• 제목/요약/키워드: specific turbidity

검색결과 62건 처리시간 0.023초

비혼탁도 법을 이용한 나노 콜로이드 입자의 크기 결정 (Determination of Sizes of Nano-Particles by Specific Turbidimetry)

  • 임경희
    • 한국응용과학기술학회지
    • /
    • 제25권1호
    • /
    • pp.107-114
    • /
    • 2008
  • In this article a reliable and rapid method based on specific turbidimetry is proposed for the determination of sizes of nanoparticles. Conventionally in specific turbidimetry specific turbidities for a colloidal dispersion are measured as a function of light wavelength, and compared to theoretical values calculated from Mie scattering theory for presumed particle sizes. In contrast specific turbidity at a fixed wavelength is measured in the proposed method, and particle sizes are determined from the prepared calibration curve. The calibration curve is a plot of specific turbidity vs particle size and in this case the specific turbidities are measured for a couple of samples of known sizes.

평판형 광생물반응기의 미세조류 연속배양을 위한 On-off 제어 (On-off Control for Continuous Culture of Microalgae in Flat Panel Photobioreactor)

  • 김재혁;윤충만;정상화
    • 한국생산제조학회지
    • /
    • 제25권3호
    • /
    • pp.237-243
    • /
    • 2016
  • Recently, technologies that produce biofuels from microalgae are being studied worldwide. It is necessary to significantly reduce the production costs of biofuels from microalgae for economic reasons. In this study, the growth curve of the microalgae was obtained using the batch-culture method, and the specific growth rate was predicted using the regression method. Based on the culture conditions of the estimated specific growth rate, the turbidity of the microalgae in the flat panel photobioreactor (PBR) was measured. Furthermore, an on-off control scheme was applied to the flat panel PBR in order to culture the microalgae continuously on the basis of turbidity. The parameters of the on-off control system were displayed by LabView. The on-off scheme of peristaltic pump was controlled based on the turbidity in the PBR. In addition, the turbidity values of growth curves were compared and analyzed in the continuous culture process using the on-off controller.

Streptococcus mutans에 대한 specific IgY의 항균력 (Antimicrobial activity of Specific IgY against Streptococcus mutans)

  • 김영붕;노정해;손동화;김희주;성기승;이남형
    • 한국식품과학회지
    • /
    • 제32권6호
    • /
    • pp.1319-1325
    • /
    • 2000
  • 본 연구는 면역화된 산란계로부터 생산된 계란 난황중에 들어있는 S. mutans균주의 specific IgY를 분리하여 면역화 여부, Specific IgY 농도별 및 균수별에 따른 항균력을 현미경적 및 탁도측정에 의한 IgY의 항균력 효과를 검토하고자 실시하였다. 면역화 여부에 따른 탁도시험 결과 면역처리된 처리구에 crude IgY를 10%와 20% 첨가에 의해 항균 효과가 있었다. 면역을 하지 않은 닭에서 생산된 계란으로부터 추출한 IgY를 10% 첨가구와 대조구에서는 응집반응을 나타내지 않았다. 그러나 S. mutans로 면역화된 닭에서 생산된 계란에서 추출한 IgY의 10%첨가구는 상등액과 침전물에서는 균들이 응집되는 현상을 보였다. 면역화된 조난황 specific IgY를 첨가한 처리구가 대조구 보다 S. mutans균들이 응집되는 정도에 있어서 확실한 효과를 나타내었다. 조 난황 specific IgY의 농도별 시험에서는 5%이상 첨가구 들에서는 전반적으로 균체들의 응집현상이 나타났으며 IgY를 2.5% 이하로 첨가한 처리구와는 확연한 차이를 보였다. 탁도에 있어서도 조 난황 specific IgY 농도별 시험에서는 첨가농도에 따라 차이가 있었지만 10% 이상 첨가구에서는 탁월한 효과를 나타내었다. 응집된 균괴의 크기는 IgY첨가량이 증가할수록 점점 더 커져가는 현상을 나타내었다. 균수별에서는 $10^5\;cfu/mL$ 이상 접종구에서는 균체들이 응집되는 현상을 보였으며 균수가 많을수록 더욱 응집되는 현상을 나타내었다. Plaque 형성력은 감소하는 경향을 보였으며 IgY 농도 15%에서는 plaque 형성이 약 75%가 저해되었다. 따라서 면역화된 닭으로 부터 생산된 계란에서 추출된 crude IgY를 사용하여 S. mutans균으로부터 발생된 충치를 예방할 수 있을 것으로 사료되었다.

