• Title/Summary/Keyword: space VLBI

Search Result 253, Processing Time 0.023 seconds

Estimation of Sejong VLBI IVP Point Using Coordinates of Reflective Targets with Their Measurement Errors (반사타겟 좌표 및 오차정보를 이용한 세종 VLBI IVP 위치계산)

  • Hong, Chang-Ki;Bae, Tae-Suk;Yi, Sangoh
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.717-723
    • /
    • 2020
  • Determination of local tie vectors between the space geodetic techniques such as VLBI (Very Long Baseline Interferometer), SLR (Satellite Laser Ranging), DORIS (Doppler Orbit determination and Radiopositioning Integrated on Satellite), GNSS (Global Navigation Satellite System) is essential for combination of ITRF (International Terrestrial Reference Frame). Therefore, it is required to compute IVP (Invariant Point) position of each space geodetic technique with high accuracy. In this study, we have computed Sejong VLBI IVP position by using updated mathematical model for adjustment computation so that the improvement on efficiency and reliability in computation are obtained. The measurements used for this study are the coordinates of reflective targets on the VLBI antenna and their accuracies are set to 1.5 mm for each component. The results show that the position of VLBI IVP together with its standard deviation is successfully estimated when they are compared with those of the results from previous study. However, it is notable that additional terrestrial surveying should be performed so that realistic measurement errors are incorporated in the adjustment computation process.

Current Status and Future Prospects of Korean VLBI Network (KVN)

  • Jung, Taehyun;Sohn, Bong Won;So, Byunghwa;Oh, Chungsik;Je, Do-Heung;Byun, Do-Young;Jung, Dong-Kyu;Roh, Duk Gyoo;Lee, Euikyum;Kim, Hyo Ryoung;Kim, Hyun-Goo;Byun, Hyungkyu;Chung, Hyunsoo;Yim, In Sung;Kim, Jae-Young;Kim, Jaeheon;Yeom, Jaehwan;Shin, Jaesik;Park, Jeong-Je;Kim, Jeong-Sook;Hwang, Jungwook;Wajima, Kiyoaki;Song, Min-Gyu;Chung, Moon-Hee;Sakai, Nobuyuki;Lee, Sang-Hyun;Lee, Sang-Sung;Oh, Sej-Jin;Wi, Seog Oh;Kim, Seungrae;Kim, Soon-Wook;Lee, Sung-Mo;Kang, Yong-Woo;Minh, Young Chol;Kim, Young-Sik;Yun, Youngjoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.60.3-61
    • /
    • 2021
  • The Korean VLBI Network (KVN) consists of three 21m radio telescopes installed in Seoul, Ulsan, and Jeju Island with the world's first 4-channel receiver that can observe four different frequencies (e.g., 22, 43, 86, 129 GHz) simultaneously. This receiving system of KVN is particularly effective in millimeter-wavelength VLBI (mm-VLBI) observations by compensating fast atmospheric fluctuations effectively. This technology is now being enhanced with a compact triple-band receiver, becoming the world standard for a mm-VLBI system. In 2020, KVN supported 54 observing programs (KVN: 28, EAVN: 26) including the 2nd KVN Key Science Program (KSP) which supports 8Gbps data recording rate and the East Asian VLBI Network (EAVN) programs. KVN also participated in the European VLBI Network (EVN) and GMVA (Global Millimeter VLBI Array) sessions regularly. Here, we report current status and future propsects of KVN.

  • PDF

Development of Software Correlator for KJJVC (한일공동VLBI상관기를 위한 소프트웨어 상관기의 개발)

  • Yeom, J.H.;Oh, S.J.;Roh, D.G.;Kang, Y.W.;Park, S.Y.;Lee, C.H.;Chung, H.S.
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.567-588
    • /
    • 2009
  • Korea-Japan Joint VLBI Correlator (KJJVC) is being developed by collaborating KASI (Korea Astronomy and Space Science Institute), Korea, and NAOJ(National Observatory of Japan), Japan. In early 2010, KJJVC will work in normal operation. In this study, we developed the software correlator which is based on VCS (VLBI Correlation Subsystem) hardware specification as the core component of KJJVC. The main specification of software correlator is 8 Gbps, 8192 output channels, and 262,144-points FFT (Fast Fourier Transform) function same as VCS. And the functional algorithm which is same as specification of VCS and arithmetic register are adopted in this software correlator. To verify the performance of developed software correlator, the correlation experiments were carried out using the spectral line and continuum sources which were observed by VERA (VLBI Exploration of Radio Astrometry), NAOJ. And the experimental results were compared to the output of Mitaka FX correlator by referring spectrum shape, phase rate, and fringe detection and so on. Through the experimental results, we confirmed that the correlation results of software correlator are the same as Mitaka FX correlator and verified the effectiveness of it. In future, we expect that the developed software correlator will be the possible software correlator of KVN (Korean VLBI Network) with KJJVC by introducing the correlation post-processing and modifying the user interface as like GUI (Graphic User Interface).

