Foreign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion

  • Seo, Jun-Yeong;Ha, Kee-Yong;Kim, Young-Hoon;Ahn, Joo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권6호
    • /
    • pp.647-649
    • /
    • 2016
  • The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against a DIAM. A 72-year-old female patient presented with lower back pain and both legs radiating pain. She had undergone DIAM implantation at L4-5 for spinal stenosis 5 years previously. The intervertebral disc space of L4-5, where the DIAM was inserted, had collapsed and degenerative scoliosis had developed due to left-side collapse. MRI showed L3-4 thecal sac compression and left L4-5 foraminal stenosis. The patient underwent removal of the DIAM and instrumented fusion from L3 to L5. During surgery, fluid and granulation tissue were evident around the DIAM. Histopathology showed scattered wear debris from the DIAM causing chronic inflammation due to the resulting FBR. A FBR due to wear debris of a DIAM can induce a hypersensitivity reaction and bone resorption around the implant, causing it to loosen.

Cervical Open-Door Laminoplasty by Hydroxyapatite Implant Insertion Without Suturing

  • Kawanabe, Yoshifumi;Fujimoto, Motoaki;Sato, Tsukasa
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.362-367
    • /
    • 2018
  • Objective: To assess the efficacy of cervical open-door laminoplasty by hydroxyapatite implant insertion between the lamina and the lateral mass without suturing. Methods: All patients who underwent cervical open-door laminoplasty with C2/C7 undermining and insertion of hydroxyapatite implants from C3 to C6 were retrospectively evaluated for surgical time and neurological outcomes according to the Japanese Orthopaedic Association (JOA) score. To assess the alignment of the cervical spine and postoperative cervical pain, the C2-7 angle and a visual analogue scale score were used, respectively. Results: The population consisted of 102 women and 222 men ranging in age from 32 to 90 years. The average surgical time was 86 minutes. Fourteen of 1,296 hydroxyapatite implants were kept in place with sutures due to a weak restoration force of the hinge during surgery. No hydroxyapatite implant dislocation was detected on cervical computed tomography at 1 year after surgery. The average JOA score was $10.2{\pm}2.5$ before surgery and $14.6{\pm}2.8$ at 1 year after surgery. The average recovery rate was 61.8%. The average C2-7 angle at the neutral position was $7.1^{\circ}{\pm}6.2^{\circ}$ before surgery and $6.5^{\circ}{\pm}6.3^{\circ}$ at 1 year after surgery. Conclusion: This method enabled us to achieve minimal exposure of the lateral mass, prevention of lateral mass injury and dural injury, and a shorter surgical time while maintaining acceptable surgical outcomes. The idea that firm suture fixation is needed to prevent spacer deviation during cervical open-door laminoplasty may need to be revisited.

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권6호
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

인공 추간판 적용으로 인한 인접 운동 분절의 영향 (Effects on the Adjacent Motion Segments according to the Artificial Disc Insertion)

  • 김영은;윤상석
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.122-129
    • /
    • 2007
  • To evaluate the effect of artificial disc implantation and fusion on the biomechanics of adjacent motion segment, a nonlinear three-dimensional finite element model of whole lumbar spine (L1-S1) was developed. Biomechanical analysis was performed for two different types of artificial disc, ProDisc and SB $Charit{\acute{e}}$ III model, inserted at L4-L5 level and these results were also compared with fusion case. Angular motion of vertebral body, forces on the spinal ligaments and facet joint under sagittal plane loading with a compressive preload of 150 N at a nonlinear three-dimensional finite element model of Ll-S1 were compared. The implant did not significantly alter the kinematics of the motion segment adjacent to the instrumented level. However, $Charit{\acute{e}}$ III model tend to decrease its motion on the adjacent levels, especially in extension motion. Contrast to motion and ligament force changes, facet contact forces were increased in the adjacent levels as well as implanted level for constrained instantaneous center of rotation model, i.e. ProDisc model.

