• Title/Summary/Keyword: specific discharge

검색결과 608건 처리시간 0.03초

비열플라즈마에 의한 수소가스발생에 미치는 수표면 진통효과 (The effect of vibration of the water surface for hydrogen gas generation by plasma electrical discharge)

  • 김종석;박재윤;정장근;김태용;이재동;고희석;이현우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.115-119
    • /
    • 2004
  • This paper is investigated about the effect of vibration of the water surface for hydrogen gas generation by non-thermal plasma. The vibration of the water surface is more powerful with increasing applied voltage. In this experimental reactor which is made of multi-needle and plate, the maximum acquired hydrogen production rate is about 6.8[ml/sec]. Although the generation of hydrogen gas is increased with elevating time, it is saturated after specific time due to the volume of reactor and the saturation of taylor cone.

  • PDF

LiNiO$_2$/Li cell의 전기화학적 특성 (Electrochemical Properties of LiNiO$_2$/Li cell)

  • 전대규;김철중;성창호;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 1997
  • The propose of this study is research and improvement of LiNiO$_2$as cathode material for Lithium secondary batteries. LiNiO$_2$is prepared by heating LiOH . $H_2O$ and Ni(OH)$_2$(mole ratio 1 : 1) on various heat condition. In the result of XRD mesurement, all LiNiO$_2$prepared at this study showed hexagonal structure. In Cyclic Voltammetry, LiNiO$_2$is not conspicous about oxidation peak but oxidation curve change steeply over 3.8V and reduction peak discover at 3.6V. In discharge capacities, specific capacity is higher $O_2$than air when preliminary heated and 75$0^{\circ}C$ than $700^{\circ}C$, 80$0^{\circ}C$ when heated. Therefore, when preliminary heat at $650^{\circ}C$ $O_2$and heat at 75$0^{\circ}C$ carried out, discharge property is the best.

  • PDF

타 의료기관으로 이탈한 암환자의 특성 파악 (The Identification of the Characteristics of Cancer Patients Who Defected to Other Medical Institutions)

  • 차재빈;남정혜;안성식
    • 보건의료산업학회지
    • /
    • 제7권1호
    • /
    • pp.1-9
    • /
    • 2013
  • This study intends to identify the characteristics of cancer in-patients and those of cancer patients who defected to other medical institutions based on the summary of hospital discharge information of a university hospital for the purpose of improving work efficiency and maximizing the number of patients. The study used data on cancer patients registered in the database of C University Hospital in Gyeonggi Province for a period of one year between January 1 and December 31. The analysis results suggest that the commonalities of the cancer patients who defected to other medical institutions include no specific job, old age, and hospitalization through emergency room. In conclusion, hospitals need to identify the characteristics of cancer patients classified as patients who are prone to defect and the defection factors through this prediction model.

문산천의 유사특성 및 장기하상변동 예측 (Sediment Properties and Long-term Bed Change of Munsancheon)

  • 이재근;안재현
    • 한국습지학회지
    • /
    • 제13권2호
    • /
    • pp.329-341
    • /
    • 2011
  • 본 연구는 경기도 파주시에 위치한 문산천의 유사량을 직접 실측하여 유사특성을 분석하고, 이를 수치모형에 적용하여 장기적인 하상변동을 예측하였다. 직접 실측된 유사랑을 이용하여 유량-총유사량 관계식을 유도하였으며, 기존의 추정공식을 통해 산정된 총유사량과의 비교를 통해 적절한 유사량 추정방법을 평가하였다. 실측에 의한 문산천의 연간 총유사량은 5,478ton/year, 비유사량은 29.23ton/$km^2$/year로 나타났으며, 기존의 공식과 비교한 결과 Ackers & White공식이 실측치와 매우 유사한 값을 산정하였다. 실측된 유사량 및 지형, 수문자료를 입력변수로 하여 HEC-6와 GSTARS 모형을 비교, 평가하였다. 이를 통해 HEC-6 모형이 문산천의 장기하상변동 예측에 적합한 모형으로 신뢰할 수 있는 결과를 도출할 수 있다고 판단하였으며, 본 연구의 장기하상변동 예측에 적용하였다. HEC-6 모형을 이용한 장기하상변동 예측결과 문산천의 경우 하류부에서는 지속적으로 퇴적이 나타나고 상류부에서는 전반적으로 침식이 발생하였으며, 향후 20년 후의 하상상태로 안정화 될 것으로 판단되었다. 하상 변동량은 20년동안 1m 이내로 유의한 수준에 있다. 그러나 감조부의 영향을 받는 하류부에서는 유출구로부터 2,000m~7,000m 사이의 구간에 퇴적이 지속적으로 증가하고 있어 향후 하천관리계획 수립시 고려해야 할 것으로 판단되었다.

