• Title/Summary/Keyword: sound /w/

Search Result 282, Processing Time 0.025 seconds

Sound Absorption Performance of Noise Barrier According to Single Number Rating Methods (단일수치 평가방법에 따른 방음벽의 흡음성능 고찰)

  • Kim, Yonghee;Lee, Sungchan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.243-250
    • /
    • 2017
  • In this study, single number rating methods of sound absorption coefficients are discussed. After that the sound absorption performance of noise barriers which are classified by Korea Standard are analyzed according to several standards. The existing rating methods such as NRC (noise reduction coefficient), SAA (sound absorption average) or ${\alpha}_w$ (weighted sound absorption coefficient) from ASTM C423, KS F 3505 and ISO 11654 are introduced. The sound absorption performance of noise barrier is evaluated to compare NRC and ${\alpha}_w$ value. When the value is over 0.6 there are large variance between NRC and ${\alpha}_w$ value. As results, it is needed to unify single number rating methods of sound absorption coefficients for Korean standards on sound absorbing materials.

Sound velocity effect on vibrating gas densimeter (음속이 진동형 기체 밀도 측정기에 미치는 영향)

  • Lee, W.G.;J.W. Chung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.28-33
    • /
    • 1993
  • Measurements errors due to sound velocity effect on vibrating gas densimeters were described. Nitrogen was used to calibrate the densimeter, and oxygen was employed to determine a coefficient for the compensation of sound velocity effect. Sound velocity effects were shown with methane at temperatures of 7.97, 19.93 and 39.57 .deg. C, and pressures up to 3.6 Mpa. A relative error of about 1% was introduced when the nitrogen calibrated densimeter was used to measure densities of pure methane. A method of sound velocity effect compensation was able to reduce the error down to 0.1%.

  • PDF

Field Test and Evaluation of Wind Turbine Noise according to IEC Standards (IEC 규격에 따른 풍력 터빈 소음의 현장 실증)

  • Cheong, Cheol-Ung;Jung, Sung-Su;Cheung, Wan-Sup;Shin, Soo-Hyun;Chun, Se-Jong;Lee, Sang-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Acoustic Characteristic of Emergency Broadcasting Speakers (비상방송용 스피커의 음향 특성 비교)

  • Jeong, Jeong-Ho;Seo, Bo-Youl;Park, Kye-Won;Shin, Yi-Chul;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • In this study, the acoustic characteristics of 13 types of emergency broadcasting speakers were tested under the test set-up of UL 2043 and compared. When the sound pressure level of 1 W speakers was compared with speakers with a 15 W output, the SPL of the 15 W speakers was approximately 20 dB higher in some frequency bands. Loudness analysis showed that people can recognize emergency sound from a 15 W speaker twice as loud as the emergency sound from 1 W speakers. The analysis results on the articulation index (room) had an opposite tendency with loudness results, meaning that small speakers can generate clearer sound. Therefore, it is necessary to improve emergency broadcasting speakers to generate louder and clearer sound. Moreover, a performance evaluation standard is needed based on the reasonable and quantitative measurements and evaluations of the acoustic characteristics of the emergency-broadcasting speakers so that a sufficient and clear sound can be generated in various spaces. In addition, it is necessary to establish standards for the clarity of emergency broadcasting in various spaces.

A Study on Noise Automatic Inspection System for Washing Machine Auto-Transmission (세탁기용 자동변속기 (Auto-Transmission)의 이상음 검사자동화 시스템에 관한 연구)

  • 김재열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.310-315
    • /
    • 1998
  • This study includes noise automatic inspection system for washing machine auto-transmission one of modern home necessary. We effort to find and certificate sound noisesource by sound power and sound intensity, and apply to frequency analysis in vibration related sound noise. Still more we have been studying to data acquisition and programming for MS VisualBasic version 5.0. System component is below. 1) Pentium PC for data acquisition. 2) DSO for noise acquisition. 3) S/W for comparison and decision. 4) I/F Board for data communication. Wave form data through the DSO are converting to ASCII code data. The ASCII code through binary converting S/W are to be decision fitness or the badness comparison S/W. Finally, we will making noise monitoring system and automatic inspection system.

  • PDF

Improvement and Change of Acoustic Performance of University Small Hall Remodeled as Exclusive for Lecture Room : Based on the case of the W University (강의전용 공간으로 리모델링된 대학 소공연장의 음향성능 개선 및 변화 : W대학의 사례를 바탕으로)

  • Kim, Min-Ju;Kim, Jae-Soo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.19 no.2
    • /
    • pp.21-31
    • /
    • 2020
  • The purpose of this study was to analyze the contents of the sound environment among the various environmental factors that directly or indirectly affect the quality of education through the remodeling of the small hall of the College of Humanities at W University. Before remodeling into a lecture room, the small hall of the College of Humanities at W University, which is the subject of this study, was designed to create an indoor sound environment suitable for a lecture room by recognizing differences in acoustic performance between the performance halls that require adequate sound quality and the lecture rooms where the clarity of voice is important. Therefore, this study aimed to present examples of improved acoustic performance in lecture rooms by remodeling through the stages of measuring acoustic performance before remodeling, presentation of a change in finishing materials through sound simulation, and measurement of sound performance after remodeling. It is expected that this process can be used as an example of securing indoor acoustic performance suitable for educational space, such as lecture rooms, by changing the finishing materials.

Preliminary Design and Implementation of 3D Sound Play Interface for Graphic Contents Developer (그래픽 콘텐츠 개발자를 위한 입체음 재생 인터페이스 기본 설계 및 구현)

  • Won, Yong-Tae;Jang, Bong-Seog;Ahn, Dong-Soon;Kwak, Hoon-Sung
    • Journal of Digital Contents Society
    • /
    • v.9 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Due to the advance of H/W and S/W techniques to play 3D sound, the virtual space contented by 3D graphics and sounds can provide users more improved realities and vividness. However for the small 3D contents developers and companies, it is hard to implement 3D sound techniques because the implementation requires expensive sound engines, 3D sound technical understanding and 3D sound programming skills. Therefore 3D-sound-playing-interface is necessary to easy and cost-effective 3D sound implementation. Using this interface, graphics experts can easily add 3D sound techniques to their applications. In this paper, the followings are designed and implemented as a preliminary stage in the way of developing the 3D sound playing interface. First, we develop 3D sound S/W modules converting mono to 3D sound in PC based systems. Second, we develop the interconnection modules to map 3D graphic objects and sound sources. The developed modules in this paper can allow the user to percept sound source position and surround effect at the moving positions in the virtual world. In the coming works, we are going to develop the more completed 3D sound playing interface consisted of the synchronization technique for sound and moving objects, and HRTF.

  • PDF

Analysis of sound power level of high-noise construction machinery excavator (고소음 건설기계 굴삭기의 소음도 현황 분석)

  • Park, Hyung-Kyu;Jung, Joon Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.240-246
    • /
    • 2019
  • The noise generated by construction machinery operating at construction sites is a major cause of environmental disputes with nearby residents. To reduce construction site noise, low noise construction machinery and low noise methods are recommended to be used first. In addition, the possible noise should be predicted and preventive measures suitable for the noise source should be taken. This study analyzed the sound power level of an excavator, which is used most frequently at construction sites. The sound power level of 297 excavators sold in Korea after 2008 were analyzed and the sound power level was classified according to the type, output (kW), and production site of the excavator engine based on the measured data. As a result, the sound power level decreased by 1 dBA depending on the change in engine type and the sound power level increased by approximately 3 dB (A) when the engine output was doubled. In addition, the sound power level was low in small-sized products of less than 55 kW for overseas products and medium and small-sized products of 55 to 104 kW for domestic products.