인공 추간판 치환술 후 경추의 생체역학적 특성 (Biomechanical Characteristics of Cervical Spine After Total Disc Replacement)

  • 박원만;주증우;김경수;이기석;김윤혁
    • 대한기계학회논문집A
    • /
    • 제33권7호
    • /
    • pp.637-644
    • /
    • 2009
  • We have analyzed the biomechanical characteristics of cervical spine after total disc replacement using finite element analysis. A finite element model of C2-C7 spinal motion segment was developed and validated by other experimental studies. Two types of artificial discs, semi-constraint and un-constraint, were inserted at C6-C7 segments. Inferior plane of C7 vertebra was fixed and 1Nm of moment were applied on superior plane of C2 vertebra with 50N of compressive load along follower load direction. Mobility of the cervical spine in which each artificial disc inserted was higher than that of intact one in all loading conditions. Also, high mobility at the surgical level after total disc replacement could lead higher facet joint force and ligaments axial stresses. The results of present study could be used to evaluate surgical option and validate the biomechanical characteristics of the implant in total disc replacement in cervical spine.

The Option of Motion Preservation in Cervical Spondylosis: Cervical Disc Arthroplasty Update

  • Chang, Chih-Chang;Huang, Wen-Cheng;Wu, Jau-Ching;Mummaneni, Praveen V.
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.296-305
    • /
    • 2018
  • Cervical disc arthroplasty (CDA), or total disc replacement, has emerged as an option in the past two decades for the management of 1- and 2-level cervical disc herniation and spondylosis causing radiculopathy, myelopathy, or both. Multiple prospective randomized controlled trials have demonstrated CDA to be as safe and effective as anterior cervical discectomy and fusion, which has been the standard of care for decades. Moreover, CDA successfully preserved segmental mobility in the majority of surgical levels for 5-10 years. Although CDA has been suggested to have long-term efficacy for the reduction of adjacent segment disease in some studies, more data are needed on this topic. Surgery for CDA is more demanding for decompression, because indirect decompression by placement of a tall bone graft is not possible in CDA. The artificial discs should be properly sized, centered, and installed to allow movement of the vertebrae, and are commonly 6 mm high or less in most patients. The key to successful CDA surgery includes strict patient selection, generous decompression of the neural elements, accurate sizing of the device, and appropriately centered implant placement.

Clinical Experiences and Usefulness of Cervical Posterior Stabilization with Polyaxial Screw-Rod System

  • Hwang, In-Chang;Kang, Dong-Ho;Han, Jong-Woo;Park, In-Sung;Lee, Chul-Hee;Park, Sun-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권4호
    • /
    • pp.311-316
    • /
    • 2007
  • Objective : The objective of this study is to investigate the safety, surgical efficacy, and advantages of a polyaxial screw-rod system for posterior occipitocervicothoracic arthrodesis. Methods : Charts and radiographs of 32 patients who underwent posterior cervical fixation between October 2004 and February 2006 were retrospectively reviewed. Posterior cervical polyaxial screw-rod fixation was applied on the cervical spine and/or upper thoracic spine. The surgical indication was fracture or dislocation in 18, C1-2 ligamentous injury with trauma in 5, atlantoaxial instability by rheumatoid arthritis (RA) or diffuse idiopathic skeletal hyperostosis (DISH) in 4, cervical spondylosis with myelopathy in 4, and spinal metastatic tumor in 1. The patients were followed up and evaluated based on their clinical status and radiographs at 1, 3, 6 months and 1 year after surgery. Results : A total of 189 screws were implanted in 32 patients. Fixation was carried out over an average of 3.3 spinal segment (range, 2 to 7). The mean follow-up interval was 20.2 months. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-7 lateral masses, as well as the lower cervical and upper thoracic pedicles. Satisfactory bony fusion and reduction were achieved and confirmed in postoperative flexion-extension lateral radiographs and computed tomography (CT) scans in all cases. Revision surgery was required in two cases due to deep wound infection. One case needed a skin graft due to necrotic change. There was one case of kyphotic change due to adjacent segmental degeneration. There were no other complications, such as cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, or implant failure, and there were no cases of postoperative radiculopathy due to foraminal stenosis. Conclusion : Posterior cervical stabilization with a polyaxial screw-rod system is a safe and reliable technique that appears to offer several advantages over existing methods. Further biomechanical testings and clinical experiences are needed in order to determine the true benefits of this procedure.

