• Title/Summary/Keyword: sound absorption ratio

Search Result 50, Processing Time 0.033 seconds

A Study on the Sound Absorption Properties of Sound Absorption Block using by Artificial Light Weight Aggregate (인공경량골재를 이용한 철도 흡음블록의 흡음특성에 관한 연구)

  • Kang, Duck-Man;Seo, Jae-Won;Lee, In-Yong;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.830-839
    • /
    • 2008
  • This study is designed to manufacture the upgraded sound absorption concrete by using foamed concrete by using artificial light weight aggregate which raises the continuous void ratio to increase the sound absorption ratio and improve the strength. In manufacturing the sound absorption block, the pre-foaming form is applied to generate continuous voids, controlling the density by the addition of bubbles. It is general that the more porosity creates, the weaker strength becomes. Each of specimens are used for this experiment and measured their absorption ratio to examine the absorption property depending on frequency. As a results of experiment, it is evaluated that the absorption capacity of the sound absorption block has relation to compression strength and surface shape.

  • PDF

The effect of diffusers on the measurement of sound absorption in a reverberation room (잔향실법 흡음률 측정에 미치는 확산체의 영향)

  • Han, Hee-Kab;Kim, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

Sound Absorbing Characteristics of Porous Concrete according to Mixing Factor (배합요인에 따른 포러스 콘크리트의 흡음특성)

  • 이준;박승범;권혁준;김경훈;장영일;김형석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.489-492
    • /
    • 2003
  • The results of an experiment on the sound absorption of the porous concrete and its influence on the compressive strength are reported in this paper. Two different sizes of coarse aggregate of 5~13, 13~20mm, and the design void ratio of 20, 25 and 30 percent for a given size of aggregate were used. In the compressive strength, an aggregate of the size of 5~13mm is much higher strength than that of the 13~20mm, In the sound absorption experiment, the size of aggregate of 5~l0mm is much higher sound absorption than that of the 13~20mm. The sound absorption ratio was increased as the design void ratio. As a result, Porous concrete sufficiently have the performance of sound absorption.

  • PDF

A Study on the Sound Absorption Properties of Cellular Concrete with Continuous voids (연속공극을 갖는 기포콘크리트의 흡음특성에 관한 연구)

  • Lee, Seung-Han;Jung, Yong-Wook;Park, Jung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.566-573
    • /
    • 2003
  • This study was performed to manufacture a rigid sound absorbing material by increasing the continuous void ratio of cellular concrete, thereby achieving an increase in sound absorption ratio and an enhancement in strength of the cellular concrete. By the experiments, it was determined that an increase in sound absorption ratio is achieved by increasing the added amount of air voids, thereby increasing the continuous void ratio. When the material had a thickness of 5 cm, a satisfactory average sound absorption ratio of 70% was obtained at a continuous void ratio of 40% or more. An increase in the thickness of the sound absorbing material resulted in an increase in sound absorption ratio in a super bass range. The specific gravity of cellular concrete meeting an average sound absorption ratio of 70% was 0.4 at a material thickness of 5 cm, and 0.6 or less at a material thickness of 7 cm. The compressive strength of the cellular concrete having a specific gravity of 0.4 meeting an average sound absorption ratio of 70% or more was 1.37 Mpa at a cement fineness of 3,000. This compressive strength was increased to 3.34 MPa at a cement fineness of 8,000. Accordingly, it was determined that the compressive strength of cellular concrete having continuous voids increases with a higher cement fineness.

A Study on the Sound Absorption Properties of Foamed Concrete According to Dilution Ratio of Foaming Agent (기포제 희석비율에 따른 기포콘크리트의 흡음특성에 관한 연구)

  • Kang Ki-Woong;Kang Chul;Kim Ha-Seok;Kwag Eun-Gu;Kwon Ki-Joo;Kim Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.5-8
    • /
    • 2005
  • Sound absorbing performance is affected by porosity and continuity of void, therefore it is important to maintain stabilization of foam and to analyze properties of void pore in hardened state. The purpose of this study is to analyze the sound absorption properties and void characteristic of foamed concrete according to dilution ratio of foaming agent. The results of this experiment were as follows. It is determined that an increase in total and continuous void ratio is achieved by increasing of dilution ratio, and a shorter absorbing time was exhibited at a higher continuous void ratio. When the average void size of foamed concrete was below 1.5mm, the tendency of sound absorption coefficient compared with general sound absorber was appeared similarly.