A Study on the Development of Playback Control Software for Mark5B VSI System

  • Oh, S.J.;Yeom, J.H.;Roh, D.G.;Chung, H.S.;Kim, K.D.;Cappallo, Roger
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.107-116
    • /
    • 2010
  • We developed the playback control software for a high-speed playback system which is a component of the Korea-Japan Joint VLBI Correlator (KJJVC). The Mark5B system, which is a recorder and playback system used in the Korean VLBI Network (KVN), has two kinds of operation mode. That is to say, the station unit (SU) mode, which is for the present Mark4 system, and the VSI mode, which is for the new VLBI standard interface (VSI) system. The software for SU is already developed and widely used in the Mark4 type VLBI system, but the software for VSI has only been developed for recording. The new VLBI system is designed with a VSI interface for compatibility between different systems. Therefore, the playback control software development of the VSI mode is needed for KVN. In this work, we developed the playback control software of the Mark5B VSI mode. The developed playback control software consists of an application part for data playing back, a data input/output part for the VSI board, a module for the StreamStor RAID board, and a user interface part, including an observation time control part. To verify the performance of developed playback control software, the playback and correlation experiments were performed using the real observation data in Mark5B system and KJJVC. To check the observation time control, the data playback experiment was performed between the Mark5B and Raw VLBI Data Buffer (RVDB) systems. Through the experimental results, we confirmed the performance of developed playback control software in the Mark5B VSI mode.

MOGABA: Monitoring of Gamma-ray Bright AGN with KVN 21-m radio telescopes at 22 and 43GHz

  • Lee, Sang-Sung;Yang, Ji-Hae;Byun, Do-Young;Sohn, Bong-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.59.2-59.2
    • /
    • 2011
  • We introduce an ongoing project for monitoring total flux density at 22 and 43GHz, linearly polarized flux, and polarization angle at 22GHz of Gamma-ray bright AGN (Active Galactic Nuclei) with KVN (Korean VLBI Network) 21-m radio telescopes. The project started in May, 2011 with an effective monitoring cycle of 4 days, observing four main objects (3C 454.3, BL Lac, 3C 273, and 3C 279). More objects were included in the source list when they had flared in Gamma-ray. In this paper, we report the current status of the project and preliminary results for the monitoring observations.

  • PDF

Flux Monitoring of Intraday Variable Sources with KVN Yonsei Radio Telescope

  • Lee, Jee-Won;Sohn, Bong-Won;Byun, Do-Young;Lee, Jeong-Ae;Park, Pulun;Kim, Min-Joong;Kim, Sung-Soo S.
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.34.3-34.3
    • /
    • 2010
  • We present the results of flux monitoring of BL Lac object 0716+71 and 0954+65 at 22GHz and 43GHz. Both of the flat spectrum radio sources are known as Intraday variables (IDVs) which are characterized by fast flux variation on time scales of a day or less. In general, the IDV phenomenon is interpreted as the effect of refractive scintillation in the interstellar medium or the evidence of source intrinsic flux variation. The observations were made simultaneously at 22GHz and 43GHz with KVN Yonsei 21m radio telescope.

  • PDF

A Study on Comparison of Massive Data Recording Equipments for VLBI Radio Observation Data (VLBI 전파 관측데이터를 위한 대용량 기록장치 비교에 관한 연구)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • KVN(Korean VLBI Network) introduced the Mark6 system of the MIT haystack observatory as a recorder for data recording up to 32 Gbps for VLBI(Very Long Baseline Interferometry) observation. The Mark6 recorder can record data at up to 32Gbps when two systems and 64 HDDs are installed. However, because of the unique recording method that is characteristic of Mark6, we are introducing a large amount of data into a virtual file system, or using a general RAID method, which causes data loss when reading and transferring files at the highest recording speed or file system have. The Flexbuff system, a software recorder developed by JIVE(Joint Institute for VLBI ERIC), can be configured to operate as a data recorder through RAID configuration and network upgrades. In particular, when installed in the Mark6 system, it can record VLBI data at a maximum speed of 32 Gbps with less loss of data compared to the existing Mark6 by utilizing Mark6 resources well. In this paper, we propose that the existing Mark6 system can be operated as Mark6-Flexbuff by installing jive5ab software, and it is verified through experiment that it can be effectively used for VLBI observation operation through data recording test.

