Abstract

In this paper, we describe the proposed KVN (Korean VLBI Network) clock system in order to make the observation of the VLBI effectively. In general, the GPS system is widely used for the time information in the single dish observation. In the case of VLBI observation, a very high precise frequency standard is needed to perform the observation in accordance with the observation frequency using the radio telescope with over 100km distance. The objective of the high precise clock system is to insert the time-tagging information to the observed data and to synchronize it with the same clock in overall equipments which used in station. The AHM (Active Hydrogen Maser) and clock system are basically used as a frequency standard equipments at VLBI station. This system is also adopted in KVN. The proposed KVN clock system at each station consists of the AHM, GPS time comparator, standard clock system, time distributor, and frequency standard distributor. The basic experiments were performed to check the AHM system specification and to verify the effectiveness of implemented KVN clock system. In this paper, we briefly introduce the KVN clock system configuration and experimental results.

Keywords

References

  1. 김효령 외, 2006, 2006년도 한국우주전파관측망 구축사 업 결과보고서,한국천문연구원
  2. 오세진 외, 2004, VLBI의 기준주파수와 시각동기 시스 템, 천문학논총, 19, 95
  3. Imamura Kuniyasu 외, 2003, Time distribution using the network, CRL Report, 46, 1/2, 203
  4. ECHO사, 2007, AQ-330C5B user's manual
  5. ECHO사, 2007, GP-1100C user's manual
  6. KVARZ사, 2007, CH1-75A operation manual
  7. Symmetricom사, 2007, SyncServer S250 user's manual

Cited by

  1. Design and Development of a High-Speed Data-Acquisition System for the Korean VLBI Network vol.63, pp.6, 2011, https://doi.org/10.1093/pasj/63.6.1229