Design and Construction of an HTS DC SQUID Electronic Gradiometer NDE system

  • Kim, J.Y.;Han, S.G.;Kang, J.H.;Lee, E.H.;Song, I.H.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.115-119
    • /
    • 2000
  • We designed and constructed a non-destructive evaluation system using an HTS DC SQUID electronic gradiometer. Our DC SQUID electronic gradiometer is composed of two DC SQUID magnetometers. The system included a non-magnetic stainless steel cryostat and a set of coaxial exciting coils, which were used to induce an eddy current in the test piece. We also have calculated the eddy current density produced by an exciting coil in any direction of the testing object. We could compute the eddy current density distribution in 3D. The SQUIDs were computer controlled and the output data from the electronic gradiometer was obtained by using a Labview software.

  • PDF

Low Frequency Noise Properties of YBCO SQUID Gradiometers (YBCO SQUID gradiometers의 저주파 잡음 특성 연구)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.68-73
    • /
    • 2002
  • We have fabricated YBCO SQUID 1st order gradiometers on $30^{\circ}$STO bicrystal substrate. The pickup coil size was 3.8mm$\times$3.8mm and baseline was 5mm. Three types of SQUID gradiometer were designed and tested for unshielded operation; solid pickup coil, pickup coil consisting of 4 parallel $ 50\mu\textrm{m}$-wide loops, and solid pickup coil with flux dam. We have investigated external magnetic field dependence of the SQUID gradiometers on the magnetic field noiseproperties. Significant increase of low frequency noise with the application of static field has been observed in the case of parallel and flux dam type pickup coil above threshold field of $1.3 \mu$T. Magnetic field noise at 1 Hz measured in the magnetically shielding room was 30, 165, 480 fTcm/sup -1/Hz/sup -1/2/ for solid type and slot type and parallel loops type, respectively.

  • PDF

Numerical study of topological SQUIDs

  • Soohong, Choi;Yeongmin, Jang;Sara, Arif;Yong-Joo, Doh
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.11-15
    • /
    • 2022
  • We conducted numerical calculations to obtain the critical current as a function of the magnetic flux through the topologically trivial and non-trivial superconducting quantum interference devices (SQUIDs), with varying the capacitive and inductive couplings of Josephson junctions (JJs). Our calculation results indicate that a nontrivial SQUID is almost indistinguishable from trivial SQUID, considering the effective capacitance coupling. When the SQUID contains 2π- and 4π-periodic supercurrents, the periodicity of the current-flux relation can be distinguished from the purely trivial or nontrivial SQUID cases, and its difference is sensitive to the relative ratio between the topologically trivial and nontrivial supercurrents. We believe that our calculation results would provide a practical guide to quantitatively measure the portion of the topologically nontrivial supercurrents in experiments.

Cholestrol Content and Formation of Oxidized Cholesterols in Processed Squids

  • Hong, Jeung-Hoon;Ryu, Hong-soo;Kim, Heung-Bae
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.2
    • /
    • pp.196-202
    • /
    • 1996
  • The effect of cooking(boiling, steaming and baking0and drying on the cholesterol content and formation of oxidized cholesterols in quid(Japanese flying squid, Todarodes pacificus) was studied. Cholesterol content of live squid meat varied with the portion sampled, and results from spectrophotometric assay ranged from 263.2mg/1..g(mantle) to 315.8mg/100g(tentacle). The cholesterol levels analyzed by gas chromatography(GC) for squid samples were lower by 7% of total cholesterol for live squid meat and 24% for processed meat than those results by spectrophotometric assay. Cooking resulted in the decrease of the initial total cholesterol content of raw meat from 10%(boiling for 5min.) to 25%(steaming for 5min.) The amounts of cholesterol remaining after baking were 68% for microwave oven samples and 64% for convection oven samples. Drying of raw tissue caused the greater reduction in cholesterol content than cooking but showed no significant difference in samples stored for 6 weeks at 4$^{\circ}C$ and 2$0^{\circ}C$. Raw squid meats contained essentially no oxidized cholesterols, while the 22-hydroxychoesterol was detected in frozen meats. The additional oxidized cholesterols as cholestane-triol was indentified with 22-hydroxycholesterols in cooked samples. Sun dried meat stored at 4一 and 2$0^{\circ}C$ for 6 weeks had the three kinds of oxidized cholesterols such as 22-hydroxycholesterol, cholesta-3,5-dien-7-one and cholestane-triol.