리튬이온전지용 $LiCoO_2$정극의 도전재료에 따른 초기 충방전 특성 (Initial Charge/Discharge of $LiCoO_2$ Composite Cathode with Various Content of Conductive Material for the Lithium ion Battery)

  • 도칠훈;문성인;윤문수;박천준;염덕형;윤성규
    • 전기화학회지
    • /
    • 제2권3호
    • /
    • pp.123-129
    • /
    • 1999
  • 리튬이온전지용 $LiCoO_2$ 전극의 super s black 도전재료의 함량에 따른 초기 충방전 특성을 1 mol/l $LiPF_6/EC+DEC(1:3\;by\;w/w)$의 전해액에서 리튬기준전극에 대하여 4.3 V에서 2.0 V의 전위 구간에 대하여 C/4 및 C/2율로 충방전하여 측정하였다. 최초의 충전과정에서 high impedance충전 특성을 보였으며, super s black도전재료를 $3\%w/w$ 사용한 경우, $0.5 mA/cm^2$ 전류밀도의 충전에서 high impedance의 해소에 따라 $3.82\;{\Omega}\;{\cdot}\;g-LiCoCo_2$의 저항 감소를 나타내었으며, $0.728\;{\Omega}{\cdot}g-LiCoCo_2$의 전극저항과 비교하여 약 7배 높은 값을 나타내었다. 제2차 충전에의 high impedance해소는 약 $63\;{\Omega}{\cdot}g-LiCoCo_2$으로서 전극저항의 $12\%$ 정도이며, 제1차 충전의 high impedance해소에 비하여 $1.7\%$의 수준으로 감소하였다. 제1차 충전 및 방전 비용량은 C/4방전율에서 각각 160-161 및 $153\~155mAh/g-LiCoO_2$으로, 쿨롱효율은 $95.4\~96.4\%$였으며, 비가역 비용량은 약 6 mAh/g-$LiCoO_2$였다. 충전종료 지점에서 측정한 비저항은 도전재료 함량 $2\~7\%w/w$범위에서 낮은 값을 나타내어 비가역 비용량 특성의 변화와 일치하였다. 도전재료의 함량 증가에 따라 용량밀도가 감소하였으며, C/4율 방전에서 super s black함량 $2\%w/w$$2.9\%w/w$의 도전재료를 사용한 전극의 용량밀도는 각각 447mAh/ml 및 431 mAh/ml였다

수문운영에 따른 낙단보 상류하도 흐름특성 해석 (Analysis of Flow Characteristics in Upstream Channel depending on Water Gate Operation of Nakdan Multi Functional Weir)

