• Title/Summary/Keyword: square wave voltage

Search Result 126, Processing Time 0.035 seconds

The output characteristics of the input waveform to the PZT bimorph vibrator (입력파형에 따른 PZT 바이몰프 진동자의 출력특성)

  • Kim, Yong-Hyuk;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • The aim of this study is to research maximum harvesting energy by the optimal input wave condition. The voltage characteristics of the PZT bimorph were investigated in terms of the sine wave, triangle wave and square wave according to frequency range 0~70Hz. It was found that the square wave compared with a triangular wave or square wave was showed the higher output energy. PZT bimorph was mechanically vibrated by solenoid coil experiments, which revealed two voltage peak mode according to frequency. Maximum voltage at second vibration frequency 28Hz demonstrated that the generated DC voltage was proportional to the tip displacement of the bimorph and the phase difference between the input frequency and bimorph vibration frequency was 90 degree. It was expected that optimized design to harvest a much higher energy level from lower frequency vibrations.

IPMSM Sensorless Control Using Square-Wave-Type Voltage Injection Method with a Simplified Signal Processing (구형파 신호 주입을 이용한 IPMSM 센서리스 제어에서 개선된 신호처리 기법)

  • Park, Nae-Chun;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.225-231
    • /
    • 2013
  • This paper presents an improved signal processing technique in the square-wave-type voltage injection method for IPMSM sensorless drives. Since the sensorless method based on the square-wave voltage injection does not use low-pass filters to get an error signal for estimating rotor position and allows the frequency of the injected voltage signal to be high, the sensorless drive system may achieve an enhanced control bandwidth and reduced acoustic noise. However, this sensorless method still requires low-pass and band-pass filters to extract the fundamental component current and the injected frequency component current from the motor current, respectively. In this paper, these filters are replaced by simple arithmetic operations so that the time delay for estimating the rotor position can be effectively reduced to only one current sampling. Hence, the proposed technique can simplify its whole signal process for the IPMSM sensorless control using the square-wave-type voltage injection. The proposed technique is verified by the experiment on the 800W IPMSM drive system.

A converting method for square wave to average value in real time (실시간 구형파-평균치 변환 방법)

  • Lee, J.M.;Kim, C.K.;Kim, S.J.;Cheon, J.M.;Park, M.K.;Kwon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.585-587
    • /
    • 2006
  • Generally, LPF(low pass filter) circuits are used for converting square wave to average value, but these are not used necessary for average value of square wave in real time because of time constant of LPF. This paper deals with acquiring method for average value of square wave in real tine in case of frequency of output voltage is fixed, waveform of output voltage is square wave and duty of output voltage is varied like as 1 quadrant or 4 quadrant chopper.

  • PDF

Sensorless Control of IPMSM with a Simplified High-Frequency Square Wave Injection Method

  • Alaei, Ahmadreza;Lee, Dong-Hee;Ahn, Jin-Woo;Saghaeian Nejad, Sayed Morteza
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1515-1527
    • /
    • 2018
  • This paper presents a sensorless speed control of IPMSM (Interior Permanent Magnet Synchronous Motor) using the high-frequency (HF) square wave injection method. In the proposed HF pulsating square wave injection method, injection voltage is applied into the estimated d-axis of rotor and high-frequency induced q-axis current is considered to estimate the rotor position. Conventional square wave injection methods may need complex demodulation process to find rotor position, while in the proposed method, an easy demodulation process based on the rising-falling edge of the injected voltage and carrier induced q-axis current is implemented, which needs less processing time and improves control bandwidth. Unlike some saliency-based sensorless methods, the proposed method uses maximum torque per ampere (MTPA) strategy, instead of zero d-axis command current strategy, to improve control performance. Furthermore, this paper directly uses resultant d-axis current to detect the magnet polarity and eliminates the need to add an extra pulse injection for magnet polarity detection. As experimental results show, the proposed method can quickly find initial rotor position and MTPA strategy helps to improve the control performance. The effectiveness of the proposed method and all theoretical concepts are verified by mathematical equations, simulation, and experimental tests.

A Study on Characteristics of a Volatage-Applied Electrostatic Reducer (전압인가식 제전기의 특성에 관한 연구)

  • 이동훈;정용철
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.77-83
    • /
    • 1995
  • An electrostatic reducer of a multi-pole high DC voltage applied type and a high frequency square wave voltage applied type have been studied to eliminate effectively and safely electrostatic charge on a dummy charged material. As a fundamental experiments, measurement were made on the decay time as a function of distance between electrostatic reducer and charged body, skewed angle of electrostatic reducer installed and wind speed of generated ions(+ or -) by electrostatic reducer with high DC voltage and high frequency square wave voltage. Based oil the results above, a appropriate installation and method were produced as a trial for factory.

  • PDF

Comparative Study on Sinusoidal and Square Wave Driving Methods of EEFL (External Electrode Fluorescent Lamp) for LCD TV Backlight

  • Lee, Yeon-Jae;Oh, Won-Sik;Lee, Sung-Sae;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.325-328
    • /
    • 2005
  • EEFLs are mostly driven by sinusoidal wave driving method although EEFLs (External Electrode Fluorescent Lamps) are driven by both sinusoidal wave and square wave. The sinusoidal driving method reduces the cost and allows more power efficiency since this driving method can reduce the voltage stress of EEFL inverter switches and achieve the soft switching of the switches. And a transformer should be used in the inverter since the high voltage should be applied to the both ends of EEFL to turn on the lamp. However, the power loss mainly occurs at the transformer in the sinusoidal wave driving method. In order to remove the transformer which makes the power loss, a new method is presented. In this paper, the square wave is applied directly to the both ends of EEFL by a proposed two-stage inverter. Moreover, the luminance and power efficiency will be compared between the common sinusoidal wave driving method and square wave driving method.

  • PDF

A Study of the Relationship Analysis of Power Conversion and Changed Capacitance in the Depletion Region of Silicon Solar Cell

  • Kim, Do-Kyeong;Oh, Yeong-Jun;Kim, Sang-Hyun;Hong, Kyeong-Jin;Jung, Haeng-Yeon;Kim, Hoy-Jin;Jeon, Myeong-Seok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.177-181
    • /
    • 2013
  • In this paper, silicon solar cells are analyzed regarding power conversion efficiency by changed capacitance in the depletion region. For the capacitance control in the depletion region of silicon solar cell was applied for 10, 20, 40, 80, 160 and 320 Hz frequency band character and alternating current(AC) voltage with square wave of 0.2~1.4 V. Academically, symmetry formation of positive and negative change of the p-n junction is similar to the physical effect of capacitance. According to the experiment result, because input of square wave with alternating current(AC) voltage could be observed to changed capacitance effect by indirectly method through non-linear power conversion (Voltage-Current) output. In addition, when input alternating current(AC) voltage in the silicon solar cell, changed capacitance of depletion region with the forward bias condition and reverse bias condition gave a direct effect to the charge mobility.

Driving Characteristic for Moving flat core LOA (가동 평판 철심형 LOA의 구동 특성)

  • Jang, S.M.;Lee, D.H.;Kwon, C.;Park, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.745-747
    • /
    • 2001
  • This paper deals with the dynamic characteristics of flat core LOA. The LOA system was represented by the voltage equation of coil and the mechanical equation of motion. Also, driving system was simply composed voltage source inverter and generates square-wave. It is measured that dynamic characteristic vary as square-wave.

  • PDF

Voltage Amplitude Control of Square-Wave VSIs with an R-L Load (R-L부하를 가진 구형파 VSI의 전압크기 제어)

  • Kim Kyung-Won;Hong Soon-Chan;Yoo Jong-Gul;Kim Sang-Kyun;Park Chae-Woon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.479-482
    • /
    • 2001
  • This paper proposes a modified $\alpha$ conduction mode for controlling the output voltage magnitude of three-phase square-wave VSIs with an R-L load. From the viewpoint of both power capacity and switching losses, three-phase square-wave inverters are now used in most high power systems. When the square-wave VSI is driven with $\alpha$ conduction mode to control the magnitude of output voltages, interval over than half period is operated with $180^{\circ}$ conduction mode and the other interval with $120^{\circ}$ conduction mode. In $120^{\circ}$ conduction mode operation, two output terminals are connected to DC supply and the third one remains open. The potential of this open terminal will depend on the load characteristics and is unpredictable except the case of pure resistive loads. To cope this problem, we propose the modified α conduction mode.

  • PDF

Square Wave Voltage Injection Starting Method of SP-PMSM Considering Nonlinearity of Full-bridge Inverter (풀 브릿지 인버터의 비선형성을 고려한 단상 영구자석 동기 전동기의 구형파 전압 주입 기동 기법)

  • Yoo, Sang-Min;Hwang, Seon-Hwan;Lee, Ki-Chang
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.93-98
    • /
    • 2022
  • The purpose of this paper was to propose a method for improving the performance of the open-loop control of single-phase permanent magnet synchronous motor (SP-PMSM), based on a square wave voltage injection. Generally, the SP-PMSM driving systems cmprise a full-bridge inverter and asymmetric air-gap structure of magnetic circuit, because a zero torque occurs on the symmetrical air-gap. As a result, it cannot be started at a specific rotor position. Thus, it is possible to cause the start-up failure at an open-loop control for sensorless operation of SP-PMSM. In this paper, the method with square wave voltage injection considering the nonlinearity of the inverter is presented to resolve the problem. The effectiveness of the proposed algorithm is verified through several experiments.