PERFORMANCE EVALUATION AND IMPLEMENTATION OF CLOCK SYSTEM FOR KOREAN VLBI NETWORK (한국우주전파관측망(KVN)을 위한 시각 시스템 구축과 성능측정)

  • Oh, Se-Jin;Je, Do-Heung;Lee, Chang-Hoon;Roh, Duk-Gyoo;Chung, Hyun-Soo;Byun, Do-Young;Kim, Kwang-Dong;Kim, Hyo-Ryung;Jung, Gu-Young;Ahn, Woo-Jin;Hwang, Jeong-Wook
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.4
    • /
    • pp.189-199
    • /
    • 2007
  • In this paper, we describe the proposed KVN (Korean VLBI Network) clock system in order to make the observation of the VLBI effectively. In general, the GPS system is widely used for the time information in the single dish observation. In the case of VLBI observation, a very high precise frequency standard is needed to perform the observation in accordance with the observation frequency using the radio telescope with over 100km distance. The objective of the high precise clock system is to insert the time-tagging information to the observed data and to synchronize it with the same clock in overall equipments which used in station. The AHM (Active Hydrogen Maser) and clock system are basically used as a frequency standard equipments at VLBI station. This system is also adopted in KVN. The proposed KVN clock system at each station consists of the AHM, GPS time comparator, standard clock system, time distributor, and frequency standard distributor. The basic experiments were performed to check the AHM system specification and to verify the effectiveness of implemented KVN clock system. In this paper, we briefly introduce the KVN clock system configuration and experimental results.

Current Status of Development of High Speed Sampler with VDIF outport for e-VLBI

  • Kang, Yong-Woo;Song, Min-Gyu;Je, Do-Heung;Wi, Seog-Oh;Byun, Do-Young;Nam, Wook-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.84.2-84.2
    • /
    • 2013
  • KVN 샘플러의 국산화를 위하여, 우리는 지난 3년간의 연구로 1GHz 샘플러 Proto-Type을 설계하고 제작하였다. 첨단망인 KREONET을 이용하여 각 전파천문대를 연결하고, 바로 대전 센터로 관측 데이터를 전송하는 e-VLBI를 구현할 수 있다면, 연구의 가치와 효율을 극대화 할 수 있다. 이를 위하여 샘플러에서 직접 첨단망으로 VDIF(VLBI Data Interchange Format, VLBI 자료전송 규격)의 자료를 보낼 수 있게 새로운 샘플러를 설계하고 제작하고자 한다.

  • PDF

e-VLBI 실현을 위한 초고속 네트워크 설계

  • 송민규;김현구;김광동;노덕규;위석오;오세진
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.79-79
    • /
    • 2003
  • e-VLBI(electronic VLBI)는 각 관측 사이트에서 얻은 대용량의 VLBI 데이터를 영상합성처리 센터로 전송하기 위하여 네트워크를 이용하는 기술이다. 이는 전세계의 관측소에서 얻어낸 막대한 용량의 데이터를 실시간, 준-실시간 형태로서 데이터센터에 전송할 수 있는 유일한 방법으로서 초고속정보통신망을 적극적으로 활용하는 애플리케이션이라 할 수 있다. 한국천문연구원에서는 현재 2007년 완공을 목표로 연세대, 울산대, 탐라대에 건설되는 20m 안테나와 대덕전파천문대의 14m 안테나를 네트워크로 연결하는 e-KVN(Korean VLBI Network) 계획을 추진중에 있으며 이는 각 관측소에서 얻은 VLBI 데이터를 네트워크를 통하여 1024Mbps로 데이터센터까지 실시간으로 전송하는 것을 그 궁극적 목표로 하고 있다. 이러한 e-VLBI를 구현함에 있어서 첨단화된 네트워크 및 하드웨어 기술은 필수라고 할 수 있는데 본 연구에서는 e-KVN의 백본망으로서 예상되고 있는 KOREN과 10GbE으로 구성된 네트워크 토폴로지에 대해 간략히 기술하고 e-KVN의 향후 전망 및 보완해야 할 네트워크 기술에 대해 살펴보고자 한다.

  • PDF