• 제목/요약/키워드: spine

검색결과 3,460건 처리시간 0.028초

The Effects of Screen Smart Devices on the Neck Flexion Angle

  • Lee, Jun Cheol;Kim, Kyung
    • 국제물리치료학회지
    • /
    • 제7권2호
    • /
    • pp.1051-1055
    • /
    • 2016
  • The purpose of this study was to investigate the effect of the screen size of smart devices on the bending angle of the cervical spine. The subjects of this study were 30 healthy adults(15 men and 15 women) who used smartphones and tablet PC(personal computer). The changes in the bending angle of the upper and lower cervical spine were measured in the subjects after they had used a smartphone and a tablet PC for 300 seconds each. To make sure that all subjects began in the same starting position, an angle-measuring instrument was used to set the angles of the ankle, knee, hip, and arm joints to 90 degree. The subjects were asked to keep the trunk straight. They were asked to hold a smartphone in their hand and to bend their neck so that they could look down at the screen. Once they began using the smartphone in this manner, they were free to change their posture. We used a paired t-test to compare the bending angle of the cervical spine on subjects who used smartphones and tablet PC in the long-term and short-term there production error of cervical and the significance level was cervical. The results showed that, when using a smartphone and a tablet PC for 300 seconds, there was no significant difference in the bending angle of the upper cervical spine(p>.05), although there was a significant difference in the bending angle of the lower cervical spine(p<.05).

척추부 촉진에 관한 연구 (The Study of Vertebral Palpation)

  • 박윤기
    • 대한정형도수물리치료학회지
    • /
    • 제16권1호
    • /
    • pp.57-63
    • /
    • 2010
  • The palpation of spinous process and transverse process of vertebra are important part of the assesment and treatment from Orthopedic manual therapy. But the palpation area is descriptive differently each of literatures. So we generally got these outcomes. : There are C2, C3, C4 and C6 process as a bony landmarks and these are important part of establish the precise location of pain appears from cervical spine. Even though C7 process regard a prominent part, it is hard to distinguish C6 and process of T1. Thru that differentiation, grab the patient's forehead and try them cervical and hyper-extension check any movement of process or put on the fingers on C7 preocess and check the movement. The palpation of thoracic spine process is the land mark which determines general level orientation in the spine easily, there are T2, T7 spinous process. However, It is depends on how do you test the patient's arm when you palpate it and it can effect on spinous process. The transverse process of C1 is the only spot for palpation in cervical spine, and T1-3, T12 transverse process can palpate it when it stands on the process. The end of T4-6, T11 is placed on middle on vertebra of transverse process and transverse process. T7-9, T10 transverse process is place on same position as spinous process which is upper part of the spine.

  • PDF

Narrative Review of Clinical Impact of Head-Hip Offset Following Adult Spinal Deformity Surgery

  • Sunho Kim;Seung-Jae Hyun;Jae-Koo Lee;Ki-Jeong Kim
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권2호
    • /
    • pp.137-145
    • /
    • 2024
  • In adult spinal deformity (ASD) surgery, mechanical failure (MF) has been a significant concern for spine surgeons as well as patients. Despite earnest endeavors to prevent MF, the absence of a definitive consensus persists, owing to the intricate interplay of multifarious factors associated with this complication. Previous approaches centered around global spinal alignment have yielded limited success in entirely forestalling MF. These methodologies, albeit valuable, exhibited limitations by neglecting to encompass global balance and compensatory mechanisms within their purview. In response to this concern, an in-depth comprehension of global balance and compensatory mechanisms emerges as imperative. In this discourse, the center of gravity and the gravity line are gaining attention in recent investigations pertaining to global balance. This narrative review aims to provide an overview of the global balance and a comprehensive understanding of related concepts and knowledge. Moreover, it delves into the clinical ramifications of the contemporary optimal correction paradigm to furnish an encompassing understanding of global balance and the current optimal correction strategies within the context of ASD surgery. By doing so, it endeavors to furnish spine surgeons with a guiding compass, enriching their decision-making process as they navigate the intricate terrain of ASD surgical interventions.

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

탑승자 교통사고에서 경추손상 판단을 위한 중증도 요인 분석 (Parameter Analysis to Predict Cervical Spine Injury on Motor Vehicle Accidents)

