• Title/Summary/Keyword: software system

Search Result 12,099, Processing Time 0.047 seconds

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

Harmonic Reduction Scheme By the Advanced Auxiliary Voltage Supply (개선된 보조전원장치에 의한 고조파 저감대책)

  • Yoon, Doo-O;Yoon, Kyoung-Kuk;Kim, Sung-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.759-769
    • /
    • 2015
  • Diode rectifiers are very popular in industry. However, they include large low-order harmonics in the input current and do not satisfy harmonic current content restrictions. To reduce the harmonics to the power system, several methods have been introduced. It is heavy and expensive solution to use passive filters as the solution for high power application. Another solution for the harmonic filter is utilization of active filter, but it is too expensive solution. Diode rectifiers with configurations using switching device have been introduced, but they are very complicated. The combined 12-pulse diode rectifier with the square auxiliary voltage supply has been introduced. It has the advantages that auxiliary circuit is simple and inexpensive compared to other strategies. The advanced auxiliary voltage supply in this thesis is presented as a new solution. When the square auxiliary voltage supply applied, the improvement of THD is 6~60[%] in whole load range. But when the advanced auxiliary voltage supply applied, it shows stable and excellent reduction effect of THD as 57~71[%]. Especially, for the case with 10[%] load factor, reduction effect of THD has little effect as 6[%] in the case of inserting a square auxiliary voltage supply. But when the proposed new solution applied, reduction effect has excellent effect as 71[%]. Theoretical analysis of the combined 12-pulse diode rectifier with the advanced auxiliary voltage supply is presented and control methods of the auxiliary supply is proposed. The reduction in the input current harmonics is verified by simulation using software PSIM.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Exception based Dynamic Service Coordination Framework for Web Services (웹 서비스를 위한 예외 상황 기반 동적 서비스 연결 프레임워크)

  • Han Dong-Soo;Lee Sung-Doke;Jung Jong-Ha
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.8
    • /
    • pp.668-680
    • /
    • 2006
  • Web services on the Internet are not always reliable in terms of service availability and performance. Dynamic service coordination capability of a system or an application invoking Web services is essential to cope with such unreliable situations. In dynamic service coordination, if a Web service does not respond within a specific time constraint, it is replaced with another Web service at run time for reliable invocation of Web services. In this paper, we develop an exception based dynamic service coordination framework for Web services. In the framework, all necessary information for dynamic service coordination is explicitly specified and summarized as a set of attributes. Then classes and workflows, supporting dynamic service coordination and invoking Web services, are automatically created based on these attributes. Developers of Web services client programs can make the invocations of Web services reliable by calling the methods of the classes. Some performance loss has been observed in the indirect invocation of a Web service. However, when we consider the flexibility and reliability gained from the method, the performance loss would be acceptable in many cases.

A Study on Evaluation System of Track Support Stiffness for Concrete Tracks (콘크리트궤도의 궤도지지강성 평가시스템에 관한 연구)

  • Choi, Jung-Youl;Kim, Man-Hwa;Kim, Hyun-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.535-541
    • /
    • 2020
  • A conventional elastic material replacement and performance evaluation are very complicated and time-consuming, and it is difficult to know when to replace the elastic material in advance. By comparing with the product limit and the functional limit, the necessity of elastic material replacement and the improvement of track support stiffness according to replacement can be immediately demonstrated based on experimental data. Using an evaluation system of track support stiffness, the performance evaluation data for elastic materials obtained through field tests using software for track support stiffness is integrated and managed on the administrator's computer. Therefore, the replacement plan is established and maintenance history is managed by identifying the replacement time and location of elastic materials. It is possible to evaluate the performance and condition of the elastic material at the various points during the working time of the track inspection and the track performance (track support stiffness) and durability of the elastic material (aging level, spring stiffness variation rate, etc.) at the operation condition. The elastic material could be replaced timely, and the deterioration of the elastic material can be continuously monitored.

A Encryption Technique of JPEG2000 Image Using 3-Dimensional Chaotic Cat Map (3차원 카오스 캣맵을 이용한 JPEG2000 영상의 암호화 기술)

  • Choi, Hyun-Jun;Kim, Soo-Min;Seo, Young-Ho;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.173-180
    • /
    • 2005
  • In this paper, we proposed the image hiding method which decreases calculation amount by encrypt partial data using discrete wavelet transform(DWT) and linear scale quantization which were adopted as the main technique for frequency transform in JPEG2000 standard. Also we used the chaotic system and cat map which has smaller calculation amount than other encryption algorithms and then dramatically decreased calculation amount. This method operates encryption process between quantization and entropy coding for preserving compression ratio of images and uses the subband selection method. Also, suggested encryption method to JPEG2000 progressive transmission. The experiments have been performed with the Proposed methods implemented in software for about 500 images. Consequently, we are sure that the proposed is efficient image encryption methods to acquire the high encryption effect with small amount of encryption. It has been shown that there exits a relation of trade-off between the execution time and the effect of the encryption. It means that the proposed methods can be selectively used according to the application areas.

