• Title/Summary/Keyword: span/depth ratio

Search Result 296, Processing Time 0.024 seconds

Shear Strength of High Strength Concrete Beams with Steel Fibrous (강섬유를 혼입한 고강도 콘크리트 보의 전단강도)

  • 곽계환;박종건;정태영
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.23-30
    • /
    • 2000
  • The purpose of this paper is to study on the shear strength of high strength concrete beams with steel fibrous. In general, the shear strength of reinforced concrete beams is affected by the compressive strengths of concrete( c), the shear span-depth ratio(a/d), the longitudinal steel ratio($\rho$ $\omega$), and shear reinforcement. An experimental investigation of the shear strength of high strength concrete beams with steel fibrous was conducted. In each series the shear span-depth ratio(a/d) was held constant at 1.5, 2.8, or 3.6, while concrete strengths were varied from 320 to 520, to 800kgf/$\textrm{cm}^2$. To verify the proposed equations the experimental results were compared with those from other researches such as equation of ACI code 318-95 or equation of Zsutty. To deduce equation for shear strength from experimental data carried out MINITAP program. According to the experimental results, the addition of steel fibrous has increased the deflection and strain at failure load, improving the brittleness of the high strength concrete.

Analysis of Prestressed Concrete Continuous Members with Unbonded Tendons (부착되지 않은 텐돈을 갖는 PS 콘크리트 연속부재의 해석적 연구)

  • 문정호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.197-208
    • /
    • 1995
  • The prestressed concrete continuous members with unbonded tendons were investigated while comparing the experimental data with the analytical results. The comparison was carried out with the program TAPS which can take into account the unbonded tendon effects. The subjects that were interested included the load-deflection response, the design equations for the tendon stress at failure, the effects of bonded reinforcements, the effects of span-depth ratio, the effects of loading type. In this paper, contiriuous prestressed concrete members with unbonded ten dons were investigated. Of twelve tests with continuous members, six were two-span beams and six were three span one-way slats. Analytical results were compared favorably with experimental data and disclosed that the tendon stress at flexural failure is the function of the amount of bonded reinforcements, the loading types and patterns, and the tendon profile.

Strut-Tie Models and Load Distribution Ratios for Reinforced Concrete Beams with Shear Span-to-Effective Depth Ratio of Less than 3 (I) Models and Load Distribution Ratios (전단경간비가 3 이하인 철근콘크리트 보의 스트럿-타이 모델 및 하중분배율(I) 모델 및 하중분배율)

  • Chae, Hyun-Soo;Yun, Young Mook
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.257-265
    • /
    • 2016
  • The failure behavior of reinforced concrete beams is governed by the mechanical relationships between the shear span-to-effective depth ratio, flexural reinforcement ratio, load and support conditions, and material properties. In this study, two simple indeterminate strut-tie models which can reflect all characteristics of the failure behavior of reinforced concrete beams were proposed. The proposed models are effective for the beams with shear span-to-effective depth ratio of less than 3. For each model, a load distribution ratio, defined as the fraction of load transferred by a truss mechanism, is also proposed to help structural designers perform the rational design of the beams by using the strut-tie model approaches of current design codes. In the determination of the load distribution ratios, the effect of the primary design variables including shear span-to-effective depth ratio, flexural reinforcement ratio, and compressive strength of concrete was reflected through numerous material nonlinear analysis of the proposed indeterminate strut-tie models. In the companion paper, the validity of the proposed models and load distribution ratios was examined by applying them to the evaluation of the failure strength of 335 reinforced concrete beams tested to failure by others.

Strut-Tie Models and Load Distribution Ratios for Reinforced Concrete Beams with Shear Span-to-Effective Depth Ratio of Less than 3 (II) Validity Evaluation (전단경간비가 3 이하인 철근콘크리트 보의 스트럿-타이 모델 및 하중분배율(II) 타당성 평가)

  • Chae, Hyun-Soo;Yun, Young Mook
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.267-278
    • /
    • 2016
  • In this study, the ultimate strength of 335 simply supported reinforced concrete beams with shear span-to-effective depth ratio of less than 3 was evaluated by the ACI 318-14's strut-tie model approach implemented with the indeterminate strut-tie models and load distribution ratios of the companion paper. The ultimate strength of the beams was also estimated by using the experimental shear strength models, the theoretical shear strength models, and the current strut-tie model design codes. The validity of the proposed strut-tie models and load distribution ratios was examined by comparing the strength analysis results classified according to the prime design variables of the shear span-to-effective depth ratio, flexural reinforcement ratio, and compressive strength of concrete.

Failure Behavior of FRP RC Beams without Shear Reinforcements (전단 보강이 없는 FRP RC보의 파괴 거동)

  • Lee, Jae-Hoon;Son, Hyun-A;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • In order to substitute FRP bar for steel bar in new structures, it is necessary to establish a reliable design code. But relatively little research has been conducted on the material in Korea. So, a total of 22 beam specimens (18 GFRP reinforced concrete and 4 conventional steel reinforced concrete) were constructed and tested. In the first phase of the experiment, it was carried out to observe flexural behavior, and collect deflection and crack data. In order to eliminate of the uncertainty by the shear reinforcements and induce flexural failure mode, any stirrup were not used and only shear span-depth ratio were adjusted. However, almost beams were broken by shear and the ACI 440.1R, CSA S806, which were used to design test beams, showed considerable deviation between prediction and test results of shear strengths. Therefore in the second phase of the study, shear failure modes and behavior were observed. A standard specimen had dimensions of 3,300 mm long ${\times}$ 800 mm wide ${\times}$ 200 mm effective depth. Clear span and shear span were 2,800 mm, 1,200 mm respectively. Control shear span-depth ratio was 6.0. Four-point bending test over simple support was conducted. Variables of the specimens were concrete compressive strength, type and elastic modulus of reinforcement, shear span-depth ratio, effective reinforcement ratio, the effect of bundle placing method and cover thickness.

