• Title/Summary/Keyword: solar

Search Result 11,204, Processing Time 0.045 seconds

A study on the soil $CO_2$ Efflux in Quercus acutissima stand at Mt. Bulam urban nature park (불암산 도시자연공원 상수리나무군락의 토양호흡 특성 연구)

  • Kim, Jeong-Seob;Kong, Seok-Jun;Yang, Keum-Chul
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.6
    • /
    • pp.762-768
    • /
    • 2014
  • The purpose of this study is to analyze the soil $CO_2$ efflux and micro-climate of a preserved forest area located in a Mt. bulam urban nature park Quercus acutissima stand from June 2013 to May 2014. The research showed that the soil and heterotrophic $CO_2$ efflux were $28.14{\pm}7.99$ to $582.47{\pm}318.51$ and $12.32{\pm}8.04$ to $415.71{\pm}159.92mg\;CO_2{\cdot}m^{-2}{\cdot}h^{-1}$, respectively. In addition the seasonal soil $CO_2$ efflux of summer, autumn, winter, spring were 1169.1, 454.81, 72.08 and $494.23g\;CO_2{\cdot}m^{-2}{\cdot}month^{-1}$, respectively. On the other hand, the seasonal heterotrophic $CO_2$ efflux were 526.20, 340.09, 45.13 and $374.9g\;CO_2{\cdot}m^{-2}{\cdot}month^{-1}$, respectively. Moreover, the annual soil and heterotrophic $CO_2$ efflux was found to be 2190.22 and $1286.33g\;CO_2{\cdot}m^{-2}{\cdot}yr^{-1}$, respectively. The exponential function was also utilized for the regression analysis in order to correlate the environmental factors with the soil and heterotrophic $CO_2$ efflux. It was found out that both air and soil temperatures were positively correlated with the soil and heterotrophic $CO_2$ efflux. However, the amount of solar radiation and soil moisture has showed low correlation for both types of $CO_2$ efflux. Contribution of root $CO_2$ efflux to total soil $CO_2$ efflux in this Quercus acutissima stand was 33.60%.

Growth Performances of Seedlings of Daphniphyllum macropodum in Naejang National Park for Container Seeding Production (시설양묘에 적용을 위한 내장산 굴거리 나무 군락내 치수의 생장 특성)

  • Chung, Jin-Chul;Jeong, Ji-Young;Choi, Jeong-Ho;Jeon, Kyung-Soo;Bae, Jong-Hyang
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.365-372
    • /
    • 2011
  • This study aimed to examine foundational data for container seedling production with the subject of Daphniphyllum macropodum community in Mt. Naejang National Park. To achieve the goal, it investigated the growth characteristics of young tree seedlings growing in places with different light intensity environment. Regarding the growth environment of Daphniphyllum macropodum community, it was typical heavy rain summer climate, and the soil was silt loam with the organic content as 11.42~15.61%, total nitrogen as 0.50~0.76%, cation exchangeable capacity (C.E.C) as 18.92~23.32 cmol/kg, and pH as 4.85~5.58. About light intensity environment changed by research plots, relative transmittance of solar radiation was 71~76% in plot A, 37~42% in plot B, 65~70% in plot C, and 28~33% in plot D. The seedlings tended to be intensively distributed either under the crown of their mother tree or in the slope site, and plot A and C where light intensity environment is relatively more favorable showed 1,550 tree/ha and 1,250 tree/ha. Total biomass production of Daphniphyllum macropodum seedlings was 5.37 g in plot A and 5.29 g in plot C, so they were higher than 4.42~4.51 g in plot B and D with relatively less favorable light intensity environment. The T/R ratio was 1~2, leaf area rate was $139.71{\sim}183.50cm^2{\cdot}g^{-1}$, leaf area ratio was $39.68{\sim}60.66cm^2{\cdot}g^{-1}$, and leaf dry weight ratio grew higher in the range of $0.28{\sim}0.33cm^2{\cdot}g^{-1}$ as the intensity of radiation became less. It is thought that in the generation and growth of Daphniphyllum macropodum seedlings, the intensity of light has more effects than the organic content in soil. And it is also thought that in the application of container seedlings production, light environment management over 65~70% to full sun light intensity will affect significantly the initial growth of Daphniphyllum macropodum.