Can the Zero-Profile Implant Be Used for Anterior Cervical Discectomy and Fusion in Traumatic Subaxial Disc Injury? A Preliminary, Retrospective Study

  • Kim, Tae Hun;Kim, Dae Hyun;Kim, Ki Hong;Kwak, Young Seok;Kwak, Sang Gyu;Choi, Man Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권5호
    • /
    • pp.574-581
    • /
    • 2018
  • Objective : The zero-profile implant (Zero-P) is accepted for use in anterior cervical fusion for the treatment of degenerative cervical disease. However, evidence pertaining to its efficiency and safety in traumatic cervical injury is largely insufficient. This study aimed to compare the overall outcomes of patients who underwent Zero-P for traumatic cervical disc injury. Methods : Data from a total of 53 consecutive patients who underwent surgery for traumatic or degenerative cervical disc disease using the Zero-P were reviewed. Seventeen patients (group A) had traumatic cervical disc injury and the remaining 36 (group B) had degenerative cervical disc herniation. The fusion and subsidence rates and Cobb angle were measured retrospectively from plain radiographs. The patients' clinical outcomes were evaluated using the Japanese Orthopedic Association (JOA) score and Odom's criteria. Results : The C2-7 Cobb and operative segmental angles increased by $3.45{\pm}7.61$ and $2.94{\pm}4.59$ in group A; and $2.46{\pm}7.31$ and $2.88{\pm}5.49$ in group B over 12 postoperative months, respectively. The subsidence and fusion rate was 35.0% and 95.0% in group A; and 36.6% and 95.1% in group B, respectively. None of the parameters differed significantly between groups. The clinical outcomes were similar in both groups in terms of increasing the JOA score and producing a grade higher than "good" using Odom's criteria. Conclusion : The application of Zero-P in patients with traumatic cervical disc injury was found to be acceptable when compared with the clinical and radiological outcomes of degenerative cervical spondylosis.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

요추유합술에서 응력방패 현상 감소를 위한 케이지의 유한요소해석 : CFRP 케이지와 티타늄 케이지 비교 연구 (Finite Element Analysis of Instrumented Posterior Lumbar Interbody Fusion Cages for Reducing Stress Shielding Effects: Comparison of the CFRP cage and Titanium cage)

  • 강경탁;전흥재;김호중;염진섭;박경미;황인한;이광일
    • Composites Research
    • /
    • 제25권4호
    • /
    • pp.98-104
    • /
    • 2012
  • 본 논문에서는 척추체 간 유합용 케이지의 응력방패현상을 감소시키기 위하여 강성 차이에 대한 연구를 수행하였다. 최근 의료 임플란트 분야에서는 탄소섬유강화 폴리머를 이용하여 좋은 결과를 보여 왔다. 그러나 생체 역학적으로 이 재료에 대하여 요추체의 안정성과 골 이식재가 받는 응력에 관련한 연구는 없었다. 따라서 이전에 유효화한 요추체 (L2-L5) 비선형 유한 요소 모델을 이용하여 L4-L5 분절의 케이지의 강성 차이에 따른 효과를 알아보기 위하여 탄소섬유강화 폴리머와 티타늄 케이지를 이용한 후방 요추체 유합 모델을 만들었다. 자가골 보다 강성이 작은 탄소 섬유강화폴리머 케이지는 인접 분절의 하종판에 응력이 적게 걸리며, 골 이식재에 응력은 증가시켰다. 위의 결과로 탄소섬유강화 폴리머 케이지는 응력 방패 현상을 감소시킬 수 있을 뿐만 아니라 골 유합률을 증가시킬 수 있다.