• Title/Summary/Keyword: solution measure

Search Result 904, Processing Time 0.031 seconds

HYPERSURFACES WITH PRESCRIBED MEAN CURVATURE IN MEASURE METRIC SPACE

  • Zhengmao Chen
    • Bulletin of the Korean Mathematical Society
    • /
    • v.60 no.4
    • /
    • pp.1085-1100
    • /
    • 2023
  • For any given function f, we focus on the so-called prescribed mean curvature problem for the measure e-f(|x|2)dx provided thate-f(|x|2) ∈ L1(ℝn+1). More precisely, we prove that there exists a smooth hypersurface M whose metric is ds2 = dρ2 + ρ2d𝜉2 and whose mean curvature function is ${\frac{1}{n}}(\frac{u^p}{{\rho}^{\beta}})e^{f({\rho}^2)}{\psi}(\xi)$ for any given real constants p, β and functions f and ψ where u and ρ are the support function and radial function of M, respectively. Equivalently, we get the existence of a smooth solution to the following quasilinear equation on the unit sphere 𝕊n, $${\sum_{i,j}}({{\delta}_{ij}-{\frac{{\rho}_i{\rho}_j}{{\rho}^2+|{\nabla}{\rho}|^2}})(-{\rho}ji+{\frac{2}{{\rho}}}{\rho}j{\rho}i+{\rho}{\delta}_{ji})={\psi}{\frac{{\rho}^{2p+2-n-{\beta}}e^{f({\rho}^2)}}{({\rho}^2+|{\nabla}{\rho}|^2)^{\frac{p}{2}}}}$$ under some conditions. Our proof is based on the powerful method of continuity. In particular, if we take $f(t)={\frac{t}{2}}$, this may be prescribed mean curvature problem in Gauss measure space and it can be seen as an embedded result in Gauss measure space which will be needed in our forthcoming papers on the differential geometric analysis in Gauss measure space, such as Gauss-Bonnet-Chern theorem and its application on positive mass theorem and the Steiner-Weyl type formula, the Plateau problem and so on.

Stability Evaluation on Measuring Water-soluble Chloride Anions from Iron Artifacts (철제유물의 수용성 염소이온 측정방법에 대한 안정성 평가)

  • Lee, Jae-Sung;Park, Hyung-Ho;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.397-406
    • /
    • 2010
  • The most ideal method to measure the water-soluble $Cl^-$ ion eluted from iron artifacts is conducting the analysis on desalting solution by Ion Chromatography. But most institutes related to cultural heritages use Cl meter by reason of lack of budget and experts. This study evaluated reliability and stability between Cl meter and Ion Chromatography by doing cross-validation with results from two methods to detect $Cl^-$ ion of desalting solution. From D.I water, extremely small quantities of $Cl^-$ ion was detected by the influence of remaining water-soluble $Cl^-$ ion at the electrode of Cl meter and water-soluble $Cl^-$ which remains in Sodium sesquicarbonate, components of reagent was detected as well. The first desalting solution had the most $Cl^-$ ions, $Cl^-$ ion slightly decreased from the second to the fourth desalting solution and tend to decrease again at the stage of dealkalified in D.I water. Each Cl meter has the standard deviation according to the measured numbers and the higher concentration of $Cl^-$ ion the desalting solution has, the wider the deviation is. But when the concentration of $Cl^-$ ion is low, it was stable to use Cl meter to detect the concentration of $Cl^-$ ion from iron artifacts because there is the small deviation, It is thought that conductivity meter method is not suitable for measuring $Cl^-$ ion, because the electrical conductivity of alkaline solution is too high to measure $Cl^-$ ion.

In-Situ Optical Monitoring of Electrochemical Copper Deposition Process for Semiconductor Interconnection Technology

  • Hong, Sang-Jeen;Wang, Li;Seo, Dong-Sun;Yoon, Tae-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.78-84
    • /
    • 2012
  • An in-situ optical monitoring method for real-time process monitoring of electrochemical copper deposition (CED) is presented. Process variables to be controlled in achieving desired process results are numerous in the CED process, and the importance of the chemical bath conditions cannot be overemphasized for a successful process. Conventional monitoring of the chemical solution for CED relies on the pH value of the solution, electrical voltage level for the reduction of metal cations, and gravity measurement by immersing sensors into a plating bath. We propose a nonintrusive optical monitoring technique using three types of optical sensors such as chromatic sensors and UV/VIS spectroscopy sensors as potential candidates as a feasible optical monitoring method. By monitoring the color of the plating solution in the bath, we revealed that optically acquired information is strongly related to the thickness of the deposited copper on the wafers, and that the chromatic information is inversely proportional to the ratio of $Cu$ (111) and {$Cu$ (111)+$Cu$ (200)}, which can used to measure the quality of the chemical solution for electrochemical copper deposition in advanced interconnection technology.

