• Title/Summary/Keyword: solar photovoltaic energy

Search Result 1,274, Processing Time 0.026 seconds

Performance Change of Crystalline Photovoltaic Module in Modified Test Sequence (복합 환경시험 순서에 따른 태양전지모듈의 특성 변화)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Yoon, Soon-Gil
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.23-24
    • /
    • 2011
  • In this paper, I performed the IEC test in crystalline photovoltaic module described in test standard. And sometimes I changed the test sequence and impact factors for testing modules. Comparing the current test trees in IEC 61215, some ideas are suggested in proper test sequence to guarantee the long-term durability for 25 years.. The detail discussion will be shown in the following paper.

  • PDF

Near-IR Quantum Cutting Phosphors: A Step Towards Enhancing Solar Cell Efficiency

  • Jadhav, Abhijit P.;Khan, Sovann;Kim, Sun Jin;Cho, So-Hye
    • Applied Science and Convergence Technology
    • /
    • v.23 no.5
    • /
    • pp.221-239
    • /
    • 2014
  • The global demand for energy has been increasing since past decades. Various technologies have been working to find a suitable alternative for the generation of sustainable energy. Photovoltaic technologies for solar energy conversion represent one of the significant routes for the green and renewable energy production. Despite of remarkable improvement in solar cell technologies, the generation of power is still suffering with lower energy conversion efficiency, high production cost, etc. The major problem in improving the PV efficiency is spectral mismatch between the incident solar spectrum and bandgap of a semiconductor material used in solar cell. Luminescent materials such as rare-earth doped phosphor materials having the quantum efficiency higher than unity can be helpful for photovoltaic applications. Quantum cutting phosphors are the most suitable candidates for the generation of two or more low-energy photons for the absorption of every incident high-energy photons. The phosphors which are capable of converting UV photon to visible and near-IR (NIR) photon are studied primarily for photovoltaic applications. In this review, we will survey various near IR quantum cutting phosphors with respective to their synthesis method, energy transfer mechanism, nature of activator, sensitizer and dopant materials incorporation and energy conversion efficiency considering their applications in photovoltaics.

A Study on Solar Radiation Prediction using Artificial Neural Network (인공지능신경회로망을 이용한 태양광 예측)

  • Zhang, Fengming;Cho, Kyeong-Hee;Lim, Jin-Taek;Choi, Jae-Seok;Lee, Young-Mi;Lee, Kwang-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.354-356
    • /
    • 2011
  • Renewable energy resources such as wind, wave, solar, micro hydro, tidal and biomass etc. are becoming importance stage by stage because of considering effect of the environment. Solar energy is one of the most successful sources of renewable energy for the production of electrical energy following solar energy. And, the solar/photovoltaic cell generators depend on the solar radiation, which is a random variable so this poses difficulty in the system scheduling and energy dispatching, as the schedule of the photovoltaic cell generators availability is not known in advance. This paper proposes to use the two-layered artificial neural networks for predicting the actual solar radiation from the previous values of the same variable.

  • PDF

Development of Wireless IoT Sensors for Individual Photovoltaic Module Monitoring (태양광 모듈 개별 모니터링을 위한 무선 IoT센서)

  • Park, Jongsung;Kim, Changheon;Lee, Jiwon;Kim, Jihyun;Yoo, Sanghyuk;Yang, Bum Seung
    • Current Photovoltaic Research
    • /
    • v.9 no.3
    • /
    • pp.106-109
    • /
    • 2021
  • In order to perform photovoltaic (PV) operation and management (O&M) efficiently, individual PV module monitoring is becoming more important. In this research, we developed wireless IoT sensor which can monitor individual photovoltaic modules. This IoT sensor can detect the output voltage, current and module temperature of individual modules and provide monitored data by wireless communication. Measured voltage error was 1.23%, and it shows 16.6 dBM, 0.42sec and 7.1 mA for voltage, transmittance output, response time and mean power consumption, respectively. IoT sensors were demonstrated in the test field with real climate environment condition and each of 5 sensors showed precise results of voltage, current and temperature. Also, sensors were compared with commercial power-optimizers and showed result difference within 5%.

