• Title/Summary/Keyword: spiral wave

Search Result 52, Processing Time 0.022 seconds

Homogeneous Dual Composite Right/Left-Handed Metamaterial Using Subwavelength Defected Ground Structure(DGS) (Subwavelength 결함접지구조(defected grounded structure : DGS)를 이용한 Homogeneous Dual Composite Right/Left-Handed 메타물질 구현)

  • Park, Woo-Young;Lim, Sung-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2242-2246
    • /
    • 2009
  • In this paper, a homogeneous dual composite right/left-handed (D-CRLH) transmission line (TL) is proposed by using a defected ground structure (DGS) on the ground plane. In order to satisfy a homogeneity condition of metamaterial, a subwavelength unit cell is designed by way of a spiral DGS and a meander stub. From a dispersion diagram, it is expected that the frequency bands for the left-handed (LH) property is 3.5 - 4.4 GHz. At 3.8 GHz in the LH band, backward propagating phenomenon is observed from full-wave analysis. The experimental results show that the proposed TL has a stop-band in 1.75 - 3.6 GHz.

Asymmetric Mean Metallicity Distribution of the Milky Way's Disk

  • An, Deokkeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.49.1-49.1
    • /
    • 2019
  • I present the mean metallicity distribution of stars in the Milky Way based on photometry from the Sloan Digital Sky Survey. I utilize an empirically calibrated set of stellar isochrones developed in previous work to estimate the metallicities of individual stars to a precision of 0.2 dex for reasonably bright stars across the survey area. I also obtain more precise metallicity estimates using priors from the Gaia parallaxes for relatively nearby stars. Close to the Galactic mid-plane (|Z| < 2 kpc), a mean metallicity map reveals deviations from the mirror symmetry between the northern and southern hemispheres, displaying wave-like oscillations. The observed metallicity asymmetry structure is almost parallel to the Galactic mid-plane, and coincides with the previously known asymmetry in the stellar number density distribution. This result reinforces the previous notion of the plane-parallel vertical waves propagating through the disk, which have been excited by a massive halo substructure such as the Sagittarius dwarf galaxy plunging through the Milky Way's disk. This work provides evidence that the Gaia phase-space spiral may continue out to |Z| ~ 1.5 kpc.

  • PDF

Correlation Analysis of KCNQ1 S140G Mutation Expression and Ventricular Fibrillation: Computer Simulation Study (KCNQ1 S140G 돌연변이 발현과 심실세동과의 상관관계 분석을 위한 컴퓨터 시뮬레이션 연구)

  • Jeong, Daun;Lim, Ki Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.123-128
    • /
    • 2017
  • Background and aims: The KCNQ1 S140G mutation involved in $I_{ks}$ channel is a typical gene mutation affecting atrial fibrillation. However, despite the possibility that the S140G gene mutation may affect not only atrial but also ventricular action potential shape and ventricular responses, there is a lack of research on the relationship between this mutation and ventricular fibrillation. Therefore, in this study, we analyzed the correlation and the influence of the KCNQ1 S140G mutant gene on ventricular fibrillation through computer simulation studies. Method: This study simulated a 3-dimensional ventricular model of the wild type(WT) and the S140G mutant conditions. It was performed by dividing into normal sinus rhythm simulation and reentrant wave propagation simulation. For the sinus rhythm, a ventricular model with Purkinje fiber was used. For the reentrant propagation simulation, a ventricular model was used to confirm the occurrence of spiral wave using S1-S2 protocol. Results: The result showed that 41% shortening of action potential duration(APD) was observed due to augmented $I_{ks}$ current in S140G mutation group. The shortened APD contributed to reduce wavelength 39% in sinus rhythm simulation. The shortened wavelength in cardiac tissue allowed re-entrant circuits to form and increased the probability of sustaining ventricular fibrillation, while ventricular electrical propagation with normal wavelength(20.8 cm in wild type) are unlikely to initiate re-entry. Conclusion: In conclusion, KCNQ1 S140G mutation can reduce the threshold of the re-entrant wave substrate in ventricular cells, increasing the spatial vulnerability of tissue and the sensitivity of the fibrillation. That is, S140G mutation can induce ventricular fibrillation easily. It means that S140G mutant can increase the risk of arrhythmias such as cardiac arrest due to heart failure.

