Improvement of Calculation Accuracy in the Electron Monte Carlo Algorithm with Optional Air Profile Measurements

  • Sung, Jiwon;Jin, Hyeongmin;Kim, Jeongho;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.163-171
    • /
    • 2020
  • Purpose: In this study, the accuracies of electron Monte Carlo (eMC) calculation algorithms were evaluated to determine whether electron beams were modeled by optional air profiles (APs) designed for each applicator size. Methods: Electron beams with the energies of 6, 9, 12, and 16 MeV for VitalBeam (Varian Medical System, Palo Alto, CA, USA) and 6, 9, 12, 16, and 20 MeV for Clinac iX (Varian Medical System) were used. Optional APs were measured at the source-to-detector distance of 95 cm with jaw openings appropriate for each machine, electron beam energy, and applicator size. The measured optional APs were postprocessed and converted into the w2CAD format. Then, the electron beams were modeled and calculated with and without optional APs. Measured profiles, percentage depth doses, penumbras with respect to each machine, and energy were compared to calculated dose distributions. Results: For VitalBeam, the profile differences between the measurement and calculation were reduced by 0.35%, 0.15%, 0.14%, and 0.38% at 6, 9, 12, and 16 MeV, respectively, when the beams were modeled with APs. For Clinac iX, the differences were decreased by 0.16%, -0.31%, 0.94%, 0.42%, and 0.74%, at 6, 9, 12, 16, and 20 MeV, respectively, with the insertion of APs. Of note, no significant improvements in penumbra and percentage depth dose were observed, although the beam models were configured with APs. Conclusions: The accuracy of the eMC calculation can be improved in profiles when electron beams are modeled with optional APs.

LED를 이용한 가시광 무선 통신 링크 (Visible Light Wireless Communication Link Using LEDs)

  • 손용환;안성찬;김현승;원용욱;한상국
    • 전기전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.70-74
    • /
    • 2009
  • 본 논문에서는 백색 LED와 PD를 이용하여 가시광 무선 통신 링크를 제안하였다. 제안된 구조는 Q-factor와 eye pattern을 이용하여 실험을 통해 그 특성을 분석하였다. 또한, 일반적으로 사용되는 조명용 형광등을 이용하여 간섭광 잡음 환경에 대한 송, 수신 특성을 분석하였다. LED와 PD 모듈간의 거리가 1m일 경우, 10Mb/s 까지 비트 오율 없이 전송 가능함을 알 수 있었으며, 간섭광 잡음 환경 하에서는 5Mb/s 까지 낮은 비트오율로 전송 가능함을 알 수 있었다. 또한, 수신기의 위치가 중심축으로부터 5cm 와 10cm 떨어진 거리에 위치해 있는 경우 각각 10Mb/s와 1Mb/s 의 데이터까지 낮은 비트오율로 전송 가능함을 알 수 있었다.

  • PDF

표면 요철 측정을 위한 광학적 거리 측정기 개발 (Development of an Optical Range Finder for Surface Roughness Measurements)

  • 엄정현;박현희;서동선;허웅;김준범;김용곤
    • 전기전자학회논문지
    • /
    • 제2권1호
    • /
    • pp.53-60
    • /
    • 1998
  • 고속도로 등의 대형 구조물의 표면 요철을 측정하기 위한 높은 반복율의 광학적 근 거리 측정기를 개발하였다. 삼각 측정법의 원리에 의한 거리 계측을 위해, 광원으로는 발광 다이오드를 사용하였으며 물체에서 반사된 광의 각도 검출기로는 1차원 위치 감응 광 검출기를 사용하였다. 개발된 거리 측정기는 물체의 반사율 변화를 극복하기 위한 자동 전력 조절 기능과 일정한 배경 광잡음은 물론 시간에 대해 변하는 배경 광잡음까지도 제거할 수 있는 전기적 배경잡음 제거기능을 갖고 있다. 거리 측정기의 장착 및 요철의 깊이를 고려하여 설정된 $22{\sim}38cm$의 측정거리에 대한 실험결과, 물체의 반사율에 관계없이 ${\pm}1.5mm$ 이내의 측정오차를 보였다.