Design Comparison of Strut Tie Model and ACI Traditional by Clear Span-to-Depth Ratio (지간-높이 비에 따른 스트럿-타이 모델과 ACI 고전적인 방법의 설계 비교)

  • Lymei, Uy;Son, Byung-Jik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2406-2413
    • /
    • 2014
  • Since clear span-to-depth ratio is used to define what is so called a deep beam, it is an important parameter ratio for study about deep beam. Deep beams can be designed by flexure design method, and shear provided by concrete ($v_c$) and by steel ($v_s$) for deep flexure members are provided in ACI 318-99 [1]. But in later version of ACI (from ACI 318-02) it is not provided and deep beams shall be designed either by taking into account nonlinear distribution of strain or by Appendix A of Strut-and-Tie Models (STM). The trend of deep beam design seems to be familiar with strut-and-tie model, but ACI traditional design is not forgotten. By comparing these two method, there should a point which definitely explain the different between the two methods. In this study, 68 samples result of steel, after reinforcement arrangement, are taken to be analyzed.

Experimental Study on Shear Strength of Concrete Deep Beam Reinforced FRP Bars (FRP Bar로 보강된 콘크리트 깊은보의 전단강도에 관한 실험적 연구)

  • Cho, Jang-Se;Kim, Min-Sook;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • This study carried out shear experiment for concrete deep beam reinforced FRP(Fiber Reinforced Polymers) bar to investigate shear strength of deep beam. The test conducted for 15 specimens, and the variables were shear span-to-depth ratio, reinforcement ratio, effective depth, reinforcement components of shear strength. crack, deflection are investigated based on shear experimental. We compared shear strength using ACI 318-08 STM with proposed equations that considered arching action according to shear span-to-depth ratio. Consequently shear strength of deep beam reinforced FRP bar presented higher shear strength than steel bar. ACI STM's predictions are better accurate than other predicting equations.

The Effect of Shear Span-to-Effective Depth Ratio of Reinforced high Strength Concrete Deep Beam (고강도 철근콘크리트 춤이 큰 보의 전단스팬비 효과)

  • 오정근;성열영;안종문;이광수;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.225-231
    • /
    • 1997
  • 콘크리트 압축강도 및 전단스팬비의 변화에 의한 고강도 철근콘크리트 춤이 큰 보의 전단거동 및 내력특성을 파악하기 위한 실험적 연구를 하였다. 춤이 큰 보는 하중작용점과 하중지지점을 연결하는 사균열의 확대에 의해 취성전단파괴양상을 나타내었으며 하중작용점 하중 지지점의 콘크리트 압괴를동반하는 전단압축 및 전단인장파괴 형태로 최종파괴되었다. 전단스팬비가 감소함에 따라 사균열전단응력 및 최대전단응력은 크게 증가하였으며, ACI 및 CIRIA규준식은 부재의 최대전단응력을 비교적 정확하게 예측하고 있음을 파악하였다.

Energy absorption of reinforced concrete deep beams strengthened with CFRP sheet

  • Panjehpour, Mohammad;Abang Ali, Abang Abdullah;Aznieta, Farah Nora
    • Steel and Composite Structures
    • /
    • v.16 no.5
    • /
    • pp.481-489
    • /
    • 2014
  • The function of carbon fibre reinforced polymer (CFRP) reinforcement in increasing the ductility of reinforced concrete (RC) deep beam is important in such shear-sensitive RC member. This paper aims to investigate the effect of CFRP-strengthening on the energy absorption of RC deep beams. Six ordinary RC deep beams and six CFRP-strengthened RC deep beams with shear span to the effective depth ratio of 0.75, 1.00, 1.25, 1.50, 1.75, and 2.00 were tested till failure in this research. An empirical relationship was established to obtain the energy absorption of CFRP-strengthened RC deep beams. The shear span to the effective depth ratio and growth of energy absorption of CFRP-strengthened deep beam were the significant factors to establish this relationship.

Fuzzy modelling approach for shear strength prediction of RC deep beams

  • Mohammadhassani, Mohammad;Saleh, Aidi MD.;Suhatril, M;Safa, M.
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.497-519
    • /
    • 2015
  • This study discusses the use of Adaptive-Network-Based-Fuzzy-Inference-System (ANFIS) in predicting the shear strength of reinforced-concrete deep beams. 139 experimental data have been collected from renowned publications on simply supported high strength concrete deep beams. The results show that the ANFIS has strong potential as a feasible tool for predicting the shear strength of deep beams within the range of the considered input parameters. ANFIS's results are highly accurate, precise and therefore, more satisfactory. Based on the Sensitivity analysis, the shear span to depth ratio (a/d) and concrete cylinder strength ($f_c^{\prime}$) have major influence on the shear strength prediction of deep beams. The parametric study confirms the increase in shear strength of deep beams with an equal increase in the concrete strength and decrease in the shear span to-depth-ratio.