• Title/Summary/Keyword: source effects

Search Result 4,012, Processing Time 0.034 seconds

Environmental Noise Prediction of Power Plants (발전소 환경소음 예측)

  • 조대승;유병호
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.621-629
    • /
    • 1997
  • For computer aided design and costruction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

Source Identification in an Interior Sound Field (반사파가 존재하는 실내 공간에서의 음원 탐지 방법)

  • 최영철;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1203-1209
    • /
    • 2001
  • Identification of noise sources, their locations and strengths, have been taken great attention. The method that can identify noise sources normally assumes that noise sources are located at a free field. However, the sound in a reverberant field consists of that coming directly from the source plus sound reflected or scattered by the walls or objects in the field. In contrast to the exterior sound field, reflections are added to sound field. Therefore, we have to consider the reverberation effect on the source identification method. The main objective of this paper is to identify noise source in the reverberant field. At fist, we try to identify noise sources in a rigid wall enclosure using the spherical beamforming method. In many case of practical interest, the wall has an admittance so that complex reflection process occurred. In this paper, we assumed the complex reverberant field in the enclosure to be the sum of plane waves with random incidence and magnitude. Then the effects of reverberant field at interior source identification have been studied theoretically as well as experimentally

  • PDF

Use of Rigid Scattering Body in the use of NAH based on the inverse BEM (역경계요소법에 근거한 근접 음향 홀로그래피에서 강체 산란체의 이용)

  • 김성일;정지훈;이정권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.486-489
    • /
    • 2004
  • The NAH based on the inverse BEM is used to reconstruct the source field, which is advantageous in dealing with the irregular source. In the implementation of this technique, a large number of pressure measurements is required because an over-determined pressure data set is required. These conditions accordingly cause the increase of measurement time and associated effort along with the error due to mal-positioning. The purpose of this study is to reduce such inconveniences: Instead of increasing the number of field pressure data, the number of transfer paths between the source and the receiver is increased by placing rigid scattering body in-between the source and receiver. For validating the usefulness and effectiveness of the method, the numerical analyses of interior problem are demonstrated. As a result, it is thought that the proposed method enables the measurement at smaller number of sensor positions and the monitoring of surface vibration with less experimental effects than before.

  • PDF

Heat Source Modeling of GMAW Considering Metal Transfer (용적이행을 고려한 GMA 용접의 열원 모델링)

  • 정기남;이지혜;이재영;유중돈
    • Journal of Welding and Joining
    • /
    • v.22 no.2
    • /
    • pp.69-77
    • /
    • 2004
  • The Gaussian heat source has been widely used to simulate the heat flux of the welding we, and applied to calculating the temperature distribution of a workpiece. The conventional two-dimensional Gaussian heat source for the GMAW is modified in this work by decomposing the arc heat into heats of the cathode and metal transfer. The efficiency and effective arc radius of each heat source are determined analytically for the free-flight mode such as the globular and spray modes. The temperature distribution and weld geometry are calculated using the finite element method, and distribution of the drop heat is found to have significant effects on the penetration. The predicted results show good agreements with the available experimental results, especially with the penetration.

The Sensitivity Analysis and Modeling for the Atmospheric Dispersion of Point Source (점오염원의 대기확산에 관한 민감도 분석과 모델링)

  • 이화운;원경미;배성정
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.57-64
    • /
    • 2000
  • The sensitivity analysis of two short-term models (ISCST3, INPUFF2.5) is performed to improve the model accuracy. It appears that the sensitivities on the changes of wind speed, stack height and stack inner diameter in the near distance from source, stability and mixing height in the remote distance form source, are significant. Also the gas exit velocity, stack inner diameter, gas temperature and air temperature which affect the plume rise have some effects on the concentration values of each model within the downwind distance where final plume rise is determined. And in modeling for the atmospheric dispersion of point pollutant source INPUFF2.5 can calculate amount, trajectory of puff and concentration versus time at each receptors. So, it is compatible to analyze distribution of point pollutants concentration at modeling area.

