• Title/Summary/Keyword: source-synchronous

Search Result 238, Processing Time 0.029 seconds

Speed Control of PMSM with Current Controller in Overmodulation Region (과변조 영역에서의 전류제어를 가지는 영구자석형 동기 전동기의 속도제어)

  • Park, Jin-Sik;Kim, Hag-Wone;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.251-253
    • /
    • 2005
  • This paper presents a study on a current control of a PM synchronous motor which is fed by two-level voltage source inverter in the high modulation index area. In order to increase dynamic response and extend speed limit caused by voltage limit, overmodulation method is generally used. The current control in overmodulation have voltage limit. So larger voltage command than voltage limit should be diminished. In this paper, the problem conventional normalization method is analyzed and New normalization method in overmodulation region is proposed.

  • PDF

Design and Implementation of Xcent-Net

  • Park, Kyoung;Hahn, Jong-Seok;Sim, Won-Sae;Hahn, Woo-Jong
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.74-81
    • /
    • 1997
  • Xcent-Net is a new system network designed to support a clustered SMP called SPAX(Scalable Parallel Architecture based on Xbar) that is being developed by ETRI. It is a duplicated hierarchical crossbar network to provide the connections among 16 clusters of 128 nodes. Xcent-Net is designed as a packet switched, virtual cut-through routed, point-to-point network. Variable length packets contain up to 64 bytes of data. The packets are transmitted via full duplexed, 32-bit wide channels using source synchronous transmission technique. Its plesiochronous clocking scheme eliminates the global clock distribution problem. Two level priority-based round-robin scheme is adopted to resolve the traffic congestion. Clear-to-send mechanism is used as a packet level flow control scheme. Most of functions are built in Xcent router, which is implemented as an ASIC. This paper describes the architecture and the functional features of Xcent-Net and discusses its implementation.

  • PDF

Dead-time compensation algorithm on synchronous frame for 3-phase inverter (3상 인버터를 위한 동기좌표계에서의 위치기반 데드타임 보상알고리즘)

  • Lim, Jeongwoo;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.27-29
    • /
    • 2018
  • 본 논문은 상 전류의 위치(전기각)를 기반으로 보상전압을 결정하는 새로운 데드타임 보상알고리즘을 제안한다. 제안하는 알고리즘은 보상전압을 결정하는데 있어, 전류의 극성대신 제어하는 상 전류의 위치(전기각)를 이용하기 때문에 추가적인 알고리즘 없이 간단하게 보상전압을 정의할 수 있다. 또한 제안하는 데드타임 보상알고리즘은 동기좌표계에 바로 적용가능하기 때문에 3상 전압형 인버터(VSIs; Voltage Source Inverters)에 일반적으로 사용되는 동기좌표기반 제어기에 적용이 용이하고 추가적인 변환과정 없이 동기좌표에서의 인버터 출력전압을 추정할 수 있다. 제안하는 데드타임 보상알고리즘의 효과와 성능을 검증하기 위하여 전압형 3상 인버터를 이용한 L-R부하 실험이 진행되었으며, 상 전류파형의 FFT(Fast Fourier Transfrom)와 THD(Total Harmonic Distortion)를 산정하여 정량적 분석을 병행하였다.

  • PDF

Comparison of High Power Semiconductor Devices in 5MW PMSG MV Wind Turbines

  • Lee, Kihyun;Jung, Kyungsub;Suh, Yongsug;Kim, Changwoo;Cha, Taemin;Yoo, Hyoyol;Park, Sunsoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.386-387
    • /
    • 2013
  • This paper provides a comparison of high power semiconductor devices in 5MW-class Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) wind turbines. High power semiconductor devices of IGBT module type, IGBT press-pack type, and IGCT of both 4.5kV and 6.5kV are considered in this paper. Benchmarking is performed based on neutral-point clamed 3-level back-to-back type voltage source converter supplied from grid voltage of 4160V. The feasible number of semiconductor devices in parallel is designed through the loss analysis considering both conduction and switching losses under the given operating conditions of 5MW-class PMSG wind turbines, particularly for the application in offshore wind farms. The loss analysis is confirmed through PLECS simulations. The comparison result shows that IGBT press-pack type semiconductor device has the highest efficiency and IGCT has the lowest cost factor considering the necessary auxiliary components.

