• Title/Summary/Keyword: software test

Search Result 3,608, Processing Time 0.036 seconds

A Study of the shade of between maxillary and mandibular anterior teeth in the Korean (한국인의 상하악 전치부 색조에 관한 연구)

  • Kim, Tae-Jin; Kwon, Kung-Rock;Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.343-350
    • /
    • 2008
  • Purpose: The purpose of this study was to spectrophotometrically evaluate the shade difference between of maxillary and mandibular anterior teeth in the Korean by the standard of vita classical shade guide using $SpectroShade^{TM}$. Material and methods: In this study, the shades of healthy anterior teeth were examined and analyzed using the digital shade analysis of $SpectroShade^{TM}$. This study examined 80 individuals in their twenties, thirties, fourties, fifities ages and 40 males and 40 females, presenting 12 healthy, unrestored maxillary and mandibular anterior teeth. Tooth brushing and oral prophylaxis were performed prior to evaluation. The $SpectroShade^{TM}$ was used to acquire images of the 12 maxillary and mandibular anterior teeth. These images were analyzed using $SpectroShade^{TM}$ Software, and shade maps of each tooth were acquired. The shade difference of upper and lower, and gender differences and ages difference were investigated and analyzed with CIE $L^{*}a^{*}b^{*}$ color order system. One-Way ANOVA test was used to find out if there were significant differences between groups tested and Sheffe multiple comparison was used to identify where the differences were. Results: 1. Shade differences were significant (P < .05) between maxillary and mandibular central incisor, lateral incisor, canine. 2. No significant differences in shade distribution were seen between lateral incisors and central incisors. 3. Canine's shade difference were more significant than central incisor's and lateral incisors's. 4. No significant differences in shade distribution were seen between genders in maxillary and mandibulr central incisor, lateral incisor, canine. 5. No significant differences in shade distribution were seen in order of years in maxillary and mandibulr central incisor, lateral incisor, canine. Conclusions: The results of this study show that 1. Shade difference was founded in maxillary and mandibular anterior teeth and ${\Delta}E^{*}$ value was more than 2.0. 2. Canine's shade difference were more significant than central incisor's and lateral incisors's and between central incisors and lateral incisors shade differences were no significant. 3. No significant differences in shade distribution were seen between genders in maxillary and mandibular anterior teeth. 4. No significant differences in shade distribution were seen in order of years grade in maxillary and mandibular anterior teeth.

Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files (Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가)

  • Kim, Joo Seob;Ahn, Woo Sang;Lee, Woo Suk;Park, Sung Ho;Choi, Wonsik;Shin, Seong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • Purpose : The purpose of this study is to analyze the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC) and determine the appropriate period of quality assurance (QA). Materials and Methods : The quality assurance of the DMLC equipped with Millennium 120 leaves has been performed total 92 times from January 2012 to June 2014. The the accuracy of leaf position and isocenter coincidence for MLC were checked using the graph paper and Gafchromic EBT film, respectively. The stability of leaf speed was verified using a test file requiring the leaves to reach maximum leaf speed during the gantry rotation. At the end of every leaf speed QA, dynamic dynalog files created by MLC controller were analyzed using dynalog file viewer software. This file concludes the information about the planned versus actual position for all leaves and provides error RMS (root-mean square) for individual leaf deviations and error histogram for all leaf deviations. In this study, the data obtained from the leaf speed QA were used to screen the performance degradation of leaf speed and determine the need for motor replacement. Results : The leaf position accuracy and isocenteric coincidence of MLC was observed within a tolerance range recommanded from TG-142 reports. Total number of motor replacement were 56 motors over whole QA period. For all motors replaced from QA, gradually increased patterns of error RMS values were much more than suddenly increased patterns of error RMS values. Average error RMS values of gradually and suddenly increased patterns were 0.298 cm and 0.273 cm, respectively. However, The average error RMS values were within 0.35 cm recommended by the vendor, motors were replaced according to the criteria of no counts with misplacement > 1 cm. On average, motor replacement for gradually increased patterns of error RMS values 22 days. 28 motors were replaced regardless of the leaf speed QA. Conclusion : This study performed the periodic MLC QA for analyzing the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC). The leaf position accuracy and isocenteric coincidence showed whthin of MLC evaluation is observed within the tolerance value recommanded by TG-142 report. Based on the result obtained from leaf speed QA, we have concluded that QA protocol of leaf speed for DMLC was performed at least bimonthly in order to screen the performance of leaf speed. The periodic QA protocol can help to ensure for delivering accurate IMRT treatment to patients maintaining the performance of leaf speed.