A Leakage-Based Solution for Interference Alignment in MIMO Interference Channel Networks

  • Shrestha, Robin;Bae, Insan;Kim, Jae Moung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.2
    • /
    • pp.424-442
    • /
    • 2014
  • Most recent research on iterative solutions for interference alignment (IA) presents solutions assuming channel reciprocity based on the suppression of interference from undesired sources by using an appropriate decoding matrix also known as a receiver combining matrix for multiple input multiple output (MIMO) interference channel networks and reciprocal networks. In this paper, we present an alternative solution for IA by designing precoding and decoding matrices based on the concept of signal leakage (the measure of signal power that leaks to unintended users) on each transmit side. We propose an iterative algorithm for an IA solution based on maximization of the signal-to-leakage-and-noise ratio (SLNR) of the transmitted signal from each transmitter. In order to make an algorithm removing the requirement of channel reciprocity, we deploy maximization of the signal-to-interference-and-noise ratio (SINR) in the design of the decoding matrices. We show through simulation that minimizing the leakage in each transmission can help achieve enhanced performance in terms of aggregate sum capacity in the system.

A Modified Back-Titration Method to Measure Soil Titration Curves Minimizing Exchange Acidity and Dilution Effects (토양 적정곡선 측정을 위하여 교환산도와 희석효과를 최소화한 수정역적정법 제안)

  • Jozefaciuk, G.;Shin, Jae Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.321-327
    • /
    • 1996
  • A back titration method was suggested to determine the exchangeable acidity of soil originated from exchangeable aluminum and adsorbed hydrogen ion in relation to minimizing its titration error. In this method. soils are treated by neutral salt solution whose concentration is the same as soil solution suspended by distilled water. And then. its pH is adjusted at 3, using 1 N HCl solution and back-titrated by 0.1 N NaOH solution containing 1 N NaCl. The results of the suggested back-titration showed the possibility of practical application with linear relationship to that of standard method.

  • PDF

Experimental Investigation on the Drag Reduction for an Axi-symmetric Body by Micro-bubble and Polymer Solution

  • Yoon, Hyun-Se;Park, Young-Ha;Van, Suak-Ho;Kim, Hyung-Tae;Kim, Wu-Joan
    • Journal of Ship and Ocean Technology
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Experiments on friction drag reduction by injecting polymer (Polyethylene oxide) solution or micro-bubbles were carried out in the cavitation tunnel of KRISO. Two different drag reduction mechanisms were applied to a slender axi-symmetric body to measure the total drag reduction. And then the amount of friction drag reduction was estimated under the assumption that the reduction mechanisms were effective only to the friction drag component. As the result of the tests, polymer solution drag reduction up to 23% of the total drag was observed and it corresponds to about 35% of the estimated friction drag of the axi-symmetric body. This result matched reasonably well to that of the flat plate test "(Kim et al, 2003)". The normalization of the controlling parameters was tried at the end of this paper. Micro-bubble drag reduction was within 1% of its total drag. This unexpected result was quite different from that of the flat plate case "(Kim et at, 2003)" The possible reasons were discussed in this paper.

Electrochemical Determination of Glucose Concentration Contained in Salt Solution (소금용액에 포함된 글루코오스 농도의 전기화학적 측정)

  • 김영한
    • Journal of Korean Port Research
    • /
    • v.14 no.4
    • /
    • pp.475-479
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the determination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a quartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution, and a proper relation between the concentrations of glucose solution, and a proper relation between the concentration and the measurements is analyzed. As a result, it is found that a linear relation between the concentration of less than 900 ppm and the peak current when a constant potential of -180 mV (SSCE) is applied. The relation can be utilized for the determination of glucose concentration in sea water, and considering a direct relation between gluose concentration and chemical oxygen demand tells a possibility of the measurement of chemical oxygen demand using quartz crystal oscillators.