  • 이희영;육현;공준석;강찬영;성실;이정훈;김호중;김상철;추연일;전혁진;박종찬;최지훈;이강현
    • 자동차안전학회지
    • /
    • 제10권3호
    • /
    • pp.20-26
    • /
    • 2018
  • It was a pilot study for developing an algorithm to determine the presence or absence of cervical spine injury by analyzing the severity factor of the patients in motor vehicle occupant accidents. From August 2012 to October 2016, we used the KIDAS database, called as Korean In-Depth Accident Study database, collected from three regional emergency centers. We analyzed the general characteristics with several factors. Moreover, cervical spine injury patients were divided into two groups: Group 1 for from Quebec Task Force (hereinafter 'QTF') grade 0 to 1, and group 2 for from QTF grade 2 to 4. The score was assigned according to the distribution ratio of cervical spine injured patients compared to the total injured patients, and the cut-off value was derived from the total score by summation of the assigned score of each factors. 987 patients (53.0%) had no cervical spine injuries and 874 patients (47.0%) had cervical spine injuries. QTF grade 2 was found in 171 patients (9.2%) with musculoskeletal pain, QTF grade 3 was found in 38 patients (2.0%) with spinal cord injuries, and QTF grade 4 was found in 119 patients (6.4%) with dislocation or fracture, respectively. We selected the statistically significant factors, which could be affected the cervical spine injury, like the collision direction, the seating position, the deformation extent, the vehicle type and the frontal airbag deployment. Total score, summation of the assigned each factors, 10 was presented as a cut-off value to determine the cervical spine injury. In this study, it was meaningful as a pilot study to develop algorithms by selecting limited influence factors and proposing cut-off value to determine cervical spine injury. However, since the number of data samples was too small, additional data collection and influencing factor analysis should be performed to develop a more delicate algorithm.

Comparison of SpineJet$^{TM}$ XL and Conventional Instrumentation for Disk Space Preparation in Unilateral Transforaminal Lumbar Interbody Fusion

  • Huh, Han-Yong;Ji, Cheol;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권5호
    • /
    • pp.370-376
    • /
    • 2010
  • Objective : Although unilateral transforaminal lumbar interbody fusion (TLIF) is widely used because of its benefits, it does have some technical limitations. Removal of disk material and endplate cartilage is difficult, but essential, for proper fusion in unilateral surgery, leading to debate regarding the surgery's limitations in removing the disk material on the contralateral side. Therefore, authors have conducted a randomized, comparative cadaver study in order to evaluate the efficiency of the surgery when using conventional instruments in the preparation of the disk space and when using the recently developed high-pressure water jet system, SpineJet$^{TM}$ XL. Methods : Two spine surgeons performed diskectomies and disk preparations for TLIF in 20 lumbar disks. All cadaver/surgeon/level allocations for preparation using the SpineJet$^{TM}$ XL (HydroCision Inc., Boston, MA, USA) or conventional tools were randomized. All assessments were performed by an independent spine surgeon who was unaware of the randomizations. The authors measured the areas (cm2) and calculated the proportion (%) of the disk surfaces. The duration of the disk preparation and number of instrument insertions and withdrawals required to complete the disk preparation were recorded for all procedures. Results : The proportion of the area of removed disk tissue versus that of potentially removable disk tissue, the proportion of the area of removed endplate cartilage, and the area of removed disk tissue in the contralateral posterior portion showed 74.5 ${\pm}$ 17.2%, 18.5 ${\pm}$ 12.03%, and 67.55 ${\pm}$ 16.10%, respectively, when the SpineJet$^{TM}$ XL was used, and 52.6 ${\pm}$ 16.9%, 22.8 ${\pm}$ 17.84%, and 51.64 ${\pm}$ 19.63%, respectively, when conventional instrumentations were used. The results also showed that when the SpineJet$^{TM}$ XL was used, the proportion of the area of removed disk tissue versus that of potentially removable disk tissue and the area of removed disk tissue in the contralateral posterior portion were statistically significantly high (p < 0.001, p < 0.05, respectively). Also, compared to conventional instrumentations, the duration required to complete disk space preparation was shorter, and the frequency of instrument use and the numbers of insertions/withdrawals were lower when the SpineJet$^{TM}$ XL was used. Conclusion : The present study demonstrates that hydrosurgery using the SpineJet$^{TM}$ XL unit allows for the preparation of a greater portion of disk space and that it is less traumatic and allows for more precise endplate preparation without damage to the bony endplate. Furthermore, the SpineJet$^{TM}$ XL appears to provide tangible benefits in terms of disk space preparation for graft placement, particularly when using the unilateral TLIF approach.

요추 척추관 협착증 환자 118례에 대한 임상적 고찰 (The Clinical Study on Spinal Stenosis of Lumbar Spine)

  • 조재희;이효은;문자영;임명장;강인;이한;정호석;김지형
    • 척추신경추나의학회지
    • /
    • 제3권2호
    • /
    • pp.77-85
    • /
    • 2008
  • Object : These studies are designed to make a survey of the effectiveness of the non surgical oriental medicine treatment with Chuna on spinal stenosis of lumbar spine. Methods : The clinical study was done on 118 cases of patients with spinal stenosis of lumbar spine diagnosed by M.R.I, symptoms and physical test who was in the admission in Ja-Seng Oriental Medcine Hospital from October 2006 to October 2008. after treatment we checked VNRS score to estimate the efficacy of treatment. Results : 1. As a Objectivity treatment record, they test excellent 17%, good 69%, fair 8%, poor 6%. 2. The mean NRS score decreased about 3.26 after the treatment. Conclusions : Non surgical oriental medicine treatment with Chuna has on useful effect on spinal stenosis of lumbar spine.