Effect of Design Value Selection on Heating and Cooling Load Calculation in Greenhouses (설계 변수 선택이 온실의 냉난방부하 산정에 미치는 영향)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.277-284
    • /
    • 2018
  • For the main variables to be selected by the designer for the heating and cooling load calculation in greenhouses, in order to evaluate the effect of these design values on the heating and cooling load, the simulations were carried out by varying the respective design values. Based on these results, we proposed the design values which should pay special attention to selection. The design values which have the greatest effect on the heating load were the overall heat transfer coefficient of the covering material and the design outdoor temperature was next. The effect of the design values according to the number of spans showed little difference. In the case of the single-span greenhouse, the effect of the design values related to the underground heat transfer can not be ignored. However, in the case of the multi-span greenhouse, the effect of the design values related to the underground heat transfer and the infiltration rate were insignificant. The design values which have the greatest effect on the cooling load were the solar radiation into the greenhouse and the evapotranspiration coefficient, followed by the indoor and outdoor temperature difference and the ventilation rate. The effect of the design values showed a great difference between the single-span greenhouse and the multi-span greenhouse, but there was almost no difference according to the number of spans. The effect of the overall heat transfer coefficient of the covering material was negligible in both the single-span greenhouse and the multi-span greenhouse. However, the effect of the indoor and outdoor temperature difference and the ventilation rate on the cooling load was not negligible. Especially, it is considered that the effect is larger in multi-span greenhouse.

Performance Improvement of a Temperature and Humidity Measuring System for Strawberry Cultivation Greenhouse (딸기재배 온실용 온습도 계측시스템의 성능개선)

  • Jeong, Young Kyun;Lee, Jong Goo;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.110-119
    • /
    • 2020
  • This study investigates the improvement in the performance of a temperature and humidity measuring system developed by Company A using the Aspirated Radiation Shield (ARS). The shield has been used in the industry and its accuracy was verified recently. The study also experimentally examines the impact of the wind speed of the ARS device on temperature and humidity. The results are summarized as follows. Before the improvement of the system, the temperature of Company A's system was up to 10.2℃ higher than that measured by the ARS device, and the measured relative humidity was approximately 20.0% lower. After improving the system, the temperature and relative humidity of nodes 1 and 2 were found to be almost identical. The temperature deviations including the maximum, mean, and minimum temperatures between those measured in node 2 and by ARS were approximately 0.2 to 0.7℃, respectively; further, the values measured by ARS tended to be slightly lower or higher. In terms of relative humidity, the ARS measurements yielded values approximately 10.0% higher immediately after sunset; otherwise, the values were approximately 1.9% lower. Moreover, when node 1 was set to minimum-middle, middle-maximum, and maximum, the deviations including the maximum, mean, and minimum temperatures of nodes 1 and 2 were 0.1 to 0.4℃, 0.0 to 0.2℃, and 0.0 to 0.5℃, respectively. The deviations including the maximum, average, and minimum temperatures of the three points of node 1 and the ARS ranged from 0.2 to 0.5℃, 0.1 to 2.2℃, and 0.1 to 1.1℃, respectively, indicating that the temperature deviation according to the wind speed was negligible. In addition, considering the results of the previous study with those from this study, the optimal wind speed to improve the temperature deviation is considered to be in the range of 1.0~2.0 m·s-1.

Photoprotection and Anti-inflammatory Effects of Chinese Medical Plants (약용식물추출물의 광보호 효과와 항염증 효과 연구)