  • PDF

Inhibitory Effects of Gaejibokryunghwan on Cell Proliferation in HeLa Cells (계지복령환(桂枝茯笭丸)의 HeLa Cell 증식억제(增殖抑制)와 사멸효과(死滅效果))

  • Hwang Deok-Sang;Cho Jung-Hoon;Jang Jun-Bock;Lee Kyung-Sub
    • The Journal of Korean Medicine
    • /
    • v.27 no.1 s.65
    • /
    • pp.23-35
    • /
    • 2006
  • Objectives : This study was conducted to investigate the inhibitory effects of Gaejibokryunghwan on cell proliferation in HeLa cells. Methods : Human uterine cervical carcinoma HeLa cells were cultured in the 1%, 5% and 10% concentration of Gaejibokryunghwan extract solution. All three were cultured for 24 hours, 48 hours and 72 hours each, to examine the inhibitory effects of Gaejibokryunghwan. Afterwards, we drew out the effect of Gaejibokryunghwan extract solution by making 5 analysis. First analysis was to measure the proliferation rate of cells. Second was FACS analysis. Third was to estimate the activity or caspase-3. Fourth, we used XTT assay to analyze the activation or cells. Ana lastly, a molecular biological method was used to determine activation of MAP kinase in the HeLa cells. Results : After 24, 48 and 72 hours cultivation, the proliferation of HeLa cells showed the dose-dependent decrease in all Gaejibokryunghwan extract solution groups compared to the control group. In the FACS analysis, Gaejibokryunghwan extract solution groups showed increased caspase expression compared to the control group, except for the group for 48 and 72 hours in 1 % concentrate. Caspase-3 activities were increased in all, except tile group cultured for 24 hours in 5% concentrate and the groups cultured for 48 hours in 1% and 5% concentrate. In the XTT study, 1% Gaejibokryunghwan extract solution groups showed increase compared to the control group, but other Gaejibokryunghwan extract solution containing groups showed significant decrease compared to the control after 24, 48 and 72 hours of cultivation. The expressions of MAP kinase were decreased in all Gaejibokryunghwan extract solution containing groups compared to the control group after 24, 48 and 72 hours of cultivation. Conclusions : From this study, we could suggest that Gaejibokryunghwan be available to the inhibition of proliferation of human cervical carcinoma cell line, HeLa cells in vitro.

  • PDF

Moving obstacle avoidance of a robot using avoidability measure (충돌 회피 가능도를 이용한 로봇의 이동 장애물 회피)

  • Ko, Nak-Yong;Lee, Beom-Hee
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.2
    • /
    • pp.169-178
    • /
    • 1997
  • This paper presents a new solution approach to moving obstacle avoidance problem of a robot. A new concept, avoidability measure(AVM) is defined to describe the state of a pair of a robot and an obstacle regarding the collision between them. As an AVM, virtual distance function(VDF) is derived as a function of three state variables: the distance from the obstacle to the robot, outward speed of the obstacle relative to the robot, and outward speed of the robot relative to the obstacle. By keeping the virtual distance above some positive limit value, the robot avoids the obstacle. In terms of the VDF, an artificial potential is constructed to repel the robot away from the obstacle and to attract the robot toward a goal location. At every sampling time, the artificial potential field is updated and the force driving the robot is derived from the gradient of the artificial potential field. The suggested algorithm drives the robot to avoid a moving obstacle in real time. Since the algorithm considers the mobility of the obstacle and robot as well as the distance, it is effective for moving obstacle avoidance. Some simulation studies show the effectiveness of the proposed approach.

  • PDF

A Study on the Actual Conditions of the Information Promotion Policies for SMB Enterprises in Busan (중소기업 정보화 지원 시책에 대한 실태분석 - 부산지역을 중심으로 -)

  • Kim, Do-Geun
    • Journal of Digital Contents Society
    • /
    • v.8 no.2
    • /
    • pp.213-225
    • /
    • 2007
  • This study confirms Busan area medium and small enterprises' position and analyzed present condition and actual conditions of swing Korea measure and consumer's attitude about measure in general circumstance that our country medium and small enterprises is placed in information. According to result that analyze Busan area medium and small enterprises' information level, Busan was expose by whole country average low including the electron commercial transaction rate. When consider weight that Busan economy occupies in gross domestic product, information differential of medium and small enterprises of Busan area is subject that must improve urgently and seriousness point is true that information differential of manufacturing industry is main factor more. Therefore, urgent agenda should be the activation of manufacturing industry information assistance measure and extension of current manufacturing technique information assistance business for Busan economy. Also, at problem solution progress, Busan is thought that must come looking for seat role actively.

  • PDF