  • PDF

Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가 (Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy)

  • 연준호;김수영;최성욱;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.76-82
    • /
    • 2011
  • Lymphatic scintigraphy는 림프계 진단에 있어 절대표준검사로 흔히 이용되고 있으며 림프부종의 진단, 치료방침의 설정, 치료 후 평가 등에 유용한 검사이다.1) 상 하지 검사 중 하지에 부종이 있는 환자의 검사에서 무의식적인 환자의 움직임이나 1분, 1시간, 2시간 검사의 동일한 자세 유지가 되지 않을 경우 정량 분석에 영향을 주었다. GE사의 Infinia 장비를 이용하여 방사성의약품 $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4개를 2010년 6월에서 8월 사이에 내원하는 환자 40명에게 피하주사를 하여 정량 분석을 비교하였다. 환자의 발을 고정한 상태와 고정하지 않은 상태로 영상을 얻어 발의 자세 변경이 연부조직과 뼈에 의해 계측 값의 변화가 있는지 확인하였다. 또한 발의 자세 변경으로 검출기와 주사부위의 거리 변화에 따른 계측 값의 차이를 알아보기 위해 $^{99m}Tc\;600{\mu}Ci$ 점선원과 검출기와의 거리를 2 cm씩 거리를 증가시켜 5회 측정하였다. 마지막으로 $^{99m}Tc$-phytate가 림프선을 따라 이동하는 양의 차이가 정량 분석 값에 영향을 주는 지 알아보기 위해 같은 자세로 주사 후 1분, 6분 lymphatic scintigraphy 영상을 얻어 비교하였다. 주사 후 1분 검사에서 발을 고정한 상태와 고정하지 않은 상태를 비교했을 때 오차 값에 대한 편차 백분율 값은 최소 2.7%에서 최대 25.8%의 값을 얻었다. 그리고 거리 변화에 따른 계측 값은 기준 값이 평균 176,587 counts이고 2 cm 간격으로 거리를 증가시켜 측정한 결과 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm)로 나타나 편차 백분율이 1.27, 1.79, 2.04, 2.42, 2.32%로 2.5%를 넘지 않음을 알 수 있었다. 또한, 피하주사 후 스캔까지 6분 이내에 림프선을 타고 이동한 양을 평가한 결과 최소 0.15%에서 최대 2.3%만큼 림프선을 타고 이동하였다. 이는 거리에 따른 편차 백분율 2.42%를 제외시키고 림프선에 의한 최대 변동 값인 2.3%를 제외하더라도 자세 변경으로 인한 연부조직과 bone에 의한 감소가 20%이상의 큰 차이가 나타난 것을 알 수 있다. 부종이 있는 환자의 림프 흐름을 평가하고 림프계에 의해 섭취되는 양을 정량 분석하는 lymphatic scintigraphy는 동일 환자의 1분, 1시간, 2시간 검사에서 다른 자세가 발생할 경우 뼈와 연부조직에 의한 감약으로 최대 25.8%의 차이를 나타냈으며, 통계적 검증 결과도 발을 고정한 상태와 고정하지 않은 상태는 유의한 차이를 보였다. 그리고 자세 변경으로 인한 검출기와의 거리 차이, 피하 주사 후 검사 시간까지의 차이로 인한 계수 값의 변화는 상대적으로 작지만 정량 분석 시 정확한 결과를 얻지 못하는 요인임을 알 수 있었다. 그러므로 정량 분석을 위한 lymphatic scintigraphy에서는 반드시 자세 고정을 위한 노력과 고정물 제작 활용이 선행되어야 할 것이다.

  • PDF

산업재해 안전을 위한 New Austria Tunnel Method 수지에서 빔산란에 관한 Monte Carlo 시뮬레이션에 관한 연구 (A Study on Monte Carlo Simulation by Beam Scattering in Resin of New Austria Tunnel Method for Safety of Industrial Disaster)

  • 김기준;이주엽
    • 한국응용과학기술학회지
    • /
    • 제29권3호
    • /
    • pp.473-479
    • /
    • 2012
  • 혼탁매질에서 산란체와 흡수체의 영향은 빛산란에 의해 파장에 대한 산란세기로 설명된다. New Austria Tunnel Method의 수지에 대한 산란의 분자특성들은 연구하기 위해 Monte Carlo Simulation하였다. 이는 산란매질에서 광학적 파라미터들(${\mu}_s$, ${\mu}_a$, ${\mu}_t$)에 의해 조사되어 그들의 영향을 알 수 있었다. 산란매질에서 광자에 대한 빛분포에 의한 결과는 광원에서 검출기까지 거리가 가까우면 산란이 증가하여 산란세기가 크게 나타났다. 이는 강구조물의 내구성을 위한 코팅과 부식에서 좋은 모델을 디자인하는데 도움이 될 것이다.