  • 문상철;박기범;안승섭
    • 한국환경과학회지
    • /
    • 제25권4호
    • /
    • pp.491-504
    • /
    • 2016
  • This study, examines the flow characteristics of upstream channel depending on water gate operation of Nakdan Multi-fuctional weir. The specific purpose of this study are to simulate the variation of flow velocity depending on the operation of the weir using 1-dimensional hydraulic model, HEC-RAS, and compare it with observed velocity. For discharge conditions from $50m^3/s$ to $3,500m^3/s$, it is observed that the velocity of upstream channel is almost constant, whereas for probability flood discharge, the velocity and froude number are increased as the discharge values are increased. The velocity values for downstream boundary condition EL, 40.0 m are more decreased than those for EL. 40.5m. From comparison on the variation of water stage depending on water gate operation, it is observed that the stage values are almost constant for discharges below $300m^3/s$, whereas 5 cm to 20 cm for discharges over $700m^3/s$. Flow velocity at streamflow gauging station. Nakdong, is decreased by more than 875% after installing the weir. The results obtained from this study indicate that the velocity of upstream channel is decreased and the discharge and velocity of downstream channel are significantly varied after installing the weir.

Electrochemical double layer capacitors with PEO and Sri Lankan natural graphite

  • Jayamaha, Bandara;Dissanayake, Malavi A.K.L.;Vignarooban, Kandasamy;Vidanapathirana, Kamal P.;Perera, Kumudu S.
    • Advances in Energy Research
    • /
    • 제5권3호
    • /
    • pp.219-226
    • /
    • 2017
  • Electrochemical double layer capacitors (EDLCs) have received a tremendous interest due to their suitability for diverse applications. They have been fabricated using different carbon based electrodes including activated carbons, single walled/multi walled carbon nano tubes. But, graphite which is one of the natural resources in Sri Lanka has not been given a considerable attention towards using for EDLCs though it is a famous carbon material. On the other hand, EDLCs are well reported with various liquid electrolytes which are associated with numerous drawbacks. Gel polymer electrolytes (GPE) are well known alternative for liquid electrolytes. In this paper, it is reported about an EDLC fabricated with a nano composite polyethylene oxide based GPE and two Sri Lankan graphite based electrodes. The composition of the GPE was [{(10PEO: $NaClO_4$) molar ratio}: 75wt.% PC] : 5 wt.% $TiO_2$. GPE was prepared using the solvent casting method. Two graphite electrodes were prepared by mixing 85% graphite and 15% polyvinylidenefluoride (PVdF) in acetone and casting n fluorine doped tin oxide glass plates. GPE film was sandwiched in between the two graphite electrodes. A non faradaic charge discharge mechanism was observed from the Cyclic Voltammetry study. GPE was stable in the potential windows from (-0.8 V-0.8 V) to (-1.5 V-1.5 V). By increasing the width of the potential window, single electrode specific capacity increased. Impedance plots confirmed the capacitive behavior at low frequency region. Galvanostatic charge discharge test yielded an average discharge capacity of $0.60Fg^{-1}$.

액체산소/케로신 가스발생기 사이클 액체로켓엔진 터빈 노즐목 면적 변화 추정 방법 (Estimation Methods for Turbine Nozzle Throat Area Reduction of A LOx/Kerosene Gas Generator Cycle Liquid Propellant Rocket Engine)

  • 남창호;문윤완;박순영;김진한
    • 한국추진공학회지
    • /
    • 제23권5호
    • /
    • pp.101-106
    • /
    • 2019
  • 액체산소/케로신 가스발생기 사이클 엔진의 터빈 노즐목 수트(soot) 침착 특성을 파악하기 위한 변수를 정의하고 한국형발사체 1단 엔진 시험결과에 적용하였다. 터빈 가스의 물성치를 이용한 노즐목의 분출 계수 정의를 하는 방법이 있고 터빈 노즐목 전단과 터빈 배기 노즐목 전단의 압력비와 온도비를 이용하여 분출계수를 정의할 수 있다. 한국형발사체 1단 엔진 시험 결과를 분석한 결과 터빈 노즐목의 분출계수(discharge coefficient)는 시간에 따라 감소하며 동일 엔진에 대한 누적 연소시간에 대해서도 감소하는 경향을 보인다. 누적 시험 초기에는 터빈 노즐목 감소가 그 다음 시험과 연계되지만 일정 시간 이후에는 일정 범위에서 등락을 거듭하는 듯한 특성을 보인다.

