• 제목/요약/키워드: solution deposition method

검색결과 287건 처리시간 0.09초

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권11호
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

Structural, morphological, optical, and photosensing properties of Cs2TeI6 thin film synthesized by two-step dry process

  • Hoat, Phung Dinh;Van Khoe, Vo;Bae, Sung-Hoon;Lim, Hyo-Jun;Hung, Pham Tien;Heo, Young-Woo
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.279-285
    • /
    • 2021
  • Recently, cesium tellurium iodine (Cs2TeI6) has emerged as an inorganic halide perovskite material with potential application in optoelectronic devices due to its high absorption coefficient, suitable bandgap and because it consists of nontoxic and earth-abundant elements. However, studies on its fabrication process as well as photoresponse characteristics are limited. In this study, a simple and effective method is introduced for the synthesis of Cs2TeI6 thin films by a two-step dry process. A Cs2TeI6-based lateral photosensor was fabricated, and its photoresponse characteristics were explored under laser illuminations of four different wavelengths in the visible range: 405, 450, 520, and 655 nm. The initial photosensing results suggest potential application and can lead to more promising studies of Cs2TeI6 film in optoelectronics.

정전분무증착법에 의한 중온형 고체산화물 연료전지를 위한 Sm0.5Sr0.5CoO3 양극막의 제조 (Fabrication of Sm0.5Sr0.5CoO3 cathode films for intermediate temperature SOFCs by electrostatic spray deposition)

  • 박인유;임종모;정영글;신동욱
    • 한국결정성장학회지
    • /
    • 제20권2호
    • /
    • pp.69-73
    • /
    • 2010
  • 정전분무증착 기술에 의해 증착된 고체산화물 연료전지(SOFC) 양극재료인 SSC 양극막의 미세구조적 변화에 대해 연구하였다. Samarium chloride hexahydrate$(SmCl_3{\cdot}6H_2O)$, strontium chloride hexahydrate$(Co(No_3)_2{\cdot}6H_2O)$, cobalt nitrate hexahydrate$(Co(No_3)_2{\cdot}6H_2O)$의 출발 물질과 용매로써 메탄올이 전구체 용액을 제조하는데 사용되었다. SOFC의 양극을 위해 적합한 다공성의 SSC 막을 제조하였으며, 그 미세구조가 증착시간, 기판온도, 인가전압 등과 같은 공정변수들에 의존한다는 것을 관찰하였다. 주사전자현미경과 X-ray 회절 패턴이 미세구조와 결정성 분석을 위해 사용되었다. 본 연구를 통해, ESD 기술이 요구하는 상의 합성과 다공성의 미세구조를 갖는 SOFC의 양극막을 제조하는데 효과적인 방법임을 입증하였다.

IBC형 태양전지 제작을 위한 p-a-Si:H 증착층의 파이버 레이저 가공에 관한 연구 (Study on Fiber Laser Annealing of p-a-Si:H Deposition Layer for the Fabrication of Interdigitated Back Contact Solar Cells)

