• Title/Summary/Keyword: speciation analysis

검색결과 92건 처리시간 0.058초

오염원에 따른 토양 입경 별 비소의 오염특성 및 생물학적 접근성 평가 (Effects of Contamination Source and Particle Size on Arsenic Speciation and Bioaccessibility in Soils)

  • 권예슬;김은정
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.89-97
    • /
    • 2017
  • In this study, we evaluated effect of particle size on arsenic solid-state speciation and bioaccessibility in soils highly contaminated with arsenic from smelting and mining. Soils were partitioned into six particle size fractions ($2000-500{\mu}m$, $500-250{\mu}m$, $250-150{\mu}m$, $150-75{\mu}m$, $75-38{\mu}m$, <$38{\mu}m$), and arsenic solid-state speciation and bioaccessibility were characterized in each particle size fraction. Arsenic solid-state speciation was characterized via sequential extraction and XRD analysis, and arsenic bioaccessibility was evaluated by SBRC (Solubility Bioaccessibility Research Consortium) method. In smelter site soil, arsenic was mainly present as arsenic bound to amorphous iron oxides. Fine particle size fractions showed higher arsenic concentration, but lower arsenic bioaccessibility. On the other hand, arsenic in mine site soil showed highest concentration in largest particle size fraction ($2000-500{\mu}m$), while higher bioaccessibility was observed in smaller particle size fractions. Arsenic in mine site soil was mainly present as arsenolite ($As_2O_3$) phase, which seemed to affect the distribution of arsenic and arsenic bioaccessibility in different particle size fractions of the mine soil.

Chemical Speciation of Trace Metals in Natural Water by Ultrafiltration/Size Exclusion Chromatography/UV Absorption/ICP-MS

  • Haraguchi, Hiroki;Itoh, Akihide;Kimata, Chisen
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.405-410
    • /
    • 1995
  • A study on elemental speciation of trace metals in lake water (Lake Biwa in Japan) has been carried out by a size exclusion chromatography (SEC) / inductively coupled plasma mass spectrometry (ICP-MS) system. Before analysis, the water sample was preconcentrated with a ultrafiltration technique, where the large molecules with molecular weight larger than 10,000 were concentrated. Then the preconcentrated water samples (500-1000 fold) were analyzed by a SEC/ICP-MS system. Most trace metals were found at the UV absorption peaks corresponding to the molecular weights of ca. 300,000 and 10,000-50,000, where trace metals were on-line detected by ICP-MS. The results suggest that many of trace metals exist as the large organic molecules-metal complexes in natural water.

  • PDF

수중의 비소 종 분리 분석 (Speciation Analysis of Arsenic Species in Surface Water)

  • 정관조;김덕찬
    • 대한환경공학회지
    • /
    • 제30권6호
    • /
    • pp.621-627
    • /
    • 2008
  • 본 연구에서는 물속 As(III)와 As(V)의 종 규명분석에 필요한 HPLC와 DRC-ICP-MS의 최적조건을 설정하고, 이를 이용하여 한강 팔당수계 10개 지류 천으로부터 채취한 시료중의 As(III)와 As(V)를 분석 검토하였다. 종 분리를 위한 HPLC의 이동상으로는 10 mM ammonium nitrate와 10 mM ammonium phosphate monobasic을 사용하였으며, flushing solvent로는 5% v/v 메탄올을 사용하였다. 검출기는 DRC-ICP-MS를, 반응기체는 산소를 사용하였다. 최적 분석조건을 설정하기 위하여 이동상의 pH, 유량 및 시료 주입량과 DRC의 산소 유량을 달리하여 검토한 결과, 이동상의 pH는 9.4, 유량은 1.5 mL/min, 시료 주입량은 100 $\mu$L, 산소의 유량은 0.5 mL/min이었을 때 가장 좋은 분석조건으로 나타났다. 검정곡선은 As(III)와 As(V)에 대해 모두 r$^2$ = 0.998 이상의 선형성을 나타냈으며, As(III)의 검출한계는 0.10 $\mu$g/L, 정확도(RSD)는 4.3%, 회수율은 95.2%, As(V)의 검출한계는 0.08 $\mu$g/L, 정확도(RSD)는 3.6%, 회수율은 96.4%로 나타났다. 분석시간은 4분이었다. 설정된 파라미터를 적용하여 한강 팔당수계 유입 10개 지류 천에서 채수한 시료를 분석한 결과, As(III)는 0.10$\sim$0.22 $\mu$g/L, As(V)는 0.44$\sim$1.19 $\mu$g/L의 범위로 나타났으며, 총 비소의 93.5%가 As(V)의 형태인 것을 확인할 수 있었다.