Hospital-Acquired Pressure Injury: Clinical Characteristics and Outcomes in Critical Care

  • Hyun, Sookyung;Moffatt-Bruce, Susan;Newton, Cheryl;Hixon, Brenda
    • International Journal of Advanced Culture Technology
    • /
    • 제7권2호
    • /
    • pp.28-33
    • /
    • 2019
  • Electronic health records (EHRs) enable us to use and re-use electronic data for various multiple purposes, such as public reporting, quality improvement, and patient outcomes research. Current hospital-acquired pressure injury (HAPI) risk assessment instruments have not been specifically developed for intensive care unit (ICU) patients and showed false positive rates in this specific populations. Previous research studies report a number of risk factors; however, it is still not clear what factors influence ICU HAPI in this population. As part of a larger research study, we performed an exploratory analysis by using a large electronic health record data. The aims of this study were to compare characteristics of patients who developed HAPIs during their ICU stay with those who did not, and to determine whether the two groups were different in the aspects of length of ICU stay, discharge disposition, and discharge destinations. We conducted chi-square test and t-test for group comparison. Association was examined by using bivariate analyses. Pearson correlation coefficients were used to examine correlation between LOS and number of medications. Our findings suggest a number of consistent and potentially modifiable risk factors, such as sedation, feeding tubes, and the number of medications administered. The mortality of the HAPI group was significantly higher than the non-HAPI group in our data. Discharge disposition was significantly different between the groups. 67% of the HAPI group transferred to intermediate or long-term care hospitals whereas 57.7% of the non-HAPI group went home after discharge. Awareness of these risk factors can lead to clinical interventions that can be preventative in the ICU setting.

하이드로폰을 이용한 산림유역 소류사 유출량 산정 및 현장 적용성 검토 (Evaluation of Field Application and Estimation of Bedload Discharge in the Forest Watershed using the Hydrophone)

  • 서준표;김기대;우충식;이창우;이헌호
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.807-818
    • /
    • 2020
  • 본 연구에서는 산림유역의 소류사 유출량을 산정하기 위해 음향센서를 이용한 하이드로폰을 사용하였다. 하이드로폰의 수로실험과 현장실험을 통해 반응 특성을 분석하고 정량적 소류사 유출량을 산정하여 실측된 유출량과 비교·분석하였다. 하이드로폰 반응은 유량 변화에 따라 펄스값이 변하였지만 모래에는 반응하지 않았다. 입자 크기와 무게에 따라서 펄스값이 다르게 나타났는데 크기와 무게에 따라 적합한 반응을 나타내는 특정 채널이 있었다. 또한 무게와 부피 변화에 따른 반응도 적합하게 나타났지만 특히, 무게 추정에 적절한 것으로 분석되었다. 현장에 설치된 하이드로폰에 대해서 자동충격전달 장치를 이용하여 채널별 반응 특성 분석으로 센서의 정상작동 여부 및 채널별 출력값의 적합성을 확인하고 소류사 유출량 산정을 위해 적합한 채널을 선정하였다. 하이드로폰 펄스와 평균유량을 이용하여 소류사 유출량 산정식을 개발하고 개발된 식과 현장에 실측된 유출량과 비교한 결과 전체적으로 실측값과 유사하게 나타났다. 하이드로폰을 산림유역의 소류사 모니터링에 활용한다면 유출되는 소류사량의 무게를 정량적이고 지속적으로 산정하는데 효율적인 것으로 검토되었다. 국내 산림유역에서 음향센서가 내장된 하이드로폰을 이용하여 소류사 등 토사유출 모니터링에 활용성을 검증함으로써 관련 분야의 연구 및 기술개발 증진에 도움이 될 것으로 기대된다.