근접치료용 방사성 동위원소의 선량분포 확인을 위한 디지털 반도체 센서의 제작 및 평가 (Evaluation of Fabricated Semiconductor Sensor for Verification of γ-ray Distribution in Brachytherapy)

  • 박정은;김교태;최원훈;이호;조삼주;안소현;김진영;송용근;김금배;허현도;박성광
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.280-285
    • /
    • 2015
  • 방사선 치료분야 중 근접치료는 방사성 동위원소를 체내에 직접 삽입하여 병변 세포를 사멸시키는 치료법으로써, 주로 고선량률 치료가 시행되고 있다. 현재 치료계획과 실제 선량 방출범위의 일치성 여부는 Film/Screen 시스템을 통해 확인하고, 확인된 선량분포에 따라 방사선 치료를 시행하고 있다. 선량 분포 확인 시 F/S 시스템을 이용할 경우, Film 현상조건에 따른 신호 왜곡과 반음영에 의한 저분해능으로 인하여 치료계획과의 선량 분포 일치성을 정량적으로 파악하기 힘든 단점이 있다. 본 연구에서는 방사선 근접치료 시 치료계획과 동일한 선량 분포 여부를 확인하는 디지털 검출시스템의 기초 연구를 진행하고자, PIB법을 이용한 $HgI_2$ 반도체 검출센서를 제작하였다. 또한 이를 근접치료선원을 이용해 평가함으로써, QA 시스템으로 이용 가능성을 검증하고자 하였다. 근접치료 범위의 확인을 위하여 SDD의 변화에 대한 신호 수집량을 평가한 결과, 치료 범위 이상의 거리에서는 산란선으로 추정되는 낮은 신호만이 측정되었으므로 치료 계획시와 동일한 치료 범위를 정량적으로 확인할 수 있었다. 또한 동일한 ${\gamma}$-선 조사 조건에 대한 재현성 평가 결과, 변동계수 1.5% 이내인 것을 확인하였다. 이와 같은 결과를 바탕으로, 본 연구에서 제작한 센서는 방사선 근접치료 QA 시스템으로 적용 가능할 것이라 사료된다.

Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구 (Radiographic Study of Cobey Method and Modified Cobey Method)

  • 고유림;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

Mechanical Check용 Spherical Device의 제작 및 특성 평가 (Practicability Assessment of Spherical Type Mechanical Check Device (SMCD))

  • 이병구;김건오;권영호
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.55-62
    • /
    • 2007
  • 목 적: PACS의 도입에 발맞추어 시작된 디지털 의료영상은 현재 방사선 진단 및 치료 영역에서 일반화되었으며 특히 진단 영역에서는 눈부신 발전을 거듭하고 있다. 치료영역에서의 디지털 영상 구현은 상대적으로 느린 성장과정을 거쳐 오늘에 이르고 있다. 본 논문은 이러한 아날로그에서 디지털로 변화하는 흐름을 인식하여 정도관리(Quality Assurance) 업무 중 기계적 점검(Mechanical check) 부분을 디지털 영상 기반 업무로 대체하여 수행하고, 기존의 육면체 또는 사각형틀의 개념을 탈피한 구형(球形)의 Spherical type mechanical check device (SMCD)를 고안하여 그 실용성을 실험하였다. 대상 및 방법: 선원에서 영상 detecter 간의 거리가 항상 일정하고, SMCD의 중심까지 거리가 일정하다면 어느 방향에서 방사선으로 SMCD를 조사하더라도 그 크기는 항상 일정하게 영상으로 표현 될 것이다. 이를 위해 Polyester P.E 재질의 정확한 반구(半球) 2개를 자체 제작하여 그것을 합쳤을 때 정원(正圓)의 구(球)가 되도록 하였다. 결 과: SMCD를 이용하여 방사선조사면과 광조사면의 일치도, 방사선조사면 크기의 정확도($5{\times}5$, $10{\times}10$, $15{\times}15cm^2$), Collimator field 크기의 정확도($5{\times}5$, $10{\times}10$, $15{\times}15cm^2$), Gantry rotation isocenter check, Collimator rotation isocenter check, Room laser accuracy check, Collimator rotation angle check와 Couch rotation angle check 등 기존의 기계적 점검을 디지털 영상을 이용하여 실행할 수 있었다. 결 론: 기존의 Flat 또는 정육면체 형태의 기계적 점검 장치로는 쉽게 하기 힘든 non-coplanar field에 적용되는 Gantry와 Couch가 동시에 rotation 되었을 때 그 isocenter의 일치도를 실시간으로 확인할 수 있었다.