Antidromic Electrically Compound Action Potential in Cochlear Implantees (인공와우 이식자의 역행성 청신경 복합활동전위)

  • Heo, Seung-Deok;Jung, Sung-Wook;Jung, Seung-Hyun
    • Phonetics and Speech Sciences
    • /
    • v.1 no.4
    • /
    • pp.203-207
    • /
    • 2009
  • Electrically evoked compound action potentials (ECAP) have originated from the distal end of the auditory nerve. ECAP are characterized as the difference between the clearly large trough (N) and the following positive peak (P). N-wave occurs around $200-400\;{\mu}s$ after stimulus onset and P-wave at around $400-800\;{\mu}s$. Contrary to expectations, positive peaked ECAP (pp-ECAP) was dominated by a relatively large-amplitude positive following negative peak. pp-ECAP can be recorded from the sites on or near the surgically exposed nerve trunk in animal models and/or in cases of monophasic stimulation. This study will provide the causes of the appearance of pp-ECAP in cases of cochlear implant recipients using imaging studies and medical records and statistically analysis between N-P and P-N on the amplitude input-output function (amp-I/O) for the prediction of the possibilities of clinical tools. Thirteen children participated in the study and received a Cochlear CI-24RE (CA). ECAP was recorded using auto-NRT (Cochlear Ltd., Australia) at four to five weeks post surgery. pp-ECAP was measured from 36 electrodes and typical ECAP from 220 electrodes. There was no abnormality in the imaging study and operation finding in patients with typical ECAP. pp-ECAP was found at the inner ear anormaly and ossification in imaging study and gel-state inner ear fluid was observed in the operation finding. The amplitude of pp-ECAP increased depending on current intensities, but amp-I/O increase more gradually than in the case of typical ECAP (p=0.003). pp-ECAP is antidromic potential which can record from the inner ear anormaly and ossified cochlear. Amp-I/O also depends on current intensity as well typical ECAP. These results provide a useful tool for audiological evaluation for the spiral ganglion cell status to the value of pp-ECAP.

  • PDF

A Design of 40GHz CMOS VCO (Voltage Controlled Oscillator) for High Speed Communication System (고속 통신 시스템을 위한 40GHz CMOS 전압 제어 발진기의 설계)

  • Lee, Jongsuk;Moon, Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.55-60
    • /
    • 2014
  • For an high speed communication, a 40GHz VCO was implemented using a 0.11um standard CMOS technology. The mm-wave VCO was designed by a LC type using a spiral inductor, and a simplified architecture with buffers and a smart biasing technique were used to get a high performance. The frequency range of the proposed VCO is 34~40GHz which is suitable for mm-Wave communication system. It has an output power of -16dBm and 16% tuning range. And the phase noise is -100.33dBc/Hz at 1MHz offset at 38GHz fundamental frequency. The total power consumption of VCO including PADs is 16.8mW with 1.2V supply voltage. The VCO achieves the FOMT of -183.8dBc/Hz which is better than previous VOCs.

Analysis of Direction Finding Accuracy for Amplitude-Phase Comparison and Correlative Interferometer Method (진폭-위상 복합비교 기법과 상관형 위상비교 기법의 방향탐지 정확도 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.195-201
    • /
    • 2016
  • In this paper, we present the direction finding accuracy of correlative interferometer method and amplitude-phase comparison method. Spiral antennas are used for amplitude-phase comparison method and blade antennas are used for correlative interferometer method. Those are made for uniform circular array (UCA) direction finding antenna systems. We simulate the accuracy of azimuth angle with 3 antennas UCA when SNR is 20 dB and baseline is 0.5 wave length. Correlative interferometer method has better accuracy than amplitude-phase comparison method.

Metamaterial Absorber Composed of Multi-layered Sub-wavelength Unit Cell (다층구조 서브파장 단위 셀로 구성된 메타물질 흡수체)

  • Kim, Hyung Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.31-37
    • /
    • 2020
  • In this paper, we propose a novel sub-wavelength unit cell metamaterial absorber using multi-layer structure. The proposed absorber consists of 4 layers, and each layer has a spiral resonator connected by a via hole. This structure increases inductance of the unit cell, and therefore the resonant frequency can shift to lower frequency. We optimized the proposed absorber, and the electrical size of the unit cell is dramatically reduced to 0.013 times of the wavelength. The performance of the proposed absorber is demonstrated with full-wave simulation and measurement results. An absorption rate exceeding 97% is achieved at 1.74GHz. In addition, the proposed absorber attains a high absorption rate of 90% for different polarization and incident angles.

Vertical Integrated Transformer using Bondwires (본딩와이어를 이용한 수직형 집적 트랜스포머)

  • Song, Byeong-Uk;Lee, Hae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.3
    • /
    • pp.43-48
    • /
    • 2000
  • In this paper, vortical integrated transformers using bondwires are proposed and characterized for MMIC's (Monolithic Microwave Integrated Circuits) In a wide range of frequencies (1∼20 GHz), where full-wave analysis by the FEM (Finite Element Method) was adopted. The electrical characteristics of the proposed transformers are compared with those of the spiral transformer. We extracted mutual inductances from S -parameters. The vertical transformers using bondwires have not only low insertion loss but also reduce parasitic capacitances and dielectric loss due to their separation from substrates. It can be fabricated easily by used of the modern automatic wirebonding technology. It is expected that the proposed transformers are to improve the performance of MMIC's applied to impedance matching, and phase shifting circuits.

  • PDF

Study of Blood Characteristics in Stenosed Artery under Human Body Rotation by Using FSI Method (FSI 기법을 적용한 인체 회전 시 협착 혈관에서의 혈류 특성)

  • Cho, Seong Wook;Kim, Seungwook;Ro, Kyoung Chul;Ryou, Hong Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.449-457
    • /
    • 2013
  • In this study, we performed a numerical analysis to investigate the effect of rotation on the blood flow and arterial wall behavior by using the FSI (fluid-structure interaction) technique. The geometry of the artery included 50% stenosis at the center. To simulate the rotational effect, 2-6 rps of axial velocity was applied to the arterial model. A spiral wave and asymmetric flow occurred due to the stenosis and axial rotation both in the rigid body model and in the FSI model. However, the arterial wall motion caused periodic and transient blood flow changes in the FSI model. The FRZ (fluid recirculation zone) decreased in the FSI model, which is a known predictor for the formation and vulnerability of plaque. Therefore, it is observed that arterial wall motion also influences the generation of the FRZ.

Fabrication of Microwave Applicator for Hyperthermia and Thermal Distribution in Tissues (종양의 온열치료를 위한 마이크로잔 조사장치의 제작과 응용)

  • Chu S. S.;Lee J. T.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.11-20
    • /
    • 1984
  • The renewed interest in the use of hyperthermia in cancer therapy is bases on radiobiological and clinical evidence indicated that there may be a significant therapeutic advantage with the use of heat alone or combined with radiation or chemotherapy, There are many methods for generating heat for localized tumor as like radiofrequency, microwave, electromagnetic induction and ultrasound. But it is very difficult to be even thermal dose distribution and stable output of power and then the detection of temperature in tumor is difficult to be precise with thermocouples and semiconductor sensors. We designed the microwave heating generator, dipole antenna applicators and autometic temperature controlled thermocouples for localized hyperthermia on skin and in cavities. 1. The microwave generator with 120 W, 2,450MHz magnetron could be heating up to $40^{\circ}C\~50^{\circ}C\;for\;1\~2$ hours in living tissues. 2. The thermal dose distribution in tissue with microwave was described $42^{\circ}C\~44^{\circ}C$ with in 3 cm depth and $2\~6cm$ diameter area. 3. Skin surface heating applicator with spiral 3 times wave length antenna radiated high Power of microwave. 4, Intracavitary heating applicator with dipole antenna with autometic control temperature sensor kept up continuously constant temperature in tissue. 5. For constant thermal distribution, applied two steps power with 10W microwave after $17\~20W$ during first 10 minutes. 6. The cooling rate by blood flew in living tissue was rised as $10\%$ then meats.

  • PDF