Characteristics Analysis of Proto-type Microconverter for Power Output Compensation of Photovoltaic Modules (태양광 모듈 출력 보상을 위한 마이크로컨버터 시제품 동작 특성 분석)

  • Jihyun, Kim;Ju-Hee, Kim;Jeongjun, Lee;Jongsung, Park;Changheon, Kim
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.133-137
    • /
    • 2022
  • The economic feasibility of a photovoltaic (PV) system is greatly influenced by the initial investment cost for system installation. Also, electricity generation by PV system is highly important. The profits competitiveness of PV system will be maximized through intelligent operation and maintenance (O&M). Here, we developed a microconverter which can maximize electricity generation from PV modules by tracking the maximum power point of PV modules, and help efficient O&M. Also, the microconverter mitigates current mismatch caused by shading, hence maximize power generation. The microconverters were installed PV modules and demonstrated through the field tests. Power outputs such as voltage, string current were measured with variuos weather environments and partial shadings. We found that PV modules with the microconvertors shows 12.05% higher power generation compared to the reference PV modules.

Policy implications for up-scaling of off-grid solar PV for increasing access to electricity in rural areas of Nepal: Best practices and lessons learned

  • Sapkota, Surya Kumar
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.6 no.1
    • /
    • pp.8-20
    • /
    • 2020
  • Nepal has huge potential of hydro and other renewable energy resources including solar energy. However, only 70% of the total population have access to electricity despite the long history of hydropower development in the country. Still more than 37% population in rural areas and around 73% population in Karnali Province, one of the least developed provinces, are living without access to electricity despite taking several initiatives and implementing various policies by government supporting electrification in off-grid rural areas. Government together with donors and private sector has extensively been promoting the off-grid solar photovoltaic (PV) echnology in un-electrified areas to increase electricity access. So far, more than 900,000 households in rural areas of Nepal are getting electricity from stand-alone solar PV systems. However, there are many challenges including financial, technical, institutional, and governance barriers in Nepal. This study based on extensive review of literatures and author's own long working experiences in renewable energy sector in Nepal, shares the best practices and lessons of off-grid solar PV for increasing access to electricity in rural areas of Nepal. This study suggests that flexible financial instruments, financial innovations, bundling of PV systems for concentrating energy loads, adopting standards process, local capacity building, and combination of technology, financing and institutional aspects are a key for enhancing effectiveness of solar PV technology in rural areas of Nepal.

Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module (PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

Generation of electricity Characteristics with Weather Conditions of Photocoltaics-Wind Power Hybrid System (태양광.풍력 복합발전시스템의 기상조건에 따른 발전특성)

  • Kang, Gi-Hwan;Jeong, Young-Seok;Yu, Gwon-Jong;Jeong, Myung-Woong;Song, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2581-2583
    • /
    • 1999
  • The PV-Wind hybrid system was installed in the island where the solar and wind energy was compensated each other. The installed hybrid system, 10kWp-PV and 10kW-wind capacity, was monitored with the varying solar intensity and wind speed, under the minimum capacity of the storage battery.

  • PDF

Estimation of energy self-sufficiency in municipal wastewater treatment plant using photovoltaic power simulated by azimuth and hydrophilic coating (방위각과 초친수코팅에 따른 태양광발전량 시뮬레이션과 하수처리장 에너지자립율 산정)

  • An, Young-Sub;Kim, Sung-Tae;Kang, Ji-Hoon;Chae, Kyu-Jung;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.133-138
    • /
    • 2011
  • This paper presents energy self-sufficiency simulated in municipal wastewater treatment plants (WWTPs) by adopting solar energy production systems that were simulated by varying azimuth and super-hydrophilic coating on the surface of photovoltaic (PV). Relative to the national average energy consumption in WWTPs, the employment of 100 kW PV system was simulated to achieve 2.75% of energy self-sufficiency. The simulated results suggested that the installation of PVs toward South or Southwest would produce the highest energy self-sufficiency in WWTPs. When super-hydrophilic coating was employed in the conventional PV, 5% of additional solar energy production was achievable as compared to uncoated conventional PV. When 100 kW of PV system was installed in a future test-bed site, Kihyeung Respia WWTP located in Yongin, South Korea, the energy self-sufficiency by solar power was simulated to be 1.77%. The simulated solar power production by azimuth and super-hydrophilic coating will be useful reference for practitioners in designing the solar PV systems in the WWTPs.

Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections (병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석)

  • Jung, Young-Seok;Yu, Byung-Gyu;Kang, Gi-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.