  • PDF

선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰 (Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS))

  • 윤준;이귀원;박병문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권1호
    • /
    • pp.61-66
    • /
    • 2010
  • 선형가속기를 기반으로 하는 뇌정위적 방사선 수술에 있어 전용 콘과 동일한 정방형 조사면에서의 소조사면 선량특성에 관해 알아보고자 6 MV 광자선과 소조사면 전용 검출기를 이용해 측정하였다. 선원 표면간 거리는 100 cm로 하고, 전용 cone ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$과 정방형 조사면 $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$ 조사면 으로 1.5 cm, 5 cm, 10 cm, 20 cm, 30 cm 지점에서 심부선량을 측정하였고, 최대 선량점에서 각 조사면에서 출력선량을 측정하여 비교하였다. 반음영의 측정을 위한 선량측면도 측정은 ${\Phi}1\;cm$, ${\Phi}3\;cm$ 및 동일한 정방형 조사면에서 선원 표면간 거리 95 cm, 깊이 5 cm에서 SFD를 이용하여 측정하였다. 물리학적 조사면(90%) 내에서는 1 mm 간격으로, 반음영 영역(20~80%)에서는 0.5 mm 간격으로 측정하였다. 전용 콘 과 정방향 조사면의 PDD 변화는 기준조사면을 기준으로 5 cm 깊이에서 4.3~7.9% 낮게 나타났으며, 콘의 크기와 조사면 크기가 커질수록 PDD 변화는 적게 나타났다. 선질 비교를 위해 $PDD_{20,10}$를 비교한 결과 ${\Phi}1\;cm$ 콘과 $1{\times}1\;cm^2$을 제외한 다른 조사면에서는 1% 이내의 변화를 보였다. 출력선량은 콘을 이용한 방법에서 정방형 조사면에서 보다 3.1~4.6% 출력선량이 증가하였다. 반음영 영역은 ${\Phi}1\;cm$, ${\Phi}3\;cm$ 동일한 정방형 조사면에서 콘을 이용한 방법이 반음영 영역이 20% 감소하였다. 뇌정위적 방사선 수술은 소조사면을 이용해 1회 대선량을 조사하는 방법으로 조사면의 선량특성을 고려한 처방이 중요하게 된다. 본 실험을 통해 뇌정위적 방사선 수술에 있어 정방형 소조사면 보다 전용 콘을 이용한 방법이 유효하다고 사료되며, 향후 다양한 측정기를 이용한 소조사면의 선량특성에 관한 연구가 필요하다고 생각된다.

광자선을 이용한 전신 및 반신조사의 선량분포에 관한 고찰 (A study on the dose distribution for total-body & hemibody irradiation using clinical photon beams)

  • 김진기;권형철;김정수;오영기;김기환;신교철;김정홍;박충기;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.147-153
    • /
    • 2001
  • 방사선 전신 및 반신 조사방법을 방사선치료에 적용하여 균일한 선량 분포를 유도하고자 조사거리에서 선량측정, 조직결손에 따른 보상과 선량 보정 방법을 논의하였다. 의료용 선형가속기에서 발생된 6MV 광자선을 이용한 전신 조사시의 흡수선량을 결정하는, 선원과 조사면사이의 거리 변화에 따른 계산자료를 조사면의 중심축에서 고체 팬톰, RFA-7 물팬톰(Scanditronix, Sweden)에 대해 UNIDOS 전리함(PTW, Germany), THERADOS 전리함(Scanditronix, Sweden)을 이용한 측정으로 그 크기를 결정하였다. 조직보상체는 연판과 아크릴판을 이용하였다. 전신조사의 조건은 선원으로부터 380 cm의 거리에서 120 $\times$ 120 $cm^2$ ~ 152 $\times$ 152 $cm^2$ 의 조사면을 대상으로 하였다. 전신조사를 위한 기본 자료 측정에서 선원과 조사면의 거리 변화에 따른 흡수 선량 분포는 거리가 멀수록 더 증가하는 현상을 보였고, 조사면의 모서리부분은 약 10-20% 의 선량이 감소되었으나 굴곡좌위형 체위를 취함으로서 선량분포를 보완할 수 있었다. 연판과 아크릴판을 이용한 조직결손에 따른 보상체 제작으로 중심축 선량비를 $\pm$ 8% 이내로 감소시킬 수 있었다. 조직결손의 보상에 따른 선량계산을 고찰하여 임상 적용시 선량분포의 불균일성을 줄일 수 있었다.

  • PDF