  • PDF

대용량약침 및 한방치료를 적용한 요추 추간판 탈출증 환자 치험 3례, 경추 추간판 탈출증 환자 치험 1례 (A Clinical Case Report Treated by Megadose Pharmacoacupuncture and Korean Medical treatments for the three Patients with HIVD of L-Spine and one Patient with HIVD of C-Spine)

  • 주영국;김태호;이소진;안상민;신수지;권옥준;김주원;윤문식
    • 척추신경추나의학회지
    • /
    • 제10권2호
    • /
    • pp.61-71
    • /
    • 2015
  • Objective : To report cases of HIVD of C&L-Spine successfully treated with conservative Korean Traditional Medicine treatment with Megadose Pharmacoacupuncture. Methods : Four patients diagnosed with HIVD of C&L-Spine were treated with Megadose Pharmacopuncture, acupuncture and herbal medicine. Numeric Rating Scale(NRS), Neck Disablility Index(NDI) and Oswestry low back pain Disablility Index(ODI) scores were collected before and after treatment for comparison. Results : There was a significant decrease in NRS, NDI and ODI scores. The mean NRS score decresed from 9 to 2.25, NDI from 45 to 14 and ODI from 46.66 to 11.33. Conclusion : The result suggests Megadose Pharmacoacupuncture can be an effective treatment on patients with HIVD of C&L-Spine.

Interobserver and Intraobserver Reliability of Sub-Axial Injury Classification and Severity Scale between Radiologist, Resident and Spine Surgeon

  • Lee, Woo Jin;Yoon, Seung Hwan;Kim, Yeo Ju;Kim, Ji Yong;Park, Hyung Chun;Park, Chon Oon
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권3호
    • /
    • pp.200-203
    • /
    • 2012
  • Objective : The sub-axial injury classification (SLIC) and severity scale was developed to decide whether to operate the cervical injured patient or not, but the reliability of SLIC and severity scale among the different physicians was not well known. Therefore, we evaluated the reliability of SLIC among a spine surgeon, a resident of neurosurgery and a neuro-radiologist. Methods : In retrograde review in single hospital from 2002 to 2009 years, 75 cases of sub-axial spine injured patients underwent operation. Each case was blindly reviewed for the SLIC and severity scale by 3 different observers by two times with 4 weeks interval with randomly allocated. The compared axis was the injury morphology score, the disco-ligamentous complex score, the neurological status score and total SLIC score; the neurological status score was derived from the review of medical record. The kappa value was used for the statistical analysis. Results : Interobserver agreement of SLIC and severity scale was substantial agreement in the score of injury morphology [intraclass correlation (ICC)=0.603] and total SLIC and severity sacle (ICC value=0.775), but was fair agreement in the disco-ligamentous complex score (ICC value= 0.304). Intraobserver agreements were almost perfect agreement in whole scales with ICC of 0.974 in a spine surgeon, 0.948 in a resident of neurosurgery, and 0.963 in a neuro-radiologist. Conclusion : The SLIC and severity scale is comprehensive and easily applicable tool in spine injured patient. Moreover, it is very useful tool to communicate among spine surgeons, residents of neurosurgery and neuro-radiologists with sufficient reproducibility.

The Change of Adjacent Segment and Sagittal Balance after Thoracolumbar Spine Surgery

  • Kim, Kang-San;Hwang, Hyung-Sik;Jeong, Je-Hoon;Moon, Seung-Myung;Choi, Sun-Kil;Kim, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권5호
    • /
    • pp.437-442
    • /
    • 2009
  • Objective : To characterize perioperative biomechanical changes after thoracic spine surgery. Methods : Fifty-eight patients underwent spinal instrumented fusions and simple laminectomies on the thoracolumbar spine from April 2003 to October 2008. Patients were allocated to three groups; namely, the laminectomy without fusion group (group I, n = 17), the thoracolumbar fusion group (group II, n = 27), and the thoracic spine fusion group (group III, n = 14). Sagittal (ADS) and coronal (ADC) angles for adjacent segments were measured from two disc spaces above lesions at the upper margins, to two disc spaces below lesions at the lower margins. Sagittal (TLS) and coronal (TLC) angles of the thoracolumbar junction were measured from the lower margin of the 11th thoracic vertebra body to the upper margin of the 2nd lumbar vertebra body on plane radiographs. Adjacent segment disc heights and disc signal changes were determined using simple spinal examinations and by magnetic resonance imaging. Clinical outcome indices were determined using a visual analog scale. Results : The three groups demonstrated statistically significant differences in terms of angle changes by ANOVA (p<0.05). All angles in group I showed significantly smaller angles changes than in groups II and III by Turkey's multiple comparison analysis. Coronal Cobb's angles of the thoracolumbar spine (TLC) were not significantly different in the three groups. Conclusion : Postoperative sagittal balance is expected to change in the adjacent and thoracolumbar areas after thoracic spine fusion. However, its prevalence seems to be higher when the thoracolumbar spine is included in instrumented fusion.