Tritium and 14C in the Environment and Nuclear Facilities: Sources and Analytical Methods

  • Hou, Xiaolin
    • 방사성폐기물학회지
    • /
    • 제16권1호
    • /
    • pp.11-39
    • /
    • 2018
  • Tritium and $^{14}C$ are two most important radionuclides released from nuclear facilities to the environment, and $^{14}C$ contributes dominant radiation dose to the population around nuclear power plants. This paper presents an overview of the production, pathway, species and levels of tritium and $^{14}C$ in nuclear facilities, mainly nuclear power plants. The methods for sampling and collection of different species of tritium and $^{14}C$ in the discharge gas from the stack in the nuclear facilities, atmosphere of the nuclear facilities and environment are presented, and the features of different methods are reviewed. The on-line monitoring methods of gaseous tritium and $^{14}C$ in air and laboratory measurement methods for sensitive determination of tritium and $^{14}C$ in collected samples, water and environmental solid samples are also discussed in detailed. Meanwhile, the challenges in the determination and speciation analysis of tritium and $^{14}C$ are also highlighted.

염화페놀류 화합물의 HDTMA-montmorillonite에 대한 수착 동력학에 미치는 ph의 영향 (Effect of pH on the sorption kinetics of chlorophenols onto HDTMA-montmorillonite)

  • Mun Yong, Gwak;Dong Ik, Song
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.186-191
    • /
    • 2004
  • Sorption kinetics of 2-chlorophenol(2-ChP), 2,4-dichlorophenol(2,4-DChP) and 2,4,5-trichlorophenol (2,4,5-TChP), onto montmorillonite modified with hexadecyltrimethyl ammonium cations(HDTMA-mont) were investigated. One-site mass transfer model(OSMTM) and two compartment first-order kinetic model(TCFOKM) were used to analyze kinetics. As expected from the number of model parameters involved, the three-parameter TCFOKM was better than the two-parameter OSMTM in describing sorption and desorption kinetics of chlorophenols in HDTMA-mont. For all chlorophenols, the results of OSMTM analysis indicate that the predominant deprotonated speciation(at pH 9.15) exhibited higher mass transfer coefficient( $k_{s}$ ) than the protonated speciation(at pH 4.85). This is because the deprotonated speciation has stronger hydrophobic interaction than protonated speciation. Most sorption completes in three hours. The fraction of the fast sorption and the first-order sorption rate constants for the fast and slow compartments in TCFOKM were determined by fitting experimental data to the TCFOKM. The results of kinetics reveal that the fraction of the fast sorption( $f_1$) and the sorption rate constants in the fast compartments( $k_1$) were in the order 2,4,5-TChP > 2,4-DChP > 2-ChP, which agrees with the magnitude of the $K_{ow}$ . The first-order sorption rate constants in the fast compartment(10$^{0.8}$ - 10$^{1.22}$ h $r^{-1}$ ) were much larger than those in the slow compartment(10$^{-1}$.74/ - 10$^{-2}$.622/ h $r^{-1}$ ).> ).).

  • PDF

SMOKE 모델의 입력 모듈 변경에 따른 영향 분석 (Assessment of Changed Input Modules with SMOKE Model)

  • 김지영;김정수;홍지형;정동일;반수진;이용미
    • 한국대기환경학회지
    • /
    • 제24권3호
    • /
    • pp.284-299
    • /
    • 2008
  • Emission input modules was developed to produce emission input data and change some profiles for Sparse Matrix Operator Kernel Emissions (SMOKE) using Clean Air Policy Support System (CAPSS)'s activities and previous studies. Specially, this study was focused to improve chemical speciation and temporal allocation profiles of SMOKE. At first, SCC cord mapping was done. 579 SCC cords of CAPSS were matched with EPA's one. Temporal allocation profiles were changed using CAPSS monthly activities. And Chemical speciation profiles were substituted using Kang et al. (2000) and Lee et al. (2005) studies and Kim et al. (2005) study. Simulation in Seoul Metropolitan Area (Seoul, Incheon, Gyeonggi) using MM5, SMOKE and CMAQ modeling system was done for effect analysis of changed input modules of SMOKE. Emission model results adjusted with new input modules were slightly changed as compared to using EPA's default modules. SMOKE outputs shows that aldehyde emissions were decreased 4.78% after changing chemical profiles, increased 0.85% after implementing new temporal profiles. Toluene emissions were decreased 18.56% by changing chemical speciation profiles, increased 0.67% by replacing temporal profiles as well. Simulated results of air quality were also slightly elevated by using new input modules. Continuous accumulation of domestic data and studies to develop input system for air quality modeling would produce more improved results of air quality prediction.