How Can Non.Chaebol Companies Thrive in the Chaebol Economy? (비재벌공사여하재재벌경제중생존((非财阀公司如何在财阀经济中生存)? ‐공사층면영소전략적분석(公司层面营销战略的分析)‐)

  • Kim, Nam-Kuk;Sengupta, Sanjit;Kim, Dong-Jae
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.3
    • /
    • pp.28-36
    • /
    • 2009
  • While existing literature has focused extensively on the strengths and weaknesses of the Chaebol and their ownership and governance, there have been few studies of Korean non-Chaebol firms. However, Lee, Lee and Pennings (2001) did not specifically investigate the competitive strategies that non-Chaebol firms use to survive against the Chaebol in the domestic Korean market. The motivation of this paper is to document, through four exploratory case studies, the successful competitive strategies of non-Chaebol Korean companies against the Chaebol and then offer some propositions that may be useful to other entrepreneurial firms as well as public policy makers. Competition and cooperation as conceptualized by product similarity and cooperative inter.firm relationship respectively, are major dimensions of firm.level marketing strategy. From these two dimensions, we develop the following $2{\times}2$ matrix, with 4 types of competitive strategies for non-Chaebol companies against the Chaebol (Fig. 1.). The non-Chaebol firm in Cell 1 has a "me-too" product for the low-end market while conceding the high-end market to a Chaebol. In Cell 2, the non-Chaebol firm partners with a Chaebol company, either as a supplier or complementor. In Cell 3, the non-Chaebol firm engages in direct competition with a Chaebol. In Cell 4, the non-Chaebol firm targets an unserved part of the market with an innovative product or service. The four selected cases such as E.Rae Electronics Industry Company (Co-exister), Intops (Supplier), Pantech (Competitor) and Humax (Niche Player) are analyzed to provide each strategy with richer insights. Following propositions are generated based upon our conceptual framework: Proposition 1: Non-Chaebol firms that have a cooperative relationship with a Chaebol will perform better than firms that do not. Proposition 1a; Co-existers will perform better than Competitors. Proposition 1b: Partners (suppliers or complementors) will perform better than Niche players. Proposition 2: Firms that have no product similarity with a Chaebol will perform better than firms that have product similarity. Proposition 2a: Partners (suppliers or complementors) will perform better than Co.existers. Proposition 2b: Niche players will perform better than Competitors. Proposition 3: Niche players should perform better than Co-existers. Proposition 4: Performance can be rank.ordered in descending order as Partners, Niche Players, Co.existers, Competitors. A team of experts was constituted to categorize each of these 216 non-Chaebol companies into one of the 4 cells in our typology. Simple Analysis of Variance (ANOVA) in SPSS statistical software was used to test our propositions. Overall findings are that it is better to have a cooperative relationship with a Chaebol and to offer products or services differentiated from a Chaebol. It is clear that the only profitable strategy, on average, to compete against the Chaebol is to be a partner (supplier or complementor). Competing head on with a Chaebol company is a costly strategy not likely to pay off for a non-Chaebol firm. Strategies to avoid head on competition with the Chaebol by serving niche markets with differentiated products or by serving the low-end of the market ignored by the Chaebol are better survival strategies. This paper illustrates that there are ways in which small and medium Korean non-Chaebol firms can thrive in a Chaebol environment, though not without risks. Using different combinations of competition and cooperation firms may choose particular positions along the product similarity and cooperative relationship dimensions to develop their competitive strategies-co-exister, competitor, partner, niche player. Based on our exploratory case-study analysis, partner seems to be the best strategy for non-Chaebol firms while competitor appears to be the most risky one. Niche players and co-existers have intermediate performance, though the former do better than the latter. It is often the case with managers of small and medium size companies that they tend to view market leaders, typically the Chaebol, with rather simplistic assumptions of either competition or collaboration. Consequently, many non-Chaebol firms turn out to be either passive collaborators or overwhelmed competitors of the Chaebol. In fact, competition and collaboration are not mutually exclusive, and can be pursued at the same time. As suggested in this paper, non-Chaebol firms can actively choose to compete and collaborate, depending on their environment, internal resources and capabilities.

  • PDF

Effects of the Variability of Individual Data on the Group Results; an Acupuncture Study Using fMRI (기능적 자기공명영상을 이용한 침 연구에 있어서 개체 별 다양성이 그룹분석에 미치는 영향 연구)

  • Bae, Seong-In;Jahng, Geon-Ho;Ryu, Chang-Woo;Lim, Sabina
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.277-289
    • /
    • 2009
  • Recently, functional MRI has been used to investigate the neurobiological mechanisms of acupuncture and the specificity of acupoint. The group data tend to be regarded as more important than the individual data in the most of previous studies. This study was designed to investigate the effect of the variability of individual data on the group results. A functional MRI (fMRI) of the whole brain was performed in fifteen healthy subjects during placebo and acupuncture stimulations at the ST36 acupoint. After remaining at rest for 30 seconds, the acupuncture was inserted and twisted at the rate of 2 Hz for 45 seconds and then the acupuncture was removed immediately. This process was repeated three times. Individual and group analyses were performed by voxel-based analyses using SPM2 software. Visual inspections of the activation and deactivation maps from individual sessions have shown the large variability across fifteen subjects. This means that the group data reflected the brain activation responses of only a few subjects. We suggest that the individual data should be presented to demonstrate the effect of acupuncture.