  • PDF

Sound Absorbing Characteristics According to Interior Configuration of Noise Barrier (흡음형 방음벽의 내부 구성에 따른 흡음특성)

  • 박진규;김상헌;김관주;박희준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.387-392
    • /
    • 2003
  • This study is put a focus on the identification of sound characteristics according to the interior configuration of sound absorption material and air gap. Noise barrier is general consists of front perforated panel, air layer, sound absorption material, air gap and back plate. Noise barrier is required to the NRC value of 0.7. The absorbing performance of the noise barrier relies on the opening ratio of the perforated panel and the efficiency of the absorbing material. This study has observed the effect of opening ratio and hole size, the increase of sound absorbing performance by the configurations of sound absorption material and air gap. New designed noise barrier is achieved the acoustical performance of 0.87 the measurement in a reveration room.

  • PDF

Sound Absorbing Characteristics of Porous Concrete Using Recycled Aggregates (재생골재를 사용한 포러스 콘크리트의 흡음특성에 관한 연구)

  • 서대석;박승범;김정환;표구영;김범규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.485-488
    • /
    • 2003
  • The results of an experiment on the sound absorption of the porous concrete using recycled aggregates and its influence on the compressive strength are reported in this paper. The content of recycled aggregate of 0, 10, 30, 50 and 70%, and the design void ratio of 30 percent for a given size of aggregate were used. In the compressive strength, an aggregate of the size of 5~13mm is much higher strength than that of the 13~20mm, In sound absorption experiment, the sound absorption ratio was is subjected to decreased as the content of recycled aggregates was increased. As a result, Porous concrete using recycled aggregates and by-products sufficiently have the performance of sound absorption.

  • PDF

An Experimental Study on the Sound Absorption Property of a Sintered Clay Material (점토 소결재의 흡음특성에 관한 실험적 연구)

  • Yang, Yoon-Sang;Lee, Dong-Hoon;Seo, Eun-Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.365-371
    • /
    • 2013
  • The purpose of this study is to develop a sound absorbing material for indoor which manufactured by a clay and binding material. The seven kind of sound absorbing specimens which sintered through a mold process at high temperature were manufactured for the purpose of testing sound absorption performance. The random and normal sound absorption coefficients were measured for the sintered clay sound absorbing specimens with different particle size, density and mixture ratio. From the experimental results, it was found that its particle size was closely related to the sound absorption performance. It was shown that the sintered clay sound absorbing specimen had the sound absorption properties of a fiber-type or a resonance-type sound absorbing material depending on the particle size.

The Study on Sound Absorbing Characteristics of Porous Concrete according to Reverberation Room Methods (랜덤입사방법에 의한 포러스 콘크리트의 흡음특성에 관한 실험적 연구)

  • Seo Dae seuk;Park Seong Bum;Cho Gwang yeon;Jang Young Ill;Kim Hyung Seok;Lee yoon Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.568-571
    • /
    • 2004
  • This research estimated the physical. mechanical characteristic and the character of sound absorption according to target void ratio of porous concrete and the mixing ratio of recycled aggregate for the valid utilization of recycled aggregate using waste concrete and sound reduction out of a road, a railway, a residential street, and a downtown area. As a result of the test, compressive strength tended to be a radical strength fall when target void ratio was $25\%$ and contents of recycled aggregate exceeded over $50\%$. Also, the character of sound absorption of porous concrete which used recycled aggregate using waste concrete was the most excellent when target void ratio was $25\%$, and the influence by contents of recycled aggregate was trivial. Therefore, when the strength and the character of sound absorption of porous concrete are considered, it is proved valid that proper target void ratio was $25\%$ and contents of recycled aggregate using waste concrete was $50\%$ or so.

  • PDF

Sound absorption of micro-perforated elastic plates in a cylindrical impedance tube (원통형 임피던스 튜브 내 미세천공 탄성 판의 흡음)

  • Kim, Hyun-Sil;Kim, Bong-Ki;Kim, Sang-Ryul;Lee, Seong-Hyun;Ma, Pyung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.181-187
    • /
    • 2018
  • In this paper, sound absorption of micro-perforated elastic plates installed in an impedance tube of a circular cross-section is discussed using an analytic method. Vibration of the plates and sound pressure fields inside the duct are expressed in terms of an infinite series of modal functions, where modal functions in the radial direction is given in terms of the Bessel functions. Under the plane wave assumption, a low frequency approximation is derived by including the first few plate modes, and the sound absorption coefficient is given in terms of an equivalent impedance of a single surface. The sound absorption coefficient using the proposed formula is in excellent agreement with the result by the FEM (Finite Element Method), and shows dips and peaks at the natural frequencies of the plate. When the perforation ratio is very small, the sound absorption coefficient is dominated by the vibration effect. However, when the perforation ratio reaches a certain value, the sound absorption is mainly governed by the rigid MPP (Micro-Perforated Plate), while the vibration effect becomes very small.