• 제목/요약/키워드: solar radiation quantity

검색결과 33건 처리시간 0.021초

TRNSYS를 이용한 지역별 고정형 태양광모듈 배치안 검토 (A Study on the Optimum Selection of Placing Photovoltaic Module In the Metropolitan City Using a TRNSYS)

  • 박성현;서장후
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.297-302
    • /
    • 2011
  • In this study, used Trnsys and will apply metropolitan city distinguishes, fixations and BIPV systems the photovoltaic module arrangement environment which receives solar radiation quantity plentifully from the case design process which and most the outcome value simulation did analyzed. The climate data uses each metropolitan city distinguishes 20 average weather data, With measured values of horizontal solar radiation. The error scope appeared with 0.1%~6.7%. Variable of module arrangement Azimuth and angle of inclination of module and comparison group Module on due south direction angle of inclination $45^{\circ}$ day time set with the yearly average solar radiation quantity which receives. The result When the case comparison group which arranges a solar storehouse module with optimum environment and comparing until the minimum 1.4% - maximum 10.9% the solar radiation quantity difference appears with the thing, metropolitan city distinguishes considers the case solar radiation quantity which will arrange a photovoltaic module and that must establish with optimum environment judges.

  • PDF

Measurement of local wind and solar radiation for a hybrid power generation system design, Busan, Korea

  • Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권7호
    • /
    • pp.799-806
    • /
    • 2013
  • As a first step to develop the hybrid power generation system, on this study, the time-variable resources of wind and solar radiation of Yeongdo, Busan, Korea had been measured during June and July 2013. And the quantity of generated wind power and solar photovoltaic had also been measured during the same period. It is found out that the wind mainly flew from southwest at the average speed of 2 m/s during 2 months. And it is clear that, because of the low wind velocity, the wind quality to generate the power seems not enough at this area. Meanwhile solar radiation was measured every daytime (6:00~19:00) and the peak solar radiation occurred around 12:00~14:00. And it is clear that the time-based variations of quantity of generated power were proportional to the variations of these resources, respectively. As a proposal, these 2 natural energies can be combined as resources of a hybrid system, because these 2 patterns are not overlapped so much on time base.

냉각시스템에 의한 태양광 발전의 효율 개선 (Solar Photovoltaic According to Installation of Cooling System)

  • 염성배;최홍규;최영준;홍성구;김태훈
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.66-71
    • /
    • 2009
  • 태양광 발전은 일사량이 높을수록 발전량이 증가된다. 그러나 일사량이 높아짐에 따라 셀의 온도도 같이 증가해 발전 효율은 감소하게 된다. 냉각시스템의 설치는 이러한 문제점을 해결하기 위한 적절한 방법이 될 수 있으나 냉각시스템 설치 후 태양광 발전량의 증가량, 냉각시스템의 설치비용, 냉각시스템의 유지 보수비용 등 실용화에 필요한 내용은 논의되고 있지 않다. 따라서 본 논문에서는 냉각시스템의 효과 및 상용화 가능성에 대해 기술하였다. 실험결과 냉각시스템 설치 후, 연평균 약 5.76[%]의 발전량 증가를 기대할 수 있다.

냉각시스템 설치에 따른 태양광 발전 (Solar photovoltaic according to installation of cooling system)

  • 홍성구;최홍규;유해출;이찬재;한상권;김태훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.189-192
    • /
    • 2008
  • 태양광 발전은 일사량이 높을수록 발전량이 증가된다. 그러나 일사량이 높아짐에 따라 셀의 온도도 같이 증가해 발전 효율은 감소하게 된다. 냉각시스템의 설치는 이러한 문제점을 해결하기 위한 적절한 방법이 될 수 있으나 냉각시스템 설치 후 태양광 발전량의 증가량, 냉각시스템의 설치비용, 냉각시스템의 유지 보수비용 등 실용화에 필요한 내용은 논의되고 있지 않다. 따라서 본 논문에서는 냉각시스템의 효과 및 상용화 가능성에 대해 기술하였다.

