• 제목/요약/키워드: spectral power distribution

검색결과 134건 처리시간 0.034초

동적 LED 시스템의 조명원적 성능분석 (Evaluation on the lighting performance of a dynamic LED lighting system)

  • 김효인;김정태;윤근영
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.113-119
    • /
    • 2011
  • LED lighting has received much attention in recent years due to its high energy efficiency and environmental friendliness. As the color of light can be obtained by adjusting the light intensity of LEDs, the quality of visual environment can be improved. The aims of this study are to develop a wavelength adjustable LED lighting system and to examine its lighting performances. The LED lighting system and experimental cell for assessment of the lighting performance were constructed. This LED lighting system is able to materialize the various spectral power distribution and color temperature of light through the control of the four dimmers. Up to $432^4$ kinds of light combinations are possible. The range of illuminance on workplane were measured as 7~1,831 ㏓. Improvement of psychological and physical functions for occupants can be expected according to control of lighting performances.

요분석 스트립의 정색반응에 대한 색도좌표 보정 (The Compensation of Chromaticity Coordinates on Primary Color Reaction of Urine Strips)

  • 김재형;조진욱;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.320-323
    • /
    • 2001
  • A computer simulation was performed to distinguish quantitatively a color reaction in a urine analysis systems by using the spectral power distribution of LEDs. the spectral reflectance of a urine strip. and the spectral sensitivity of photodiode. The CIE tristimulus values and CIE chromaticity coordinates ware modified to be conformable with real color reactions in a urine strips. Results on color simulation showed a of real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

소형 칼라미터의 개발에 관한 연구 (Development of a Portable Colorimeter)

  • 김재형;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.328-331
    • /
    • 2001
  • Color simulation on a portable colorimeter was performed to distinguish quantitatively a chromaticity coordinates on a color guide of a urine strips by using the spectral power distribution of chip LED, the spectral reflectance of printed objects, and the spectral sensitivity of photodiode. The CIE tristimulus values and chromaticity coordinates realized by a colorimeter were modified to be conformable with real color reactions. Experimental results showed a real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

식물생장용 고압나트륨램프와 메탈할라이드램프의 분광 광강도 분석 (Analysis of Spectral Light Intensity of High Pressure Sodium and Metal Halide Lamps for Plant Growth)

  • 이혜인;김용현;김동억
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.413-419
    • /
    • 2010
  • Plant growth was greatly affected by the spectral distribution and light intensity of artificial lighting sources. In this study, the spectral characteristics of high power sodium (HPS) lamps and metal halide (MH) lamps produced by three different manufacturers were measured. Even though the spectral distribution of HPS lamps with lamp wattage of 250 W and 400 W was very similar, but the spectral light intensity by the manufacturers was different. Difference in the spectral light intensity of MH lamps by the manufacturers was increased with the increasing lamps wattage. Light intensity at the region of blue (B), green (G), red (R) and far-red (FR) light of HPS and MH lamps was also analyzed. HPS lamps showed the light intensity in order of R, FR, B and G light. The ratio of G, B, R and FR to photosynthetic photon flux (PPF) of HPS lamps with the lamp wattage of 250 W was 3.0-3.2%, 5.5-5.9%, 17.3-19.2% and 6.5-7.8%, respectively. For MH lamps, it showed the light intensity in order of R, FR, B, and G. The ratio of B, G, R, and FR to PPF of MH lamps with 250 W was 14.0-15.5%, 22.6-27.5%, 7.5-9.5% and 2.7-4.2%, respectively. HPS and MH lamps with 400 W had a relatively smaller ratio of R and FR to PPF than those with 250 W. HPS lamps showed that the ratio of light intensity of B and FR to R was 0.15-0.28 and 0.36-0.4, respectively. For MH lamps, the ratio of light intensity of B and FR to R was 1.26-2.72 and 0.27-0.56, respectively. From these results, it was concluded that the portion of blue light of MH lamps was higher than those of HPS lamps.

Characterizing and modelling nonstationary tri-directional thunderstorm wind time histories

  • Y.X. Liu;H.P. Hong
    • Wind and Structures
    • /
    • 제38권4호
    • /
    • pp.277-293
    • /
    • 2024
  • The recorded thunderstorm winds at a point contain tri-directional components. The probabilistic characteristics of such recorded winds in terms of instantaneous mean wind speed and direction, and the probability distribution and the time-frequency dependent crossed and non-crossed power spectral density functions for the high-frequency fluctuating wind components are unclear. In the present study, we analyze the recorded tri-directional thunderstorm wind components by separating the recorded winds in terms of low-frequency time-varying mean wind speed and high-frequency fluctuating wind components in the alongwind direction and two orthogonal crosswind directions. We determine the time-varying mean wind speed and direction defined by azimuth and elevation angles, and analyze the spectra of high-frequency wind components in three orthogonal directions using continuous wavelet transforms. Additionally, we evaluate the coherence between each pair of fluctuating winds. Based on the analysis results, we develop empirical spectral models and lagged coherence models for the tri-directional fluctuating wind components, and we indicate that the fluctuating wind components can be treated as Gaussian. We show how they can be used to generate time histories of the tri-directional thunderstorm winds.

