• 제목/요약/키워드: solar wind

검색결과 1,072건 처리시간 0.032초

New DTR Estimation Method Without Measured Solar and Wind Data

  • Ying, Zhan-Feng;Chen, Yuan-Sheng;Feng, Kai
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.576-585
    • /
    • 2017
  • Dynamic thermal rating (DTR) of overhead transmission lines can provide a significant increase in transmission capacity compared to the static thermal rating. However, the DTR are usually estimated by the traditional thermal model of overhead conductor that is highly dependent on the solar, wind speed and wind direction data. Consequently, the estimated DTR would be unreliable and the safety of transmission lines would be reduced when the solar and wind sensors are out of function. To address this issue, this study proposed a novel thermal model of overhead conductor based on the thermal-electric analogy theory and Markov chain. Using this thermal model, the random variation of conductor temperature can be simulated with any specific current level and ambient temperature, even if the solar and wind sensors are out of function or uninstalled. On this basis, an estimation method was proposed to determine the DTR in the form of probability. The laboratory experiments prove that the proposed method can estimate the DTR reliably without measured solar and wind data.

풍력 및 태양광 에너지의 복합발전 시스템 (Composition Generation Systems of Wind and Solar Power)

  • 김신효;김재준;배철오;김현수;엄한성;안병원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.187-190
    • /
    • 2005
  • ${\cdot}$재생에너지라고 불리는 대체에너지는 무공해, 무한정의 다양한 자연에너지의 특성과 이용기술을 활용하여 화석연료를 사용하는 기존에너지를 대체하는 에너지이다. 이에 따라 본 연구에서는 태양광 발전과 풍력발전의 에너지 발생 현황을 살펴보고 목포해안지역에 풍속, 풍향, 계절 등의 기상조건의 변화에 따른 데이터를 분석하여 목포해안지역에서 경제적이고 효율적인 복합발전시스템의 적용 가능성을 제안해 보고자 한다.

  • PDF

Development of LED Street Lighting Controller for Wind-Solar Hybrid Power System

  • Lee, Yong-Sik;Gim, Jae-Hyeon
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1643-1653
    • /
    • 2014
  • This paper presents the design and implementation of a wind-solar hybrid power system for LED street lighting and an isolated power system. The proposed system consists of photovoltaic modules, a wind generator, a storage system (battery), LED lighting, and the controller, which can manage the power and system operation. This controller has the functions of maximum power point tracking (MPPT) for the wind and solar power, effective charging/discharging for the storage system, LED dimming control for saving energy, and remote data logging for monitoring the performance and maintenance. The proposed system was analyzed in regard to the operation status of the hybrid input power and the battery voltage using a PSIM simulation. In addition, the characteristics of the proposed system's output were analyzed through experimental verification. A prototype was also developed which uses 300[W] of wind power, 200[W] of solar power, 60[W] LED lighting, and a 24[V]/80[Ah] battery. The control system principles and design scheme of the hardware and software are presented.

Solar Tower용 흡수기의 설치 각도 및 작동 조건 변화에 따른 대류 열손실 분석 (Convective Heat Loss from Solar Tower Receiver with Tilt Angles and Operating Conditions)

  • 강경문;이주한;김용;서태범;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.121-128
    • /
    • 2007
  • Convective heat loss from solar tower receiver is experimentally investigated in wind tunnel with tilt angles and operating conditions. In order to simulate the receiver, an electric heater, which is made of aluminum (width : 100 mm, height : 100mm) is used and installed in the wind tunnel. The convective heat loss from the receiver is dependent on the direction and the velocity of the wind and the surface temperature of the receiver. The tilt angle and surface temperature of the receiver are varied from 0o (cavity facing straight down) and 90o(cavity aligned horizontally) and from $150^{\circ}C$ to $250^{\circ}C$, respectively. Also, the wind speed is changed from 0 to 4m/s. The convective heat loss is obtained by measuring consumed power to the heater to maintain the desired surface temperature. It is concluded that Nusselt number increases with increasing wind speed for all cases. Especially, it is showed that Nusselt number can be maximized when the tilt angle is 30o.

기상데이터와 웨이블 파라메타를 이용한 풍력에너지밀도분포 비교 (Comparison of Wind Energy Density Distribution Using Meteorological Data and the Weibull Parameters)

  • 황지욱;유기표;김한영
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.54-64
    • /
    • 2010
  • Interest in new and renewable energies like solar energy and wind energy is increasing throughout the world due to the rapidly expanding energy consumption and environmental reasons. An essential requirement for wind force power generation is estimating the size of wind energy accurately. Wind energy is estimated usually using meteorological data or field measurement. This study attempted to estimate wind energy density using meteorological data on daily mean wind speed and the Weibull parameters in Seoul, a representative inland city where over 60% of 15 story or higher apartments in Korea are situated, and Busan, Incheon, Ulsan and Jeju that are major coastal cities in Korea. According to the results of analysis, the monthly mean probability density distribution based on the daily mean wind speed agreed well with the monthly mean probability density distribution based on the Weibull parameters. This finding suggests that the Weibull parameters, which is highly applicable and convenient, can be utilized to estimate the wind energy density distribution of each area. Another finding was that wind energy density was higher in coastal cities Busan and Incheon than in inland city Seoul.