  • Jin-Hwa, Kim;Sung-Min, Park;Gwan-Sub, Sim;Bum-Chun , Lee;Hyeong-Bae, Pyo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.227-233
    • /
    • 2004
  • Chronic exposure to solar radiation, particularly ultraviolet (UV) light, causes a variety of adverse reactions on human skin, such as sunburn, photoaging and photocarcinogenesis. Free radicals and reactive oxygen species (ROS) caused by UV exposure or other environmental facts play critical roles in cellular damage. And, repeated-UV irradiation activated the expression of the matrix metalloproteinase (MMP) and induced skin irritation. Therefore, the development of effective and safe photoprotectants that can reduce and improve the skin damage has been required. The purpose of this study was to investigate the photo-protective effect of several chinese medical plants (Juniperus chinensis) on the UV -induced skin cell damages. We tested free radical and superoxide scavenging effect in vitro. Fluorometric assays of the proteolytic activities of MMP-1 (collagenase) were performed using fluorescent collagen substrates. UVA induced MMP-1 synthesis and activity were analyzed by enzyme-linked immunosorbent assay (ELISA) and gelatin-based zymography in skin fibroblasts. We also examined anti-inflammatory effects by the determination test of proinflammatory cytokine, interleukin 6 in HaCaT keratinocytes. Expression of prostaglandin E$_2$ (PGE$_2$) after UVB irradiation was measured by competitive enzyme immunoassay(EIA) using PGE$_2$ monoclonal antibody. In the human skin we tested anti-irritation effect on the SLS-induced damage skin after appling the extract containing emulsion. We found that Juniperus chinensis extract had potent radical scavenging effect by 98% at 100$\mu\textrm{g}$/mL. The extract of Juniperus chinensis showed strong inhibitory effect on MMP-1 activities by 97% at 100 $\mu\textrm{g}$/mL and suppressed the UVA induced expression of MMP-1 by 79% at 25$\mu\textrm{g}$/mL. This extract also showed strong inhibition on MMP-2 activity in UVA irradiated fibroblast by zymography. In the test of proinflammatory cytokines of human keratinocytes Juniperus chinensis extract decreased expression of interleukin 6 about 30%. The amount of PGE$_2$ by HaCaT keratinocytes was significantly increased at the doses of above 10 mJ/$\textrm{cm}^2$ of UVB (p < 0.05). At the concentrations of 3.2-25$\mu\textrm{g}$/mL of this extract, the production of PGE$_2$ by HaCaT keratinocytes (24 h after 10mJ/$\textrm{cm}^2$ UVB irradiation) was significantly inhibited in culture supernatants (p < 0.05). In SLS-induced skin irritation model in vivo, we found to reduce skin erythema and improve barrier recovery after appling Juniperus chinensis extract containing emulsion when compared to irritated non-treated and placebo-treated skin. Our results suggest that Juniperus chinensis extract can be effectively used for the prevention of UV and SLS-induced adverse skin reactions and applied as anti-aging and anti-irritation cosmetics.

The Related Research with the Land Cover State and Temperature in the Outer Space of the Super-High-Rise Building (초고층 건축물 외부공간의 토지 피복 상태와 온도와의 관계 연구)

  • Han, Bong-Ho;Kim, Hong-Soon;Jung, Tae-Jun;Hong, Suk-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.6
    • /
    • pp.751-762
    • /
    • 2010
  • In order to understand the influence that the plant cover condition of the high-rise building outer space causes to the temperature change, we selected 12 high-rise building constructed in Seoul City. The land cover type of the outside was classified into six type(outer road, paved surface, shrub/grassland, single-layer tree planting-site, multi-layer planting-site, and waterscape facilities) and the temperature was measured at the representative point for each type in order to analyze the land cover temperature differential for each type of the high-rise building outer space. The study area showing the temperature tendency to be similar based upon one way analysis of variance after selecting the central part of the outer road for a control and measuring a temperature in order to consider the neighboring environmental difference of the dozen building was classified into 4 groups. As to the one-way layout result of variance analysis with the land cover type of the classified group and outer space temperature, the single-layer tree planting-site, waterscape facilities, and multi-layer planting-site belonged mainly to the low temperature section. The shrub/grassland, paved surface, and outer road belonged to the high temperature region. The temperature difference between low temperature region and high temperature region is about $1.06{\sim}6.17^{\circ}C$. However, the temperature in the Outer Space of the Super-High-Rise Building was variously appeared by the influence such as the cramped of the created planting-site and waterscape facilities area, the increase of amount of solar radiation and the reduction of reflection amount of light due to building etc.. Thus, the composition all produced the area of the green quantity required for each space and water space in advance. It was determined that there were the minimum area displaying an effect and the necessity to it secures the green quantity.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Effect of Curing Conditions on Inhibition of Tuber Rot in Subtropical Yam (Dioscorea alata) during Storage (아열대 마(Dioscorea alata)의 저장중 부패 억제를 위한 큐어링 효과)