  • PDF

Analysis on the free surface flow induced by a pair of source-sink in Stokes flow (스톡스 유동장 내의 한 쌍의 소오스-싱크에 의한 자유표면 유동해석)

  • Jeong, Jae-Tack;Park, Jong-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.304-307
    • /
    • 2008
  • Two-dimensional Stokes flow due to the line source and line sink of same strength in semi-infinite flow region with free surface is analysed using complex variable theory and conformal mapping. Surface tension effects are included while gravity is neglected. From the results of analysis, flow pattern and free surface shape are obtained and velocity distribution on the free surface is determined with 2 independent parameters Ca (capillary number) and h (non-dimensionalized distance between source and sink). When the location of the sink is above the source, velocity on the free surface converges and a cusp occurs on the free surface for the value of Ca above some critical capillary number.

  • PDF

Analysis of Heat Source Distribution in Low Voltage Condenser (저압 콘덴서의 열원 분포 해석)

  • Kim, Jong-Gyeum;Lee, Dong-Ju;Kim, Il-Jung;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1242-1247
    • /
    • 2010
  • In this study, the heat source distributions at the end side and the center of the electrode are analyzed to estimate the electrical stress due to the harmonics from the nonlinear loads. The governing equation at the analysis area of low voltage condenser are numerically solved using the finite element software package to analyze the effects of heat source distribution due to the 5th and 7th harmonics, which can exist normally in the distribution network and can be applied to the low voltage condenser. Finally, the heat source distribution from the harmonics is compared and analyzed with the heat source distribution from the fundamental component of the applied voltage.

Effects of strong ground motions of near source earthquakes on response of thin-walled L-shaped steel bridge piers

  • Xie, Guanmo;Taniguchi, Takeo;Chouw, Nawawi
    • Structural Engineering and Mechanics
    • /
    • v.12 no.3
    • /
    • pp.341-346
    • /
    • 2001
  • Near source earthquakes can be characterized not only by strong horizontal but also by strong vertical ground motions with broad range of dominant frequencies. The inelastic horizontal response of thin-walled L-shaped steel bridge piers, which are popularly used as highway bridge supports, subjected to simultaneous horizontal and vertical ground excitations of near source earthquakes is investigated. A comprehensive damage index and an evolutionary-degrading hysteretic model are applied. Numerical analysis reveals that the strong vertical excitation of a near source earthquake exerts considerable influences on the damage development and horizontal response of thin-walled L-shaped steel bridge piers.

Optimal Thermal Design of a Single Heat Source in a Cavity (Cavity내의 단일 열원에 대한 최적 열적설계)

  • Yae, Y.T.;Choo, H.L.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.77-86
    • /
    • 1999
  • The optimal thermal design of a single heat source on one wall of a vertical open top cavity was studied experimentally. The temperature and flow fields in the cavity were visualized. The objectives of this study is to obtain the best location of the single heat source and to examine the effects of heat source protrusion, substrate thermal conductivity and cavity aspect ratio on the natural convection cooling due to a single heat source. As the results, the cooling effect for the copper substrate is superior to that of the epoxy-resin substrate and is improved with increasing cavity width. For the epoxy-resin substrate of lower conductivity, the protrusion of the heaters plays a role in decreasing the cooling effect. The best location was the mid-height of the substrate.

  • PDF

Basic Experimental Study on Room Lighting Effects using Artificial Light Source (인공 광원을 이용한 실내 조명 효과에 대한 기초 실험 연구)

  • Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.29-33
    • /
    • 2011
  • This study is performed to investigate the effect of the artificial light for room lightening. To do that, the experiments were done using the black room with 1m3 and performed to show the effect of the length between the room and light source and light intensities as LUX. The LUX of 18 sites in the room was measured using LUX meter. The length between the room and the light source was chosen as 500mm, 1000mm, and 1500mm and the light intensities was 3 levels. The results were shown the distinct difference between the part directly projected through the light path and non-directly projected. So, the light delivery path have to be modified for next step research. The results were very sensitive for the part directly projected through the light path. This study showed the basic results for room lightening using light source to simulate the solar lightening and was worth in a strict sense as fundamental study.

  • PDF