  • PDF

탁도에 따른 음료의 미각 인지: 20, 30대 소비자를 중심으로 (Beverage Taste Perception Influenced by Its Turbidity: Results from Twenties and Thirties)

  • 김태수;최경아;석현정
    • 감성과학
    • /
    • 제20권2호
    • /
    • pp.3-10
    • /
    • 2017
  • 본 연구에서는 음료의 탁도와 맛의 교차-양상에 근거한 연상관계를 탐색하였다. 시각 자극물로 무채색의 막걸리와 탄산음료를 선정하였으며, 자극물은 각각 0.0625~32 g/L, 0.0078~4 g/L 범위 내에서 인지적 등간격을 이룰 수 있도록 열 단계로 나누어 제작하였다. 시각적 관능 평가 실험에서는 '단맛', '짠맛', '쓴맛', '신맛', '마시고 싶은' 기본 미각 형용사와 더불어, 막걸리와 관련된 '누룩향이 나는', '술맛이 나는', '산뜻한' 특징 미각 형용사와 탄산음료와 관련된 '부드러운', '톡 쏘는', '인공적인' 특징 미각 형용사를 선별하여 리커트 3점 척도로 평가하였다(N=35). 실험 결과 기본 미각에 대한 판단에 있어 막걸리는 탁도가 증가함에 따라 기본 맛이 더욱 강하게 느껴지는 반면, 탄산음료의 경우 '신맛'에서만 양의 상관관계가 관찰되었다. 특히 막걸리의 '마시고 싶은' 척도는 4.6~20 g/L 범위에서 가장 높이 관찰됐는데, 이는 시판되는 막걸리 탁도 범위와 일치하여 기억 탁도의 영향을 확인할 수 있었다. 음료 별 미각 형용사에 대해서는 '산뜻한' 맛과 '인공적인' 맛을 제외하고 두 음료 모두 탁도와 강한 양의 상관관계를 보였다. 본 연구의 결과를 바탕으로 음료의 미각적 경험을 공유할 때 탁도를 활용한다면, 각 음료가 추구하는 맛을 보다 효율적으로 소비자에게 전달할 수 있을 것으로 예상된다.

세라믹 정밀여과막 공정을 위한 최적 응집조건 (Optimum Coagulation Conditions for Ceramic Microfiltration Membrane Process)

  • 임재림;이경혁;이영주;박종율
    • 멤브레인
    • /
    • 제22권2호
    • /
    • pp.135-141
    • /
    • 2012
  • 본 연구는 Y 정수장의 세라믹 정밀여과막 공정을 위한 최적의 응집 조건을 도출하고자 수행되었다. 쟈테스트 결과 Y댐 원수의 pH를 7로 조정 시 응집효율이 가장 우수하였으며, 원수 탁도가 10 NTU 이하인 평상시 탁도 조건하에서 최적 응집제 주입량은 3 mg/L (as $Al_2O_3$)인 것으로 나타났다. 최적 응집제를 선정하기 위하여 응집제 종류(PAC, PACS (II), PAHCS)별로 미니모듈 실험장치를 이용하여 평가한 결과 PAC를 주입하고 원수 pH를 7로 조정한 경우 비여과유속 감소율이 가장 낮은 것으로 나타났다. 원수 탁도를 10~150 NTU로 변화시키며 미니모듈에서 비여과유속 감소율을 평가한 결과 원수탁도 10~30 NTU 조건에서는 응집제 주입량 증가에 따라 비여과유속 감소율이 크게 감소하였으나 원수탁도가 50 NTU 이상에서는 응집제 주입량을 증가시켜도 비여과유속 감소율에 큰 차이가 없는 것으로 나타났다. 따라서 Y 정수장을 위해서 는 원수탁도 10 NTU 이하에서는 PAC (11% as $Al_2O_3$) 30 mg/L, 10~50 NTU에서는 30~50 mg/L, 50 NTU 이상에서는 50 mg/L이 적절하다.

