• Title/Summary/Keyword: specimen condition

Search Result 1,167, Processing Time 0.022 seconds

Elastic Work Factor of CLS Specimen and Determination of $G_c$ for Graphite/Peek Composites by Using the Elastic Work Factor (CLS 시편의 탄성일인자 유도 및 이를 적용한 열가소성 Graphite/Peek 복합재의 파괴인성 $G_c$ 측정)

  • Lee, Gyeong-Yeop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.9
    • /
    • pp.2792-2799
    • /
    • 1996
  • It was shown in the previous study that the numerically derived elastic work factor for CLS specimen was independent of fiber direction for a unidirectional case. Also, it was proposed the elastic work factor could be used to determine energy release rate from a single test record. In the present study, elastic work factor was derived from a simple beam theory to investigate its dependence on material property and geometric condition. Also, the elastic work factor of CLS specimen was applied experimentally to determine critical energy release rate in order to prove its validity determining critical energy release rate from a single specimen. For this purpose, critical energy release rate determined using the elastic work factor was compared with that determined by the compliance method. The results showed that while elastic work factor is affected by $t_2/t_1$ and $L_2/L_1$ it is independent of fiber angle for a unidirectional case. It was also found that critical energy release rates determined by both methods are comparable each other, thus elastic work factor approach can be used to determine energy release rate from a single test specimen.

The Estimation of Mechanical Properties of the High Frequency Induction Hardening SM45C Steel by Acoustic Emission (음향방출법에 의한 SM45C 고주파 열처리 강의 기계적 특성 평가)

  • Rhee, Zhang-Kyu;Kim, Bong-Gag
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.471-481
    • /
    • 2009
  • This study is deal with the high frequency induction hardening (HF at $850^{\circ}C$, 120kHz & 50kW condition) SM45C steel. (1) The HF specimen which was tempered at $150^{\circ}C$, did not appear any tempering effect. A brittle fracture occurred at rounded area of the tensile specimen. AE amplitude distribution showed between 45~60dB. (2) The HF specimen which was tempered at $300^{\circ}C$, slip and fracture occurred at the hole area of the tensile specimen. As it passes the yield point, the AE energy increased intermittently and AE amplitude distribution showed between 70~85dB. In addition, after the maximum tensile load, it showed high amplitude and energy distribution. The AE amplitude showed between 45~70dB. (3) The HF specimen which was tempered at $450^{\circ}C$, a brittle fracture occurred as if it is torn in the direction of $45^{\circ}$ on parallel area over the both sides of the tensile specimen, which led to several peak to be appeared in AE energy. It was found that the AE amplitude was relatively low and the AE energy was high.

  • PDF

Effect of specimen thickness on fatigue crack growth and retardation behavior of 7075-T73 aluminum alloy (7075-T73 알루미늄 합금의 피로균열진전거동 및 지연현상에 미치는 두께의 영향)

  • 김정규;박병훈;류석현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.670-679
    • /
    • 1989
  • The constant amplitude loading and 100% single overloading fatigue studies of domestic high tensile 7075-T73 aluminum alloy were performed to exmine the effect of specimen thickness and its mechanisms on fatigue crack growth behavior. The stage II fatigue crack growth rates tend to increase with decreasing specimen thickness under constant amplitude loading condition and this has relation with stress intensity factors and plastic zone size. The amount of retardation by an overload increased with decreasing specimen thickness when the crack depth and baseline stress intensity factors were constant. The crack depth is one of major factors which affect retardation phenomena by an overload and the amount of retardation increase with decreasing the crack depth. Its main mechanisms are crack closure and decreasing of K at the crack tip by branching and deflection of crack. And they are affected by near surface more severely than central portion of specimen.