  • PDF

온실의 광환경 분석을 위한 기초실험 (The Basic Experiments for Analysis of Solar Radiation Environemnts in Greenhouse)

  • 이현우;이석건;김길동;이종원
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.434-438
    • /
    • 1999
  • It was neede to know the amount of PAR to predict the growth of crops, and the quantity of total radiation to control the temperature by shading screen in the greenhouse. Experiments have been conducted to determine the correlation between the hourly PAR and total solar radiation the transmisson of PAR and total solar radiaiton oat canopy location, and the relationship between the illuminaance and total solar radiation. Additional experiments are needed to confirm thses experimental results.

  • PDF

공동주택의 태양열 집열기 효율에 대한 실험적 연구 (An Experimental Study on the Solar Collector Efficiency for Apartment Building)

  • 최병도;김미연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

태양광어레이 방위각 및 경사각 변화에 따른 일사량 영향분석에 관한 연구 (A Study on the Influence to Solar Radiation by Changing the Azimuth and Tilt of a Photovoltaic Array)

  • 최영관;이남형;김건중;조용
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.712-716
    • /
    • 2013
  • In solar generation, the PV array's azimuth is headed due south and the tilt is generally $33^{\circ}$ in order to acquire maximum generation. However, when installed in a site where there are buildings or other facilities, the azimuth and tilt are adjusted. Yet, when the azimuth and tilt are deviated from due south and $33^{\circ}$, the generation quantity is decreased substantially and currently a method to estimate the decreasing proportion is unavailable. Therefore, in this thesis, an equation on the "change ratio of solar radiation due to the changes in tilt and azimuth" was deduced by utilizing empirical data on the amount of solar radiation received according to the changes of tilt and azimuth and Interpolation. By using this equation, the decreasing proportion of generating quantity due to the installation methods of PV system can be estimated, therefore, it can be usefully utilized when designing and going through feasibility studies for development of solar generation systems.

GIS기법을 이용한 일사량 모델링 (Insolation Modeling Using by GIS)

  • 김병우;강인준;김상석;곽재하
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.359-361
    • /
    • 2010
  • This research is thing about location choice of solar power generation equipment to increase efficiency of solar power generation equipment. In the case of current solar power generation equipment, location of large scale solar power generation equipment facilities choice or, have localized in small scale equipment by individual. This research uses various climatic elements of small scale area for efficient location choice of solar power generation facilities and quantity of solar radiation did back-tracking.

  • PDF

태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구 (A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test)

  • 김미연;최병도;김형근;박진철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

태양열 물펌프의 실험적 성능분석 (Experimental Analysis on the Performance of a Solar Powered Water Pump)

  • 김영복;손재길;이승규;김성태;나우정;이양근
    • Journal of Biosystems Engineering
    • /
    • 제29권6호
    • /
    • pp.521-530
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which electrical power is not available. The average solar radiation power is $3.488\;kWh/(m^2{\cdot}day)$ in Korea. In this study, the experimental system of the water pump driven by the radiation energy were designed, assembled, tested and analyzed fur realizing the solar powered water pump. Energy conversion ken radiation energy to mechanical energy by using n-pentane as operating material was done and the water pumping cycles were able to be continued. The quantity of the water pumped per cycle ranged from 2 L to 10 L depending on the level of the valve open area far the vapour supply. The average quantity was about 4,366 cc. The thermal efficiency was about $0.018\%$. The pressure level of the n-pentane vapour in flash tank was about $110\~150\;kPa$ and that in the water tank was $93\~130\;kPa$. The pressure in the condenser during cycles was maintained as about 70 kPa. The condensation of the n-pentane vapour in the water tank was increased with the cycles even though the internal and external insulation were done. Air tank performance was better with increasing of the water piston displacement and the water could be pumped with the water piston displacement becoming higher than 6,500 cc.