입자크기 분포를 고려한 부력침강 저수지 밀도류의 탁도 모델링 (Turbidity Modeling for a Negative Buoyant Density Flow in a Reservoir with Consideration of Multiple Particle Sizes)

  • 정세웅;이흥수;정용락
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.365-377
    • /
    • 2008
  • Large artificial dam reservoirs and associated downstream ecosystems are under increased pressure from long-term negative impacts of turbid flood runoff. Despite various emerging issues of reservoir turbidity flow, turbidity modeling studies have been rare due to lack of experimental data that can support scientific interpretation. Modeling suspended sediment (SS) dynamics, and therefore turbidity ($C_T$), requires provision of constitutive relationships ($SS-C_T$) and accounting for deposition of different SS size fractions/types distribution in order to display this complicated dynamic behavior. This study explored the performance of a coupled two-dimensional (2D) hydrodynamic and particle dynamics model that simulates the fate and transport of a turbid density flow in a negatively buoyant density flow regime. Multiple groups of suspended sediment (SS), classified by the particle size and their site-specific $SS-C_T$ relationships, were used for the conversion between field measurements ($C_T$) and model state variables (SS). The 2D model showed, in overall, good performance in reproducing the reservoir thermal structure, flood propagation dynamics and the magnitude and distribution of turbidity in the stratified reservoir. Some significant errors were noticed in the transitional zone due to the inherent lateral averaging assumption of the 2D hydrodynamic model, and in the lacustrine zone possibly due to long-term decay of particulate organic matters induced during flood runoffs.

홍수시 대청호 유역에 발생하는 탁수의 물리적 특성 (Characterization of Physical Properties of Turbid Flow in the Daecheong Reservoir Watershed dining Floods)

  • 정세웅;이흥수;윤성완;예령;이준호;추창오
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.934-944
    • /
    • 2007
  • Fine suspended solids (SS) induced into a reservoir after flood events play important ecological and water quality roles by presenting persistent turbidity and attenuating light. Thus the origin and physical features must be characterized to understand their transport processes and associated impacts, and for the establishment of watershed based prevention strategies. This study was aimed to characterize the physical properties of the SS sampled from Daecheong Reservoir and its upstream rivers during flood events. Extensive field and laboratory experiments were carried out to identify the turbidity-SS relationships, particle size distributions, settling velocity, and mineral compositions of the SS. Results showed that the turbidity-SS relationships are site-specific depending on the locations and flood events in the system. The turbidity measured within the reservoir was much greater than that measured in the upstream rivers for the same SS value. The effective diameters ($D_{50}$) in the rivers were in the range of $13.3{\sim}54.3{\mu}m$, while those in the reservoir were reduced to $2.5{\sim}14.0{\mu}m$ due to a fast settling of large particles in the rivers. The major minerals consisting of the SS were found to be Illite, Muscovite, Albite, and Quartz both in the rivers and reservoir. Their apparent settling velocities at various locations in the reservoir were in the range of 0.06~0.13 m/day. The research outcome provides a fundamental information for the fine suspended particles that cause persistent turbidity in the reservoir, and can be used as basic parameters for modeling study to search watershed based optimal control measures.

탁수모델링에 사용하는 유량-SS 관계의 불확실성 (Uncertainty of Discharge-SS Relationship Used for Turbid Flow Modeling)