Characteristics of AE Signals of Matrix Cracks in Composites Due to the Different Specimen Shapes (시편 형상에 따른 복합재료의 모재균열 신호특성)

  • 방형준;박상욱;김천곤;홍창선
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.39-43
    • /
    • 2002
  • As the concept of the smart structure, monitoring of acoustic emission (AE) can be applied to inspect the fracture of the entire structure in operating condition using built-in sensors. The objective of this study is to find the characteristics of matrix crack signals in composites due to the different specimen shapes. To detect matrix crack signals, we performed tensile tests by changing the thickness, width and length of the specimen. For the quantitative evaluation, time frequency analysis such as short-time Fourier transform (STFT) was used to characterize the matrix crack signals from PZT sensor. The experimental result shows the distinctive signal features in frequency domain due to the different specimen shapes.

  • PDF

A Study on the Speciman For High Speed Machining (고속가공을 위한 검사시편에 관한 연구)

  • 정종윤;황영수;이춘만;정원지;고태조
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.77-84
    • /
    • 2003
  • The properties of a machine tool greatly affect machining quality since a machine tool has large variance in its features. Machine tool makers want to find best machining condition with the one that they have built. Machine builders need to develop test specimen since it helps finding characteristics of machine tools when the machining properties of the specimen are analyzed. This paper develops test specimen to identify features of the main spindle, the feeding device, and the frame of a machine tool. The specimen is machined with a high speed machine and the features of the machine are analyzed with test items. They are surface roughness, overshoot in axial movement, errors in circular movement, feeding with small movement and compensational error. This work can improve usability for a machine tool in machining practice.

The Changes of Electron Microscopic Block Condition According to Seasonal Status (계절에 따른 Electron Microscopic Block 상태의 변화)

  • Sohn, Seong-Hyang;Yoo, Chang-Kyu;Choe, Rim-Soon
    • Applied Microscopy
    • /
    • v.19 no.2
    • /
    • pp.138-144
    • /
    • 1989
  • The specimens for electron microscopic observation made in different seasons have different qualities even though they are made by the same procedure. We observed the various specimens made in each four season. As the results, we concluded that the different specimen conditions were caused by the humidity and penetrability of various solution into the block. In spring, fall and winter, the quality of specimen is good and the difference with one another is not found. But in summer, the specimen have worse quality than in other seasons and not good for sectioning process and observation. In summer with high humidity, we can gain better specimens by eliminating the humidity as much as possible in all processes, thus increasing penetration of various solutions into the specimen.

  • PDF

Temperature and Compressive Strength Characteristics According to the Sealing Curing Method at a Curing Temperature of 5℃ (양생온도 5℃에서 봉함양생방법에 따른 콘크리트의 온도 및 압축강도 특성)

  • Bae, Ki-Hun;Park, Jun-Hyoung;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.131-132
    • /
    • 2021
  • According to the domestic specification, the curing of the specimen for strength management used to determine the time of the mold deformity of the structure concrete in early spring and early autumn is cured in the field structure condition. However, when the seal curing is performed in the field, the temperature of the specimen is very low compared to the temperature of the actual structure, so the strength of the structure concrete predicted based on the strength of the specimen is much undervalued than the actual one, which causes the mold to be deformed. Therefore, this study analyzed the temperature history and compressive strength characteristics of the specimen for strength management through other sealing curing at 5℃ and concrete of the actual structure, and presented the most suitable curing method.

  • PDF

An Experimental Study on the Compressive Strength of High Strength Concrete According to Testing Condition (시험조건과 고강도콘크리트의 압축강도 관계에 관한 실험적 연구)