  • 김성철;이영석;한규민;문인용;권태영;경도현;김영국;허종규;윤기찬;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.430-430
    • /
    • 2008
  • Using multi plasma enhanced chemical vapor deposition system (Multi-PECVD), p-a-Si:H deposition layer as a $p^+$ region which was annealed by laser (Q-switched fiber laser, $\lambda$ = 1064 nm) on an n-type single crystalline Si (100) plane circle wafer was prepared as new doping method for single crystalline interdigitated back contact (IBC) solar cells. As lots of earlier studies implemented, most cases dealt with the excimer (excited dimer) laserannealing or crystallization of boron with the ultraviolet wavelength range and $10^{-9}$ sec pulse duration. In this study, the Q-switched fiber laser which has higher power, longer wavelength of infrared range ($\lambda$ = 1064 nm) and longer pulse duration of $10^{-8}$ sec than excimer laser was introduced for uniformly deposited p-a-Si:H layer to be annealed and to make sheet resistance expectable as an important process for IBC solar cell $p^+$ layer on a polished n-type Si circle wafer. A $525{\mu}m$ thick n-type Si semiconductor circle wafer of (100) plane which was dipped in a buffered hydrofluoric acid solution for 30 seconds was mounted on the Multi-PECVD system for p-a-Si:H deposition layer with the ratio of $SiH_4:H_2:B_2H_6$ = 30:120:30, at $200^{\circ}C$, 50 W power, 0.2 Torr pressure for 20 minutes. 15 mm $\times$ 15 mm size laser cut samples were annealed by fiber laser with different sets of power levels and frequencies. By comparing the results of lifetime measurement and sheet resistance relation, the laser condition set of 50 mm/s of mark speed, 160 kHz of period, 21 % of power level with continuous wave mode of scanner lens showed the features of small difference of lifetime and lowering sheet resistance than before the fiber laser treatment with not much surface damages. Diode level device was made to confirm these experimental results by measuring C-V, I-V characteristics. Uniform and expectable boron doped layer can play an important role to predict the efficiency during the fabricating process of IBC solar cells.

  • PDF

Corrosion Behavior of Si,Zn and Mn-doped Hydroxyapatite on the PEO-treated Surface

  • Park, Min-Gyu;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.78-78
    • /
    • 2017
  • Pure Titanium and alloy have been widely used in dental implants and orthopedics due to their excellent mechanical properties, biocompatibility and corrosion resistance. However, due to the biologically inactive nature of Ti metal implants, it cannot bind to the living bone immediately after transplantation into the body. In order to improve the bone bonding ability of titanium implants, many attempts have been made to alter the structure, composition and chemical properties of titanium surfaces, including the deposition of bioactive coatings. The PEO method has the advantages of short experiment time and low cost. These advantages have attracted attention recently. Recently, many metal ions such as silicon, magnesium, zinc, strontium, and manganese have received attention in this field due to their impact on bone regeneration. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation and promotes bone metabolism and growth. Manganese (Mn) is an essential trace metal found in all tissues and is required for normal amino acid, lipid, protein and carbohydrate metabolism. The objective of this work was research on the corrosion behavior of Si, Zn and Mn-doped hydroxyapatite on the PEO-treated surface. Anodized alloys was prepared at 270V~300V voltage in the solution containig Zn, Si, and Mn ions. Ion release test was carried out using potentidynamic and AC impedance method in 0.9% NaCl solution. The surface characteristics of PEO treated Ti-6Al-4V alloy were investigated using XRD, FE-SEM, AFM and EDS.

  • PDF

Invention of Ultralow - n SiO2 Thin Films

  • Dung, Mai Xuan;Lee, June-Key;Soun, Woo-Sik;Jeong, Hyun-Dam
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.281-281
    • /
    • 2010
  • Very low refractive index (<1.4) materials have been proved to be the key factor improving the performance of various optical components, such as reflectors, filters, photonic crystals, LEDs, and solar cell. Highly porous SiO2 are logically designed for ultralow refractive index materials because of the direct relation between porosity and index of refraction. Among them, ordered macroporous SiO2 is of potential material since their theoretically low refractive index ~1.10. However, in the conventional synthesis of ordered macroporous SiO2, the time required for the crystallization of organic nanoparticles, such as polystyrene (PS), from colloidal solution into well ordered template is typical long (several days for 1 cm substrate) due to the low interaction between particles and particle - substrate. In this study, polystyrene - polyacrylic acid (PS-AA) nanoparticles synthesized by miniemulsion polymerization method have hydrophilic polyacrylic acid tails on the surface of particles which increase the interaction between particle and with substrate giving rise to the formation of PS-AA film by simply spin - coating method. Less ordered with controlled thickness films of PS-AA on silicon wafer were successfully fabricated by changing the spinning speed or concentration of colloidal solution, as confirmed by FE-SEM. Based on these template films, a series of macroporous SiO2 films whose thicknesses varied from 300nm to ~1000nm were fabricated either by conventional sol - gel infiltration or gas phase deposition followed by thermal removal of organic template. Formations of SiO2 films consist of interconnected air balls with size ~100 nm were confirmed by FE-SEM and TEM. These highly porous SiO2 show very low refractive indices (<1.18) over a wide range of wavelength (from 200 to 1000nm) as shown by SE measurement. Refraction indices of SiO2 films at 633nm reported here are of ~1.10 which, to our best knowledge, are among the lowest values having been announced.