  • PDF

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

Recommender Systems using Structural Hole and Collaborative Filtering (구조적 공백과 협업필터링을 이용한 추천시스템)

  • Kim, Mingun;Kim, Kyoung-Jae
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.4
    • /
    • pp.107-120
    • /
    • 2014
  • This study proposes a novel recommender system using the structural hole analysis to reflect qualitative and emotional information in recommendation process. Although collaborative filtering (CF) is known as the most popular recommendation algorithm, it has some limitations including scalability and sparsity problems. The scalability problem arises when the volume of users and items become quite large. It means that CF cannot scale up due to large computation time for finding neighbors from the user-item matrix as the number of users and items increases in real-world e-commerce sites. Sparsity is a common problem of most recommender systems due to the fact that users generally evaluate only a small portion of the whole items. In addition, the cold-start problem is the special case of the sparsity problem when users or items newly added to the system with no ratings at all. When the user's preference evaluation data is sparse, two users or items are unlikely to have common ratings, and finally, CF will predict ratings using a very limited number of similar users. Moreover, it may produces biased recommendations because similarity weights may be estimated using only a small portion of rating data. In this study, we suggest a novel limitation of the conventional CF. The limitation is that CF does not consider qualitative and emotional information about users in the recommendation process because it only utilizes user's preference scores of the user-item matrix. To address this novel limitation, this study proposes cluster-indexing CF model with the structural hole analysis for recommendations. In general, the structural hole means a location which connects two separate actors without any redundant connections in the network. The actor who occupies the structural hole can easily access to non-redundant, various and fresh information. Therefore, the actor who occupies the structural hole may be a important person in the focal network and he or she may be the representative person in the focal subgroup in the network. Thus, his or her characteristics may represent the general characteristics of the users in the focal subgroup. In this sense, we can distinguish friends and strangers of the focal user utilizing the structural hole analysis. This study uses the structural hole analysis to select structural holes in subgroups as an initial seeds for a cluster analysis. First, we gather data about users' preference ratings for items and their social network information. For gathering research data, we develop a data collection system. Then, we perform structural hole analysis and find structural holes of social network. Next, we use these structural holes as cluster centroids for the clustering algorithm. Finally, this study makes recommendations using CF within user's cluster, and compare the recommendation performances of comparative models. For implementing experiments of the proposed model, we composite the experimental results from two experiments. The first experiment is the structural hole analysis. For the first one, this study employs a software package for the analysis of social network data - UCINET version 6. The second one is for performing modified clustering, and CF using the result of the cluster analysis. We develop an experimental system using VBA (Visual Basic for Application) of Microsoft Excel 2007 for the second one. This study designs to analyzing clustering based on a novel similarity measure - Pearson correlation between user preference rating vectors for the modified clustering experiment. In addition, this study uses 'all-but-one' approach for the CF experiment. In order to validate the effectiveness of our proposed model, we apply three comparative types of CF models to the same dataset. The experimental results show that the proposed model outperforms the other comparative models. In especial, the proposed model significantly performs better than two comparative modes with the cluster analysis from the statistical significance test. However, the difference between the proposed model and the naive model does not have statistical significance.

On-line Quality Assurance of Linear Accelerator with Electronic Portal Imaging System (전자포탈영상장치(EPID)를 이용한 선형가속기의 기하학적 QC/QA System)

  • Lee, Seok;Jang, Hye-Sook;Choi, Eun-Kyung;Kwon, Soo-Il;Lee, Byung-Yong
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.127-136
    • /
    • 1998
  • On-line geometrical quality assurance system has been developed using electronic portal imaging system(OQuE). EPID system is networked into Pentium PC in order to transmit the acquisited images to analysis PC. Geometrical QA parameters, including light-radiation field congruence, collimator rotation axis, and gantry rotation axis can be easily analyzed with the help of graphic user interface(GUI) software. Equipped with the EPID (Portal Vision, Varian, USA), geometrical quality assurance of a linear accelerator (CL/2100/CD, Varian, USA), which is networked into OQuE, was performed to evaluate this system. Light-radiation field congruence tests by center of gravity analysis shows 0.2~0.3mm differences for various field sizes. Collimator (or Gantry) rotation axis for various angles could be obtained by superposing 4 shots of angles. The radius of collimator rotation axis is measured to 0.2mm for upper jaw collimator, and 0.1mm for lower jaw. Acquisited images for various gantry angles were rotated according to the gantry angle and actual center of image point obtained from collimator axis test. The rotated images are superpositioned and analyzed as the same method as collimator rotation axis. The radius of gantry rotation axis is calculated 0.3mm for anterior/posterior direction (gantry 0$^{\circ}$ and 170$^{\circ}$) and 0.7mm for right/left direction(gantry 90$^{\circ}$ and 260$^{\circ}$). Image acquisition for data analysis is faster than conventional method and the results turn out to be excellent for the development goal and accurate within a milimeter range. The OQuE system is proven to be a good tool for the geometrical quality assurance of linear accelerator using EPID.