  • Kim, Ki-Sun;Kwon, Soon-Bae;Chang, Kwang-Jin;Hong, Sae-Jin;Kim, Byung-Sup
    • Korean Journal of Plant Resources
    • /
    • v.25 no.4
    • /
    • pp.387-393
    • /
    • 2012
  • In order to improve storability of subtropical yam produced in South Korea, the major pathogens found during the storage were isolated and identified of the pathogenicity, and rot inhibition effect was studied based on the curing treatment condition. Penicillium sclerotigenum and Penicillium polonicum were identified as major pathogens causing rot in subtropical yam during storage, and P. sclerotigenum had stronger pathogenicity. Only the cut surface which has been made during a harvest and has been made smooth before curing generated a normal callus layer. The cut surface of tuberous root was cured in 95% of relativity humidity for three days at $23^{\circ}C$, and cured at $28^{\circ}C$ and $33^{\circ}C$. The observation of callus layer showed that the $23^{\circ}C$ treatment group had similar color saturation between tuberous root and pellicle, while the groups treated above $28^{\circ}C$ showed clear distinction. The generation rate of callus 0.5mm or bigger was 93 percent at $28^{\circ}C$ treatment, 96% at $33^{\circ}C$ treatment, but was 52% at $23^{\circ}C$ treatment. The conventional curing treatment group that used wind or sunlight at room temperature created little callus layer. The infection rate of pathogens according to the relative humidity inside the storage room was low at 40% and 60% of humidity, and the curing treatment period did not make a difference. When the humidity inside the storage room was 80%, all treatment groups rapidly increased the fungal pathogens. The rotten rate of each treatment was studied after 180 days during which the storage temperature was maintained at $16^{\circ}C$ and relative humidity 60%. While the rotten rate of tuberous root that has been cut in conventional curing treatment based on solar and wind was 43%, the one cured at over $28^{\circ}C$ and created the callus layer was less than 18%. While even a healthy tuberous root showed 25% of rotten rate in the traditional treatment group, the one cured at over $28^{\circ}C$ was less than 10%. The weight loss was 1-6% lower in the forced treatment group than in the conventional treatment group.

Drying of Rough Rice by Solar Collectors (태양(太陽) 열(熱 )집열기(集熱機)를 이용(利用)한 벼의 건조(乾燥)에 관(關)한 연구(硏究))

  • Chang, Kyu-Seob;Kim, Man-Soo;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.264-272
    • /
    • 1979
  • The flat-plate and tubular soar collectors were designed and constructed for drying the rough rice, and the performance of the collectors and drying effect were investigated when rough rice was packed in grain bin connected to collectors. Average-monthly radiation on a horizontal surface based on bright sunshine in Daejeon area during 1978 was the highest as $16,814\;KJ/m^2{\cdot}day$ in May and the lowest as $4,254\;KJ/m^2{\cdot}day$ in December, and significane was not recognized between the calculated and recorded values. The thermal effciency of collectors were increased as radiation increased during drying period and the average thermal effciency of flat-plate and tubular collectors in 11 to 12 o'clock a.m were 28.12 and 16.75%, respectively. The average inlet temperature of grain bin at 12 o'clock was shown as 20.02 at control 40.5 at grain bin connected to tubular collector and $55.1^{\circ}C$ at grain bin connected to flat-plate collector. In 25 cm rough rice depth in grain bin, tim taken for drying from initial moisture content at 27.4 to decrease upto 17.0% (14.5 % on wet basis) were 32 in control, 18 in grain bin connected to tubular collector and 11 hrs to flat-plate collector, and grain depth influenced drying rate remarkably. In the view point of drying characteristics, drying pattern showed initially falling-rate to constant-rate period finally.

  • PDF

A Study on Optimal Site Selection for Automatic Mountain Meteorology Observation System (AMOS): the Case of Honam and Jeju Areas (최적의 산악기상관측망 적정위치 선정 연구 - 호남·제주 권역을 대상으로)

  • Yoon, Sukhee;Won, Myoungsoo;Jang, Keunchang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.208-220
    • /
    • 2016
  • Automatic Mountain Meteorology Observation System (AMOS) is an important ingredient for several climatological and forest disaster prediction studies. In this study, we select the optimal sites for AMOS in the mountain areas of Honam and Jeju in order to prevent forest disasters such as forest fires and landslides. So, this study used spatial dataset such as national forest map, forest roads, hiking trails and 30m DEM(Digital Elevation Model) as well as forest risk map(forest fire and landslide), national AWS information to extract optimal site selection of AMOS. Technical methods for optimal site selection of the AMOS was the firstly used multifractal model, IDW interpolation, spatial redundancy for 2.5km AWS buffering analysis, and 200m buffering analysis by using ArcGIS. Secondly, optimal sites selected by spatial analysis were estimated site accessibility, observatory environment of solar power and wireless communication through field survey. The threshold score for the final selection of the sites have to be higher than 70 points in the field assessment. In the result, a total of 159 polygons in national forest map were extracted by the spatial analysis and a total of 64 secondary candidate sites were selected for the ridge and the top of the area using Google Earth. Finally, a total of 26 optimal sites were selected by quantitative assessment based on field survey. Our selection criteria will serve for the establishment of the AMOS network for the best observations of weather conditions in the national forests. The effective observation network may enhance the mountain weather observations, which leads to accurate prediction of forest disasters.