  • PDF

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

흡착벗김 전압-전류법을 이용한 부신피질 호르몬의 분석 (Adsorption Striping Voltammetric Analysis of Corticosteroid Hormones)

  • 김일광;천현자;정승일;박정환
    • 분석과학
    • /
    • 제7권2호
    • /
    • pp.141-147
    • /
    • 1994
  • $1.0{\times}10^{-2}M$ 수산화나트륨을 지지전해질로 하여 흡착벗김 전압-전압법으로 부신피질 호르몬을 분석하였다. 분석 최적 조건은 흡착시간 360초, 흡착전위 -0.80 volts, 수은방울 크기 medium, 주사속도 20mV/sec였으며 검량선은 $5.0{\times}10^{-9}M$에서 $8.0{\times}10^{-7}M$ 범위까지 좋은 직선성을 보여 주었다. 검출한계는 $9.5{\times}10^{-10}M$이었다. 또한 이 방법을 의약품의 부신피질 호르몬 분석에 응용한 결과, 다른 첨가제의 방해 없이 분리분석이 가능하였다.

  • PDF

의약물 중 성호르몬의 흡착벗김 전압-전류법 정량 (Adsorptive Stripping Voltammetric Determination of Sex Hormones in Medicines)

  • 김일광;천현자;장경선
    • 분석과학
    • /
    • 제7권2호
    • /
    • pp.133-140
    • /
    • 1994
  • $1.0{\times}10^{-2}M$ 수산화나트륨을 지지전해질로 하여 흡착벗김 전압-전류법으로 성호르몬의 분석을 흡착시간 240초, 흡착전위 -0.80 volts, 수은방울 크기 medium, 주사속도 20mV/sec의 조건에서 실시하였다. 검량선은 $5.0{\times}10^{-9}M$에서 $8.0{\times}10^{-7}M$ 범위까지 직선성을 보여 주었다. 검출한계는 progesterone이 $8.0{\times}10^{-10}M$이고 testosterone propionate는 $1.4{\times}10^{-9}M$이었다. 또한 이 방법을 의약물의 성호르몬 분석에 응용한 결과, 다른 첨가제의 방해 없이 분리분석이 가능하였다.

  • PDF

네모파 산화전극 벗김 전압전류법을 이용한 게르마늄의 미량분석 (Determination of Trace Level Germanium(IV) by Square Wave Anodic Stripping Voltammetry)

  • 김일광;천현자;정승일;박성우;유재훈
    • 대한화학회지
    • /
    • 제37권11호
    • /
    • pp.943-950
    • /
    • 1993
  • 8.0 ${\times}\;10^{-2}$ M catechol이 들어있는 5.0 ${\times}\;10^{-2}$ M 과염소산 지지전해질 용액속에서 네모파 산하전극벗김 전압전류법으로 게르마늄의 미량분석을 조사하였다. ppb 수준의 분석에서는 석출시간 120초, 석출전위 -0.9 volts, 주파수 100Hz일 때 가장 적합하였다. 구리와 납, 실리콘 같은 금속이온이 상당량 존재하여도 공존이온이 영향을 받지 않고 게르마늄의 분석이 가능하였다. 검량선은 0.40 ppb 에서 2.0 ppm 범위까지 양호한 직선성을 보였으며, 검출한계는 0.080 ppb 이였다. 이 방법은 분석시간이 짧고 감도가 좋기 때문에 미량 게르마늄 분석에 유용하였다

  • PDF