by clamping a pedal digit until gross purposeful movement was detected. After $MAC_{ISO}B$ determination, dogs received a tramadol loading dose of 3 mg/kg followed by a continuous rate infusion (CRI) of 2.6 mg/kg/h. The determination of $MAC_{ISO}$ after administration of tramadol ($MAC_{ISO}T$) began 20 min after the start of the CRI. Arterial blood pressure and heart rate were recorded continuously and arterial blood samples for blood gas analysis were collected at the end of the equilibration period. Mean ${\pm}$ SD values for the $MAC_{ISO}B$ and $MAC_{ISO}T$ were $1.33{\pm}0.04%$ and $1.23{\pm}0.04%$, respectively. The $MAC_{ISO}B$ decreased significantly by $7.5{\pm}0.2%$ (P < 0.05) after administration of tramadol. The mean heart rate and arterial blood pressure of six dogs were not changed significantly after tramadol administration. The blood gas levels remained constant during the study. In conclusion, tramadol could significantly reduce $MAC_{ISO}$ without depression of cardiorespiratory function. Thus, the use of tramadol on inhalation anesthesia with isoflurane in dogs can improve the stability of anesthesia and the quality of recovery.

Anterior Cruciate Ligament Reconsruction Using Tibialis Tendon Allograft - A Short-Term Follow-Up Result - (동종 경골건을 이용한 전방 십자 인대 재건술 -단기 추시 결과-)

  • Woo, Jong-Ken;Ko, Sang-Hun;Lew, Sog-u;Park, Moon-Soo;Jung, Kwang-Hwan;Gwak, Chang-Youl;Lee, Chae-Chil;Cho, Sung-Do
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Purpose: To evaluate the clinical stability and function after arthroscopic anterior cruciate ligament(ACL) reconstruction using fresh-frozen tibialis tendon allograft. Materials and Methods: Of the patients who underwent ACL reconstruction using tibialis tendon allograft from July 2002 to June 2003, thirty-one patients could be evaluated and the mean follow-up period was 19 months. Evaluations included were Lysholm knee score, 2000 International knee Documentation Committee (IKDC) subjective knee score, Lachman test, pivot shift test, KT-1000 arthrometer measurement and 2000 IKDC knee examination. Results: The mean Lysholm score was 88. Twenty-eight patients (90.3%) were good or exellent for the measured parameters. Twenty-seven patients(87.1%) was over 70 in IKDC subjective knee score. Thirty patients (96.8%) had 1+ firm end or negative Lachman test. 27 patients (87.1%) had a negative pivot shift. Thirty patients (96.8%) had less than 5mm difference of maximal manual difference by KT-1000 arthrometer. Twenty -nine patients (93.5%) were nearly normal or normal grade by 2000 IKDC knee examination. Complications were 1 case of failure and 1 case of infection. Conclusion: ACL reconstruction with the double-stranded fresh-frozen tibialis tendon allograft resulted in a reliable and predictable outcome after short-term follow-up.

  • PDF

Factor Analysis Affecting on Changes in Handysize Freight Index and Spot Trip Charterage (핸디사이즈 운임지수 및 스팟용선료 변화에 영향을 미치는 요인 분석)

  • Lee, Choong-Ho;Kim, Tae-Woo;Park, Keun-Sik
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.2
    • /
    • pp.73-89
    • /
    • 2021
  • The handysize bulk carriers are capable of transporting a variety of cargo that cannot be transported by mid-large size ship, and the spot chartering market is active, and it is a market that is independent of mid-large size market, and is more risky due to market conditions and charterage variability. In this study, Granger causality test, the Impulse Response Function(IRF) and Forecast Error Variance Decomposition(FEVD) were performed using monthly time series data. As a result of Granger causality test, coal price for coke making, Japan steel plate commodity price, hot rolled steel sheet price, fleet volume and bunker price have causality to Baltic Handysize Index(BHSI) and charterage. After confirming the appropriate lag and stability of the Vector Autoregressive model(VAR), IRF and FEVD were analyzed. As a result of IRF, the three variables of coal price for coke making, hot rolled steel sheet price and bunker price were found to have significant at both upper and lower limit of the confidence interval. Among them, the impulse of hot rolled steel sheet price was found to have the most significant effect. As a result of FEVD, the explanatory power that affects BHSI and charterage is the same in the order of hot rolled steel sheet price, coal price for coke making, bunker price, Japan steel plate price, and fleet volume. It was found that it gradually increased, affecting BHSI by 30% and charterage by 26%. In order to differentiate from previous studies and to find out the effect of short term lag, analysis was performed using monthly price data of major cargoes for Handysize bulk carriers, and meaningful results were derived that can predict monthly market conditions. This study can be helpful in predicting the short term market conditions for shipping companies that operate Handysize bulk carriers and concerned parties in the handysize chartering market.