Three-dimensional MHD modeling of a CME propagating through a solar wind

  • An, Jun-Mo;Inoue, Satoshi;Magara, Tetsuya;Lee, Hwanhee;Kang, Jihye;Kim, Kap-Sung;Hayashi, Keiji;Tanaka, Takashi
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.70.2-70.2
    • /
    • 2014
  • We developed a three-dimensional (3D) magnetohydrodynamic (MHD) simulation code to reproduce the structure of a solar wind and the propagation of a coronal mass ejection (CME) through it. This code is constructed by a finite volume method based on a total variation diminishing (TVD) scheme using an unstructured grid system (Tanaka 1994). The grid system can avoid the singularity arising in the spherical coordinate system. In this study, we made an improvement of the code focused on the propagation of a CME through a solar wind, which extends a previous work done by Nakamizo et al. (2009). We first reconstructed a solar wind in a steady state from physical values obtained at 50 solar radii away from the Sun via an MHD tomography applied to interplanetary scintillation (IPS) data (Hayashi et al. 2003). We selected CR2057 and inserted a spheromak-type CME (Kataoka et al. 2009) into a reconstructed solar wind. As a result, we found that our simulation well captures the velocity, temperature and density profiles of an observed solar wind. Furthermore, we successfully reproduce the general characteristics of an interplanetary coronal mass ejection (ICME) obtained by the Helios 1/2 spacecraft (R. J. FORSYTH et al. 2006).

  • PDF

수치바람모의에 의한 저해상도 국가 바람지도의 구축 (Establishment of the Low-Resolution National Wind Map by Numerical Wind Simulation)

  • 김현구;장문석;경남호;이화운;최현정;김동혁
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.31-38
    • /
    • 2006
  • The national goal of wind energy dissemination has to be determined rationally based on technically available wind resource potential. For an accurate and scientific estimation of wind resource potential, a wind map is requisite. This paper introduces the national wind map of Korea established by numerical wind simulation. Therefore, quantification of national wind resource potential is now possible and is anticipating to be used as a core index for policy and strategy building of wind energy dissemination and technology development.

Earthward Flow Bursts in the Magnetotail Driven by Solar Wind Pressure Impulse

  • Kim, Khan-Hyuk;Kwak, Young-Sil;Lee, Jae-Jin;Hwang, Jung-A
    • Journal of Astronomy and Space Sciences
    • /
    • 제25권4호
    • /
    • pp.375-382
    • /
    • 2008
  • On August 31, 2001, ${\sim}$ 1705 - 1718 UT, Cluster was located near the midnight magnetotail, GSE (x, y, z) ${\sim}$ (-19, - 2,2) RE, and observed fast earthward flow bursts in the vicinity of the neutral sheet. They occurred while the tail magnetic field suddenly increased. Using simultaneous measurements in the solar wind, at geosynchronous orbit, and on the ground, it is confirmed that tail magnetic field enhancement is due to an increased solar wind pressure. In the neutral sheet region, strongly enhanced earthward flow bursts perpendicular to the local magnetic field $(V_{{\perp}x})$ were observed. Auroral brightenings localized in the pre-midnight sector (${\sim}$ 2200 - 2400 MLT) occurred during the interval of the $V_{{\perp}x}$ enhancements. The $V_{{\perp}x}$ bursts started ${\sim}$ 2 minutes before the onset of auroral brightenings. Our observations suggest that the earthward flow bursts are associated with tail reconnection directly driven by a solar wind pressure impulse and that $V_{{\perp}x}$ caused localized auroral brightenings.

온도와 풍속에 따른 태양광발전 효율 실증분석 연구 (A Study on Solar Power Generation Efficiency Empirical Analysis according to Temperature and Wind speed)

  • 차왕철;박정호;조욱래;김재철
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.1-6
    • /
    • 2015
  • Factors that have influence on solar power generation are specified into three aspects such as meteorological, geographical factors as well as equipment installation. Meteorological factors influence the most among the three. Insolation, sunshine hours, and cloud directly influence on solar power generation, whereas temperature and wind speed have impacts on equipment installation. This paper provides explanation over temperature-wind speed equation by calculating influence of temperature and wind speed on equipment installation. In order to conduct a research, pyranometer, anemometer, air thermometer, module thermometer are installed in 2MWp solar power plant located in South Cholla province, so that real-time meteorological data and generating amount can be analyzed through monitoring system. Besides, if existing and new methods are applied together, accuracy of prediction for generating amount is improved.

신재생에너지 적용에 따른 화력발전 경제성분석 (Analysis of Economical efficiency for renewable energy in Steam Power Plant)

  • 최경식
    • 환경영향평가
    • /
    • 제23권1호
    • /
    • pp.11-17
    • /
    • 2014
  • Since the Renewable Portfolio Standard (RPS) would be started in 2012, the use of renewable energy should be 11% of total energy use including bio-fuel in 2030. The economic efficiency for renewable energy in B power plant was considered with the bio-diesel, wind power and solar power. The Net Present Value (NPV) and Benefit/Cost Ratio(BC) were used for the economic efficiency with the cost and benefit analysis. In case of bio-diesel, the cost resulted from the fuel conversion and the benefit would be created with trade and environmental improvement. With regard to wind power and solar power, the construction cost would be required and benefit factors would be same as the bio-diesel. The wind power was the best of economic efficiency of renewable energy as the results of NPV and BC ratio. Whereas, the market of wind power was very popular and the techniques of wind power has been developing rapidly.