  • PDF

High-$T_c$ SQUID Application for Roll to Roll Metallic Contaminant Detector

  • Tanaka, S.;Kitamura, Y.;Uchida, Y.;Hatsukade, Y.;Ohtani, T.;Suzuki, S.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.82-86
    • /
    • 2012
  • A sensitive eight-channel high-Tc Superconducting Interference Device (SQUID) detection system for magnetic contaminant in a lithium ion battery anode was developed. Finding ultra-small metallic foreign matter is an important issue for a manufacturer because metallic contaminants carry the risk of an internal short. When contamination occurs, the manufacturer of the product suffers a great loss from recalling the tainted product. Metallic particles with outer dimensions smaller than 100 microns cannot be detected using a conventional X-ray imaging system. Therefore, a highly sensitive detection system for small foreign matter is required. We have already developed a detection system based on a single-channel SQUID gradiometer and horizontal magnetization. For practical use, the detection width of the system should be increased to at least 65 mm by employing multiple sensors. In this paper, we present an 8-ch high-Tc SQUID roll-to-roll system for inspecting a lithium-ion battery anode with a width of 65 mm. A special microscopic type of a cryostat was developed upon which eight SQUID gradiometers were mounted. As a result, small iron particles of 35 microns on a real lithium-ion battery anode with a width of 70 mm were successfully detected. This system is practical for the detection of contaminants in a lithium ion battery anode sheet.

A semispherical SQUID magnetometer system using high sensitivity double relaxation oscillation SQUIDs for magnetoencephalographic measurements

  • Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kim, Kwoong;Park, Yong-Ki
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2003
  • We designed and constructed a multichannel superconducting quantum interference device (SQUID) magnetometer system to measure magnetic fields from the human brain. We used a new type of SQUID, the double relaxation oscillation SQUID (DROS). With high flux-to-voltage transfers of the DROS, about 10 times larger than the dc SQUIDs, simple flux-locked loop circuits could be used for SQUID operation. Also the large modulation voltage of the DROS, typically being 100 $mutextrm{V}$, enabled stable flux-locked loop operation against the thermal offset voltage drift of the preamplifier. The magnetometers were fabricated using the Nb/AlOx/Nb junction technology. The SQUID system consists of 37 signal magnetometers, distributed on a semispherical surface, and 11 reference channels were installed to pickup background noises. External feedback was used to eliminate the magnetic coupling with the adjacent channels. The liquid helium dewar has a capacity of 29 L and boil-off rate of about 4 L/d with the total 48 channel insert. The magnetometer system has an average noise level of 3 fT/√Hz at 100 Hz, inside a shielded loon, and was applied to measure auditory-evoked fields.

Manufacture of Squid-Jeotgal by the Improved Process (개선된 제조기법에 의한 오징어젓갈 제조)

  • YOON Ji-Hye;LEE Won-Dong;KANG Ji-Hee;LEE Ji-Sun;LEE Myung-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.4
    • /
    • pp.333-339
    • /
    • 2003
  • New manufacturing process was applied to manufacture the low salted Squid-Jeotgal to improve the quality variation salty taste and shelf-life. It's optimum salting and sugaring process was made by the addition of $17\%$ NaCl for 3 hr and $15\%$ corn syrup for 4 hr with 10 rpm agitation. Quality variations of Squid-Jeotgal produced by the improved and the conventional process were packed by jar, polyethylene lerephthalatefpolyethyleneilinear low density polyethylene (PET) and low density polyethylene (PE). And then quality variations of them were investigated at storage temperature of 10, 20, and $30^{\circ}C.$ Decreasing rate of pH, increasing rates of VBN and viable cell counts of Squid-Jeotgal produced by the improved process were slower than those of the conventional process at all storage temperature. Sensory evaluation indicated that the production of Squid-Jeotgal by the improved process extended the shelf-life about 10-20 days.

Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer (단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

Fractionation of Endoprotease from Viscera of the Argentina Shortfin Squid Illex argentinus (원양산 오징어(Illex argentinus) 내장으로부터 Endoprotease의 분획)

  • Kim, Hye-Suk;Kim, Jin-Soo;Heu, Min-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.3
    • /
    • pp.176-181
    • /
    • 2008
  • To evaluate the effective use of endoprotease from squid viscera as a food processing aid, various methods of fractionating endoprotease from viscera of the Argentina shortfin squid (Illex argentinus) were evaluated. The endoprotease-positive fractions of each fractionation were fraction II (30-40%, w/w) with cold acetone, fraction IV (50-60% saturation) with ammonium sulfate, fraction UF with anion exchange chromatography, and fraction II (15-24 kDa) with gel filtration. The specific activities (approximately 25 U/mg) of the fractions using ammonium sulfate and gel filtration were higher than the others. Total azocaseinolytic activity and recovery of the positive fraction using gel filtration were 806.95U and 37.82%, respectively, and were the highest among the positive fractions. Based on the results, gel filtration was the most efficient method for fractionating endoprotease from the viscera of Illex argentinus.

Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System (저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작)

  • Kim I. S;Yu K. K;Park Y. K
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF