• Title/Summary/Keyword: spraying performance

Search Result 169, Processing Time 0.025 seconds

Development and Performance Evaluation of a Two-component Thin Spray-on Liner to Guarantee Its Homogeneous Qualities and to Reduce Dust (균질한 품질 확보와 분진 저감을 위한 2성분 박층 뿜칠 라이너의 개발과 성능평가)

  • Chang, Soo-Ho;Choi, Soon-Wook;Lee, Chulho;Kang, Tae-Ho;Hwang, Gwi-Sung;Kim, Jintae;Choi, Myung-Sik
    • Tunnel and Underground Space
    • /
    • v.26 no.5
    • /
    • pp.441-453
    • /
    • 2016
  • This study aimed to develop a two-component TSL suitable for reducing dust and guaranteeing homogeneous qualities during its spraying. Its performance was evaluated by a series of laboratory and field tests. High ductility of two-component TSL prototypes resulted in increasing their elongation at break even though their tensile strengths were slightly lower than those of one-component powder TSLs. One prototype of the two-component TSLs developed in this study was verified to satisfy every criterion specified by EFNARC (2008). Especially, it increased the average compressive strength of mortar specimens by 50% even when it coated them only with the thickness of 3 mm. From a preliminary spraying test, a spraying machine suitable for the developed TSL prototype was derived and modified. After its field application, dust and rebound generated during its spraying works were found to be very minimal. Its spraying rate was recorded to be approximately $60m^2/hr$. In addition, it showed a very rapid hardening characteristic compared with general sprayable waterproofing membranes.

Performance Evaluation and Improvement of Rice Polishers of Small and Medium Size(I)-rice polisher of small size- (중.소형 연미기의 성능평가 및 성능개선에 관한 연구 (I)-소형연미기에 대하여 -)

  • 정종훈;최영수;권홍관
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.06c
    • /
    • pp.141-149
    • /
    • 1997
  • Structural characteristic of a rice polisher of small size was analyzed to improve its performance and to utilize such data in developing a rice polisher of large size. Spraying characteristic of nozzles which were used for rice polishing was evaluated by a machine vision system. Internal pressure of the polishing chamber was also measured according to outlet resistance, water spraying, and roller shaft speed. In addition, the performance of the polisher was analyzed based on whiteness and broken ratio according to operating conditions.

  • PDF

Influence of LPPS Spraying Parameters on Deposition Efficiency of Zirconia Powder

  • Shi, Jian-Min;Hu, Zhong-Yin;Huang, Jing-Qi;Ding, Chuan-Xian
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.160-165
    • /
    • 1997
  • Yttria stabilized zirconia coating is an attractive material for several engineering applications. In order to produce coatings with consistent and reliable performance it is important to understand the influence of spraying parameters on the coating properties and optimize the spraying parameters. In this paper the low pressure plasma spray(LPPS) deposition of as-received zirconia powder has been investigated using simple one-factor-at-a-time approach. The deposition efficiency was chosen to evaluate the melting characteristics of the as-received zirconia powder. The results obtained indicated that the deposition efficiency of zirconia powder is very sensitive to the spraying parameters such as plasma gas flow rate and ranges from 24% to 57% The microstructure and the phase composition of zirconia coating deposited with the different plasma spraying parameters were also examined by SEM and XRD respectively. The relationship between deposition efficiency and the microstructure of zirconia coating was discussed.

  • PDF

An Experimental Study on the Spray Characteristics by Twin-Fluid Atomizer for Wide Band Spray (광폭면 분무를 위한 2유체 노즐의 분무 특성에 관한 연구)

  • Lee, Joong-Soon
    • Journal of ILASS-Korea
    • /
    • v.13 no.4
    • /
    • pp.212-219
    • /
    • 2008
  • To develop the twin-fluid atomizer having the excellent performance of painting, the spray characteristics of how a wide area can be painted efficiently by one time spraying were studied in this paper. Spray phenomena are affected by the many factors determining the spray field such as the spraying pressure of gas, the spraying pressure and viscosity of liquid paints, the opening duration of needle valve, the design dimension of nozzle, and so on. As the results of experiments, these factors affecting on spray characteristics were suggested as followings; 1) The optimum spraying pressure of gas was $0.015{\sim}0.02\;kPa$, and the appropriate spraying pressure of liquid paint was 0.01kPa, In these situations, the setting up pressures must be compensated as much as the losing amount of pressure because a decompression occurred when operating valves. 2) The duration of opening the needle valve must be sustained for $1{\sim}2$ seconds to inject gas after spraying the liquid paint. This operating of the needle valve was necessary to avoid the affect on the changing of liquid column length, and to prevent the droplet deposit at the initial time of spraying. 3) The spray tip penetration was gained form the experimental equation, and the effective spraying angle was $85^{\circ}{\pm}5^{\circ}$ just at he appropriate spraying pressure of gas. The distribution of the area sprayed had the variation in $350{\pm}50\;mm$ because of the spraying pressure of gas, the its distance from the spray tip, and the lift of the needle valve.

  • PDF

Development of a Water-Spraying Type Automatic Glochids Removal System for Cactus (Opuntia humifusa) Stem

  • Jang, Ik Joo;Park, Tusan;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.201-207
    • /
    • 2016
  • Purpose: A water-spraying type automatic glochids removal system for cactus (Opuntia humifusa) stem was developed, and its performance was evaluated. The system was developed to reduce intensive human labor in removing glochids from cactus stem skin without inducing damage prior to further processing into value-added products. Methods: The developed system consists of conveyor and water-spraying systems. The conveyor system delivers cactus stems through water-spraying compartments and finally to a collecting box. In order to remove the glochids, rotating nozzles spray water over all areas (i.e., front and back faces and sides) of the cactus skin under controlled water pressure. Operating conditions such as conveyor speed, water pressure, angle of water-spraying nozzles, distance between conveyor belt and rotating nozzles, and angle of cactus flipping slide were adopted from our previous study and applied on the system design and manufacturing. The performance of glochids removal was evaluated by counting the number of glochids on the cactus stem before and after processing on the system. Results: The developed system performed efficiently and effectively under the pre-studied operating conditions except for the angle of cactus flipping slide. The new system had a glochids removal ratio of 94.1% without damaging the cactus skin. Considering the original number (approximately 30-60) of glochids, the remaining number was low (1-4), and most of them were found at the side edge of the cactus stem. This system can remove glochids from 360 cactus stems in 1 hr regardless of cactus size. Conclusions: The performance of the new system in glochids removal without damaging cactus skin is superior to any other existing device (i.e., brush type, rubber-friction type, and agitation type). The system is expected to be applied in cactus (O. humifusa) processing facilities.

The effect of Nafion$^{(R)}$ ionomer content/distribution and relative humidities on PEMFC performances of MEAs prepared by a CCM spraying method

  • Kim, Kun-Ho;Jeon, Yoo-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • For commercial applications, MEA development must be optimized in order to achieve high performance and low cost. There are many factors that affect the performance of MEA. Especially, the optimization of the method for preparing catalyst layer has great effect on the performance of MEA. Various methods have been used to prepare the catalyst layer of MEA. Among them, spraying method has a merit in that catalysis lay can be prepared with very flexible changes in catalyst layer as well as in the solvent composition of catalyst ink. In addition, in order to reduce the time required for manufacturing catalyst layer, an effort has been made to change the nozzle size and injection pressure of spray system. Further, the operation condition of spray system was changed in various ways in an effort to prepare optimum catalyst layer of MEA. Having optimized the operation condition of spraying system, comprehensive and diverse experiments were carried out concerning various factors that affect the performance of MEA. The present research report describes the results of more sub-categorized and more detailed experiments about the important factors (Nafion$^{(R)}$ ionomer, Relative humidity) which have been shown in previous experiments to exert greater effect on the performance of MEA.

  • PDF

Development of CFD Model for Estimation of Cooling Effect of Fog Cooling System in Greenhouse (온실 포그냉방시스템의 냉방효과 예측을 위한 CFD 모델의 개발)

  • 유인호;김문기;권혁진;김기성
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.93-100
    • /
    • 2002
  • This study was carried out not only to develop CFD model for numerically simulating fog cooling system but also to verify the validity of the developed model by data measured in fag cooling greenhouse. In addition the developed model was applied to investigate the effects of spraying water temperature, spraying water amount, spraying interval and evaporation percentage on the performance of the fog cooling system. According to the simulation results, the temperature differences between the measured and predicted temperatures at each measurement point were $0.1~1.4^{\circ}C$ in case of no shading and $0.2~2.3^{\circ}C$ in close of shading. The humidity differences were 0.3~6.0% and 0.7~10.6%, respectively in the cases of no shading and shading. Because the predicted data showed a good agreement with the measured ones, the developed model is supposed to be able to predict the cooling effect of the fog cooling system. The performance of fog cooling system was greatly influenced by spraying water amount, spraying interval and evaporation percentage, but it was not influenced by spraying water temperature.

The Performance Analysis for Amounts of Sprayed Quantity by Using the Small and Medium-Sized Sprayer (중소형 살포기의 살포량 측정에 따른 성능 분석)

  • Min, Byeong Ro;Hong, Jun Taek;Lee, Dae Weon;Kim, Jea Youl
    • Journal of Animal Environmental Science
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • This study is to promote domestic environmentally appropriately conditions for the range 60~70 m, the development of the small and medium-sized sprayer ability measurement that can be used as a general-purpose paddy fields, orchards, and not consolidated areas. The sprayer designed and manufactured that can spraying effectively distance to within 60~70 m. Distribution of sprayed pesticides were obtained and analyzed by measuring the weight. Performance analysed using the buckets were placed horizontally 12.5 m, 70 m vertical intervals by $5m{\times}2.5m$, so total 68 buckets were placed. Total amounts of sprayed quantity was $2,000{\ell}$ and maximum spray distance was about 70 m. Reasonably sprayed region was 5 m~10 m vertically symmetrical. Showed a lot of spraying water in 5 m~40 m distance, and in 45~60 m tended to spraying water decreased slightly. Maximum spraying distance was 70 m.

Ergonomic and Performance Analyses of a Pull-type Prayer for Floriculture in Greenhouse (시설화훼용 견인형 방제기의 작업자세 및 성능 분석)

  • Lee, Seung-Ki;Kim, Woong
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.426-433
    • /
    • 2010
  • This study was conducted to develop a pull-type sprayer which performs the safe spraying with improved ergonomic postures while pesticide spraying of roses in floricultural facilities. The performance of the ergonomically designed sprayer was analyzed with a comparison of a conventional spray method. The pull-type sprayer, consisting of power pump, hose and nozzle parts was designed to manually pull and spray to upward and horizontal directions. From the analysis of postures with the RULA method, the labor load to arm and wrist using the pull-type sprayer was less than that with conventional power sprayer, so that the intensity of labor reduces. Working capacity with pull-type sprayer was two-fold greater than the conventional power sprayer. After performing pesticide spraying with the pull-type sprayer, the operating cost was reduced to \585,000/yr, which is 79% less than that of cost (\2,197,500/yr) for using conventional power sprayer.

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.