  • Chin, Young-Gil;Lee, Yong-Su;Kim, Kwang-Seo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.2
    • /
    • pp.129-134
    • /
    • 2002
  • The strength and durability of concrete are affected by various factors such as the quality of material, mixing ratio, construction, the method of cure, time elapsed. the condition of test and etc., it is very difficult to pre-estimate the strength of concrete with the use of experimental specimen. The domestic standard of specimen cylindrical type and its sizes are both l0cm$\times$20cm and 15cm$\times$30cm, which are prescribed in KS F2405, and the loading speed is prescribed to test with 2~3kgf/$\textrm{cm}^2$ per second. The loading speed should have great effect on the compressive strength, but in reality in the construction site sometimes the loading speed is applied so dubiously that the value of the compressive strength can be unreliable. And the cross sectional area of a specimen should be level and smooth, otherwise it can be broken at a lower stress than the real strength through the eccentric or intensive working of the load. Capping should be carried out in order to measure the strength correctly. And used for capping are various materials such as capping compound, cement glue, plaster, mechanical grinding and etc. In this study, therefore, I have carried out an experiment on the relationship among the loading speed, the ratio of height to diameter of specimen, the method of capping, and the compressive strength, for the efficient quality control of concrete structures. So this study has been purposed to provide some basic data that can be used effectively at construction sites.

Evaluation of Fracture Toughness and Constraint Effect of Cruciform Specimen under Biaxial Loading (이축하중을 받는 십자형 시편의 파괴인성 및 구속효과 평가)

  • Kim, Jong Min;Kim, Min Chul;Lee, Bong Sang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.62-69
    • /
    • 2016
  • Current guidance considers that uniaxially loaded specimen with a deep crack is used for the determination of the ductile-to-brittle transition temperature. However, reactor pressure vessel is under biaxial loading in real and the existence of deep crack is not probable through periodic in-service-inspection. The elastic stress intensity factor and the elastic-plastic J-integral which were used for crack-tip stress field and fracture mechanics assessment parameters. The difference of the loading condition and crack geometry can significantly influence on these parameters. Thus, a constraint effect caused by differences between standard specimens and a real structure can over/underestimate the fracture toughness, and it affects the results of the structural integrity assessment, consequentially. The present paper investigates the constraint effects by evaluating the master curve $T_0$ reference temperature of PCVN (Pre-cracked Charpy V-Notch) and small scale cruciform specimens which was designed to simulate biaxial loading condition with shallow crack through the fracture toughness tests and 3-dimensional elastic-plastic finite element analyses. Based on the finite element analysis results, the fracture toughness values of a small scale cruciform specimen were estimated, and the geometry-dependent factors of the cruciform specimen considered in the present study were determined. Finally, the transferability of the test results of these specimens was discussed.

Quantitative Assessment of the Fastening Condition and the Crack Size with Using Piezoceramic(PZT) Sensors (압전소자를 이용한 볼트토크 및 크랙의 정량적평가에 관한 연구)

  • Hong, Dong-Pyo;Hong, Yong;Wang, Gao-Ping;Han, Byeong-Hee;Kim, Young-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.603-606
    • /
    • 2006
  • We present a study on the development of a practical and quantitative technique for the assessment of the structural health condition with using piezoceramic(PZT) sensors. The electro-impedance-based technique with the PZT patches is very sensitive for evaluation of the incipient and small damage in a high frequency range, and however the commonly traditional modal analysis method is effective only for considerably larger damages in low frequency range. The paper presents the technique in detecting and characterizing real-time damage on the specimen that is an aluminum plate fastened with bolts and nuts by different torques and as well a plate with a crack. By using the special arrangement of the PZT sensors, the required longitudinal wave is generated through the specimen. A large number of experiments are conducted and the different conditions of the specimens, i.e. the location and extent of loosening bolts, and the plate with a crack are simulated. respectively. Since fixing and loosening the loosened bolt is controlled by a torque wrench, we can control exactly the experiment of the different torques. Compared with the simulated healthy condition, we can find whether or not there is a damage in the specimen with using an impedance analyzer with the PZT sensors. Several indices are discussed and used for assessing the different simulated damages. As for the location of bolt loosening, the RMSD is found to be the most appropriate index for numerical assessment and as well the RMSD shows strongly linear relationship for assessing the extent of the bolt loosening, and the frequency peak shift ${\Delta}F$ is used to assess the cracked plate. The possibility of repeatability of the pristine condition signatures is also presented and the appropriate frequency range and interval are uniquely selected through large numbers of experiments.

  • PDF