Integrated Parallelization of Video Decoding on Multi-core Systems (멀티코어 시스템에서의 통합된 비디오 디코딩 병렬화)

  • Hong, Jung-Hyun;Kim, Won-Jin;Chung, Ki-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.7
    • /
    • pp.39-49
    • /
    • 2012
  • Demand for high resolution video services leads to active studies on high speed video processing. Especially, widespread deployment of multi-core systems accelerates researches on high resolution video processing based on parallelization of multimedia software. Previously proposed parallelization approach could improve the decoding performance. However, some parallelization methods did not consider the entropy decoding and others considered only a partial decoding parallelization. Therefore, we consider parallel entropy decoding integrated with other parallel video decoding process on a multi-core system. We propose a novel parallel decoding method called Integrated Parallelization. We propose a method on how to optimize the parallelization of video decoding when we have a multi-core system with many cores. We parallelized the KTA 2.7 decoder with the proposed technique on an Intel i7 Quad-Core platform with Intel Hyper-Threading technology and multi-threads scheduling. We achieved up to 70% performance improvement using IP method.

6TALK : Implementation of NAT-PT/SIIT and enhanced ALG

  • 이주철;호용근;신명기;김형준
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.701-705
    • /
    • 2002
  • This paper describes implementation of IPv6-IPv4 transition toolbox named as 6TALK(IPv6 TrAansLator of Krv6) and some scenarios using 6TALK which enables IPv6 island to connect other IPv6 island or IPv4 island seamlessly. 6TALK implements some transition mechanisms suggested in NGTrans Working Group of IETF. Those mechanisms are composed of basic mechanism, tunneling, and applied mechanism such as DSTM. 6TALK provides functions which enable IPv6 network at the edge of existing network to communicate with IPv4 network by using these transition mechanisms. As major transition mechanisms in 6TALK we adopt NAT-PT/SIIT and DSTM/DSTM options and as implementation environment we use Linux Kernel 2.4.18 and Netfilter framework. Software modules implemented in Linux kernel was ported to hardware box using Motorola MPC 8260 processor. The transition mechanisms used in 6TALK are the ones predicted to be used in initial transition step to IPv6.

  • PDF

Development of Sensor Network Simulator for Estimating Power Consumption and Execution Time (전력소모량 및 실행시간 추정이 가능한 센서 네트워크 시뮬레이터의 개발)

  • Kim, Bang-Hyun;Kim, Tae-Kyu;Jung, Yong-Doc;Kim, Jong-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.1
    • /
    • pp.35-42
    • /
    • 2006
  • Sensor network, that is an infrastructure of ubiquitous computing, consists of a number of sensor nodes of which hardware is very small. The network topology and routing scheme of the network should be determined according to its purpose, and its hardware and software may have to be changed as needed from time to time. Thus, the sensor network simulator being capable of verifying its behavior and estimating performance is required for better design. Sensor network simulators currently existing have been developed for specific hardwares or operating systems, so that they can only be used for such systems and do not provide any means to estimate the amount of power consumption and program execution time which are major issues for system design. In this study, we develop the sensor network simulator that can be used to design and verify various sensor networks without regarding to types of applications or operating systems, and also has the capability of predicting the amount of power consumption and program execution time. For this purpose, the simulator is developed by using machine instruction-level discrete-event simulation scheme. As a result, the simulator can be used to analyze program execution timings and related system behaviors in the actual sensor nodes in detail. Instruction traces used as workload for simulations are executable images produced by the cross-compiler for ATmega128L microcontroller.

  • PDF

Evaluation of TiN-Zr Hydrogen Permeation Membrane by MLCA (Material Life Cycle Assessment) (물질전과정평가(MLCA)를 통한 TiN-Zr 수소분리막의 환경성 평가)

  • Kim, Min-Gyeom;Son, Jong-Tae;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.9-14
    • /
    • 2018
  • In this study, Material life cycle evaluation was performed to analyze the environmental impact characteristics of TiN-Zr membrane manufacturing process. The software of MLCA was Gabi. Through this, environmental impact assessment was performed for each process. Transition metal nitrides have been researched extensively because of their properties. Among these, TiN has the most attention. TiN is a ceramic materials which possess the good combination of physical and chemical properties, such as high melting point, high hardness, and relatively low specific gravity, high wear resistance and high corrosion resistance. With these properties, TiN plays an important role in functional materials for application in separation hydrogen from fossil fuel. Precursor TiN was synthesized by sol-gel method and zirconium was coated by ball mill method. The metallurgical, physical and thermodynamic characteristics of the membranes were analyzed by using Scanning Electron Microscope (SEM), Energy Dispersive X-ray (EDS), X-ray Diffraction (XRD), Thermo Gravimetry/Differential Thermal Analysis (TG/DTA), Brunauer, Emmett, Teller (BET) and Gas Chromatograph System (GP). As a result of characterization and normalization, environmental impacts were 94% in MAETP (Marine Aquatic Ecotoxicity), 2% FAETP (Freshwater Aquatic Ecotoxicity), 2% HTP (Human Toxicity Potential). TiN fabrication process appears to have a direct or indirect impact on the human body. It is believed that the greatest impact that HTP can have on human is the carcinogenic properties. This shows that electricity use has a great influence on ecosystem impact. TiN-Zr was analyzed in Eco-Indicator '99 (EI99) and CML 2001 methodology.