  • PDF

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF

IMAGING SIMULATIONS FOR THE KOREAN VLBI NETWORK(KVN) (한국우주전파관측망(KVN)의 영상모의실험)

  • Jung, Tae-Hyun;Rhee, Myung-Hyun;Roh, Duk-Gyoo;Kim, Hyun-Goo;Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2005
  • The Korean VLBI Network (KVN) will open a new field of research in astronomy, geodesy and earth science using the newest three Elm radio telescopes. This will expand our ability to look at the Universe in the millimeter regime. Imaging capability of radio interferometry is highly dependent upon the antenna configuration, source size, declination and the shape of target. In this paper, imaging simulations are carried out with the KVN system configuration. Five test images were used which were a point source, multi-point sources, a uniform sphere with two different sizes compared to the synthesis beam of the KVN and a Very Large Array (VLA) image of Cygnus A. The declination for the full time simulation was set as +60 degrees and the observation time range was -6 to +6 hours around transit. Simulations have been done at 22GHz, one of the KVN observation frequency. All these simulations and data reductions have been run with the Astronomical Image Processing System (AIPS) software package. As the KVN array has a resolution of about 6 mas (milli arcsecond) at 220Hz, in case of model source being approximately the beam size or smaller, the ratio of peak intensity over RMS shows about 10000:1 and 5000:1. The other case in which model source is larger than the beam size, this ratio shows very low range of about 115:1 and 34:1. This is due to the lack of short baselines and the small number of antenna. We compare the coordinates of the model images with those of the cleaned images. The result shows mostly perfect correspondence except in the case of the 12mas uniform sphere. Therefore, the main astronomical targets for the KVN will be the compact sources and the KVN will have an excellent performance in the astrometry for these sources.

Reanalysis of 2007 Korean National Health and Nutrition Examination Survey (2007 KNHANES) Results by CAN-Pro 3.0 Nutrient Database (2007년도 국민건강영양조사 결과 재분석 : CAN-Pro 3.0 식품영양가표의 활용)

  • Shim, Youn-Jeong;Paik, Hee-Young
    • Journal of Nutrition and Health
    • /
    • v.42 no.6
    • /
    • pp.577-595
    • /
    • 2009
  • This study aimed to reanalyze energy and nutrient intakes of 2007 Korean Nutrition and Health Examination Survey (KNHANES) using CAN-Pro 3.0, a commonly used nutrient analysis software in Korea. Food items and their codes were selected from 2007 KNHANES dietary intake file and converted to food codes of CAN-Pro 3.0 nutrient database (NDB). Of the 1,324 total food items, 1,155 items were converted by direct matching, 123 items were matched using other items in CAN-Pro 3.0 NDB and 42 items were matched using external sources. Consumption frequencies of items converted by direct matching contributed 94.5% of total consumption. Nutrient intakes of 4,091 participants of 2007 KNHANES, over 1 year old, were recalculated using CAN-Pro 3.0 NDB and compared with intakes in 2007 KNHANES dietary intake file. Intakes for energy and all nutrients except protein and Vitamin C calculated by two NDBs were significantly different by paired t-test (p < 0.001), but significantly correlated by Pearson' correlation coefficients (p < 0.001). Percent differences between the NDBs ranged from 0.3% to 15.1%, low for protein, energy, vitamin C, iron, vitamin B$_2$ (below 5%) but high for phosphorus, retinol, vitamin A, and $\beta$-carotene (over 10%). Age group, sex, and their interactions significantly influenced six nutrients (p < 0.05). Intake levels of zinc, vitamin B6, vitamin E, folate and cholesterol were not available in 2007 KNHANES but were calculated by CAN-Pro 3.0. Mean intake levels of zinc, vitamin B$_6$, vitamin E, and folate by age and sex groups revealed that some groups had mean levels below RI (Recommended Intake) or AI (Adequate Intake) levels. Intake level of cholesterol was higher than the recommended level (below 300 mg/day) in some groups, especially males. Results of the present study indicate the need for comparable and more comprehensive NDB to be used for dietary assessment of KNHANES and other researches. More rigorous evaluation of nutrients which have not been reported in KNHANES is needed.