  • 정세웅;이정현;이흥수;맹승진
    • 한국수자원학회논문집
    • /
    • 제44권12호
    • /
    • pp.991-1000
    • /
    • 2011
  • 저수지 탁수 모델링에서 실측자료가 없는 경우 유입하천 부유사 농도(SS) 산정을 위해 유량(Q)과 SS 관계식이 자주 사용된다. 일반적으로 하천을 통과하는 SS 부하율은 유량에 의해 변동된다는 가정 하에 유량과 SS의 멱함수(SS=aQb) 관계가 가장 빈번히 적용되고 있다. 그러나 Q-SS 관계는 측정 지점에 따라 배타적 특성을 가지며, 동일 지점에 대해서도 연중 계절적 변동성이 있다. 더욱이, Q-SS 관계는 동일한 수문곡선에서도 유량 상승기와 하강기에 이격현상을 보이기도 한다. 본 연구의 목적은 용담댐 저수지와 소양강댐 저수지 유입 하천에서 강우시 연속 실측한 자료를 바탕으로 Q-SS 관계의 이격현상을 고찰하고, SS 부하율 산정 오차에 미치는 영향을 분석하는데 있다. 연구결과, Q-SS 관계는 홍수사상 동안 높은 분산도와 시계방향의 이격현상을 보였으며, 동일한 유량에 대해 유량 상승기가 하강기보다 SS 농도가 높게 나타났다. 이러한 이격현상은 저수지로 유입하는 SS 부하량 산정에 있어 유의할 만한 오차로 작용하였으며 Q-SS 멱함수는 실측 부하량을 과소평가하는 결과를 가져왔다. 이것은 저수지 탁수모델링에서 중요하게 고려해야 할 사항이다. 본 연구에서는 Q-SS 관계식의 대안으로 탁도-SS관계가 제시되었다. 탁도-SS 관계는Q-SS 관계보다 분산도가 작았으며 실측 부하량과의 오차를 획기적으로 줄였다. 따라서 저수지로 유입하는 SS 부하율의 보다 정확한 산정과 탁수모델링의 신뢰도를 높이기 위해서는 유입 탁도에 대한 실시간모니터링이 필요하다.

한외여과를 이용한 폐 CMP Slurry의 분리에서 압력의 영향 (Pressure Effect on Ultrafiltration of Used CMP Slurry)

  • 홍성호
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.486-492
    • /
    • 2004
  • CMP (Chemical mechanical polishing) is inevitable process to overcome $0.2{\mu}m$ wire thickness in semiconductor industry. In this study, effect of pressure to separate used CMP slurry into solid and liquid for recycle and reuse by ultrafiltration was investigated. Also, water quality after the ultrafiltration such as turbidity and TDS was evaluated. The material of membrane used in the study was PVDF. The used CMP contained 0.5% of solid content and then concentrated up to 18% by weight. The used CMP can not be concentrated higher than 18% because of viscosity and abrasion of pump. The tested feed pressures were 22.1, 29.4 and 36.8 psi. The results have shown that operating at 36.8 psi has advantages on operation time and total flux. The specific flux showed some variation at 1 to 15 of concentration factor but no difference after 15 of concentration factor. Mass balance of solid at initial stage of the operation showed some unbalance because of deposition of solid on the membrane, which was main reason to reduce flux. Turbidity was very stable at lower than 0.2NTU for 22.1 and 36.8 psi of feed pressure.

병렬구조 TSK 퍼지 모델을 이용한 선박용 기름배출 감시장치의 실시간 기름농도 예측모델 (On-line Prediction Model of Oil Content in Oil Discharge Monitoring Equipment Using Parallel TSK Fuzzy Modeling)

  • 백경동;조재우;최문호;김성신
    • 제어로봇시스템학회논문지
    • /
    • 제16권1호
    • /
    • pp.12-17
    • /
    • 2010
  • The oil tanker ship over 150GRT must equip oil content meter which satisfy requirements of revised MARPOL 73/78. Online measurement of oil content in complex samples is required to have fast response, continuous measurement, and satisfaction of ${\pm}10ppm$ or ${\pm}10%$ error in this field. The research of this paper is to develop oil content measurement system using analysis of light transmission and scattering among turbidity measurement methods. Light transmission and scattering are analytical methods commonly used in instrumentation for online turbidity measurement of oil in water. Gasoline is experimented as a sample and the oil content approximately ranged from 14ppm to 600ppm. TSK Fuzzy Model may be suitable to associate variously derived spectral signals with specific content of oil having various interfering factors. Proposed Parallel TSK Fuzzy Model is reasonably used to classify oil content in comparison with other models. Those measurement methods would be effectively applied and commercialized to oil content meter that is key components of oil discharge monitoring control equipment.