가상 심장박동 발진기를 활용한 심박변이도 해석 (Interpretation of HRV by the Coupled-Oscillating Cardiac Control System)

  • 정겨운;김정환;이준우;김경섭
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.493-498
    • /
    • 2016
  • Heart Rate Variability (HRV) represents beat-to-beat fluctuations of R-R intervals in Electrocardiogram (ECG). On of the clinical applications of HRV is to assess the mental-stress state by evaluating its power spectral density distribution. This study aims at finding new discriminative role of the coupled-oscillating coupling constants, Cs and Cp in the Integral Pulse Frequency Modulation (IPFM) model. Based on comparing with power spectral density of HRV in terms of the relative ratio of the low and high-frequency power component, we can conclude the fact that the coupling parameters Cs and Cp can replace the role of HRV power spectrum interpretation for judging the mental-stress state.

배전계통(配電系統) 돌입전류(突人電流) 검출(檢出) 알고리즘에 관(關)한 연구(硏究) (A Study on the Inrush Current Detect Algorithm in Power Distribution System)

  • 윤만철;권욱현;이기원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.449-453
    • /
    • 1987
  • This paper presents the detecting algorithm of inrush current which causes protective equipment to maloperate in energizing a power distribution line. This detecting algorithm uses the method which extracts the decay component and energy of 2nd harmonics by Prony Spectral Estimation Method existed AR model to new ARMA model. In this paper, the inrush currents are obtained by model simulations and fild tests. By applying these data to the detecting algorithm, it has been confirmed to discriminate inrush currents from fault currents.

  • PDF

뇌파의 한의학적 진단 지표로의 활용 방안에 대한 연구초안 (The methodology on the application of EEG as a diagonostic measures in Korean Traditional Medicine)

  • 서영효;김경철;김보경
    • 동의신경정신과학회지
    • /
    • 제18권1호
    • /
    • pp.37-61
    • /
    • 2007
  • Objective : By examining EEG status in Korean Traditional Medicine (KTM) from the viewpoint of 'form-qi theory(形氣論)', We wish to prepare for the fundamentals of applicability of KTM diagnoses to EEG. In addition, through reinterpretation of existing Western Medicine reports from the viewpoint of KTM, We tried to find out interrelationship between them. Method : In this paper, a methodology applicable to KTM diagnoses of EEG is presented from the EEG features in waveform characteristics, personalized diversity, and cognitive activity reflection. Results : Frequency bands are assigned to corresponding one of the eight trigrams in terms of yin/yang balance, which is analogous with EEG spectrum analysis mostly used in EEG quantification. The amplitude ratio of each EEG for each frequency band gives meaningful index numbers which can be used in EEG data interpretation, and every index number is named after the sixty four hexagrams. These approaches are adopted through both '4-band classification system and '6-band classification system', and applied to pre-existing reported EEG data obtained from normal adults. These analyses show that changes and distribution pattern in the index numbers are observed as a whole on both left-right line and front-back line connecting EEG measurement cephalic electrodes. And differences in distribution pattern of three index numbers deduced from '6-band classification system' are discussed according to constitution. Conclusion : The index numbers introduced here, which are the spectral power ratio for each EEG, are based on KTM yin/yang balance. These index numbers vary according to cephalic location, so its application in terms of traditional meridian theory is strongly expected. The index number distribution also shows different patterns according to constitution.

  • PDF

Radiation mechanism of gamma-ray burst prompt emission

  • 엄정휘
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.49.3-50
    • /
    • 2015
  • Synchrotron radiation of relativistic electrons is an important radiation mechanism in many astrophysical sources. In the sources where the synchrotron cooling timescale is shorter than the dynamical timescale, electrons are cooled down below the minimum injection energy. It has been believed that such fast-cooling electrons have a power-law distribution in energy with an index -2, and their synchrotron radiation has a photon spectral index -1.5. On the other hand, in a transient expanding astrophysical source, such as a gamma-ray burst (GRB), the magnetic field strength in the emission region continuously decreases with radius. Here we study such a system, and find that in a certain parameter regime, the fast-cooling electrons can have a harder energy spectrum. We apply this new physical regime to GRBs, and suggest that the GRB prompt emission spectra whose low-energy photon spectral index has a typical value -1 could be due to synchrotron radiation in this moderately fast-cooling regime.

  • PDF

파장가변 Ti:sapphire 레이저의 협대역 특성 (Spectrum Narrowing Characteristics of a Tunable Ti:sapphire Laser)

  • 이용우;이주희
    • 한국광학회지
    • /
    • 제6권1호
    • /
    • pp.16-20
    • /
    • 1995
  • 본 논문은 Nd:YAG 레이저의 제2고조파로 펄스 펌핑된 파장가변형 Ti:sapphire 레이저의 협대역 특성을 연구하였다. Ti:sapphire 레이저는 rod의 양단에서 펌핑하여 균일한 여기 분포를 갖도록 하였고, 공진기의 격자를 선형적으로 제어하여 705-835nm의 넓은 범위에서 연속적인 파장 선택을 실현하였다. 이때 회절격자 제어계의 분해각은 0.27"/pulse이다. 중심파장 790nm때 출력 에너지는 $380{\mu}J$, 레이저 출력이 최대 출력의 50% 이상되는 파장 범위는 730-825nm, 스펙트럼 선폭은 $0.13cm_{-1}$, 빔 발산각은 1.2mrad을 각각 얻었다.

  • PDF