  • PDF

ave PWM Inverter (안정파PWM인버어터를 위한 새로운 디지털방식)

  • 정연택;한경희;이종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.2
    • /
    • pp.80-88
    • /
    • 1988
  • As a method to improve harmonics in the voltage source PWM inverter, 5 level stair case wave method is used. The complementary transistor inverter (CTI) bridge circuit has this characteristics. This circuit required synchronous type 3 level PWM signal. In this paper, the 3 phase PWM digital signals within about 10 modulation error of the natural sampling was caculated, and a ROM table out of it for the digital signal of the control system was made. According to this table, the digital control method was proposed, and DTI circuit operated by this method was reviewed. It was confirmed to make V/F control possible by the select modulation ratio to the frequency.

Position Control of Brushless DC moror by Field Oriented Control (자속 기준 제어에 의한 브러쉬 없는 직류전동기의 위치제어)

  • 조관열;신휘범;한재원;윤명중
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.9
    • /
    • pp.600-608
    • /
    • 1988
  • Although the structure of brushless dc motor is similar to that of a Permanent magnet synchronous motor, its torque-speed characteristcis are the same as those of a permanent magmet dc motor. The brushless dc motor drive systemcomposed of power converter including inverter, rotor positioning sensor and controller has been investigated for the purpose of position control when the motor is fed by a current controlled voltage source inverter. The equivalent transformation of a brushless dc motor into an separately exited dc motor has been possible with the vector control (field oriented control) technique. It is shown in this paper that the position control of a brushless dc mitor can be done fairly accurately only using q-axis current.

  • PDF

A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization (PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구)

  • Ahn Jong-Bo;Kim Won-gon;Hwang Ki-Hyun;Park Jun-H
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

PSCAD/EMTDC BASED MODELING AND ANALYSIS OF A GRID-CONNECTED VARIABLE SPEED WIND ENERGY CONVERSION SCHEME (계통연계형 가변속 풍력발전방식의 PSCAD/EMTDC 모의 및 해석)

  • 김슬기;김응상
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.413-419
    • /
    • 2003
  • The paper presents a simulation model and analysis of a grid-connected variable speed wind energy conversion scheme (VSWECS) using the PSCAD/EMTDC software. The modeled system uses a variable speed drive, a fixed pitch angle, a synchronous generator as a wind generator and an AC-DC-AC conversion scheme, which facilitates the wind generation to efficiently operate under varying wind speed while connected to the distribution network. The power output of the WECS is controlled by the AC-DC-AC conversion scheme, the objective of which is to capture the maximum active power under varying wind conditions and to keep the voltage magnitude of the terminal bus at a specific level. Aerodynamic models are applied for a wind turbine model. An simulation analysis of the scheme in terms of its responding to wind variations is also presented.

Improved Direct Power Control of Shunt Active Power Filter with Minimum Reactive Power Variation and Minimum Apparent Power Variation Approaches

  • Trivedi, Tapankumar;Jadeja, Rajendrasinh;Bhatt, Praghnesh
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1124-1136
    • /
    • 2017
  • Direct Power Control technique has become popular in the grid connected Voltage Source Converter (VSC) applications due to its simplicity, direct voltage vector selection and improved dynamic performance. In this paper, a direct method to determine the effect of voltage vector on the instantaneous active and reactive power variations is developed. An alternative Look Up Table is proposed which minimizes the commutations in the converter and results in minimum reactive power variation. The application of suggested table is established for Shunt Active Power Filter (SAPF) application. The Predictive Direct Power Control method, which minimizes apparent power variation, is further investigated to reduce commutations in converters. Both the methods are validated using 2 kVA laboratory prototype of Shunt Active Power Filters (SAPF).

Parallel Operation Control Technique of On-line UPS System (온라인 무정전전원장치의 병렬운전 제어기술)

  • Cho J.S.;Kang B.H.;Gho J.S.;Choe G.H.;Kim J.H.;Chung S.E.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF