• Title/Summary/Keyword: software reliability

Search Result 1,524, Processing Time 0.03 seconds

QSAR Approach for Toxicity Prediction of Chemicals Used in Electronics Industries (전자산업에서 사용하는 화학물질의 독성예측을 위한 QSAR 접근법)

  • Kim, Jiyoung;Choi, Kwangmin;Kim, Kwansick;Kim, Dongil
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.2
    • /
    • pp.105-113
    • /
    • 2014
  • Objectives: It is necessary to apply quantitative structure activity relationship (QSAR) for the various chemicals with insufficient toxicity data that are used in the workplace, based on the precautionary principle. This study aims to find application plan of QSAR software tool for predicting health hazards such as genetic toxicity, and carcinogenicity for some chemicals used in the electronics industries. Methods: Toxicity prediction of 21 chemicals such as 5-aminotetrazole, ethyl lactate, digallium trioxide, etc. used in electronics industries was assessed by Toxicity Prediction by Komputer Assisted Technology (TOPKAT). In order to identify the suitability and reliability of carcinogenicity prediction, 25 chemicals such as 4-aminobiphenyl, ethylene oxide, etc. which are classified as Group 1 carcinogens by the International Agency for Research on Cancer (IARC) were selected. Results: Among 21 chemicals, we obtained prediction results for 5 carcinogens, 8 non-carcinogens and 8 unpredictability chemicals. On the other hand, the carcinogenic potential of 5 carcinogens was found to be low by relevant research testing data and Oncologic TM tool. Seven of the 25 carcinogens (IARC Group 1) were wrongly predicted as non-carcinogens (false negative rate: 36.8%). We confirmed that the prediction error could be improved by combining genetic toxicity information such as mutagenicity. Conclusions: Some compounds, including inorganic chemicals and polymers, were still limited for applying toxicity prediction program. Carcinogenicity prediction may be further improved by conducting cross-validation of various toxicity prediction programs, or application of the theoretical molecular descriptors.

A Models of Economic Analysis in Safety Diagnosis for Remodeling Strategies of Apartment Housing (공동주택의 리모델링 전략을 위한 안전진단의 경제성분석 모델)

  • Seo Kwang-Jun;Choi Mi-Ra;Shin Nam-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.4 s.26
    • /
    • pp.164-171
    • /
    • 2005
  • The importance of the life cycle cost analysis(LCCA) for apartment housing remodeling projects has been fully recognized over the last decade. Accordingly theoretical models, guidelines, and supporting software systems were developed for the life cycle cost analysis of apartment housing remodeling systems. However, the level of consensus on LCCA results is still low due to the lack of reliable data on remodeling activities for safety diagnosis. in order to predict the reliability based LCCA of the given case, suggested the remodeling strategies level after reviewing other related materials. Apply the real information of the economic index. And based on such analytical measures, remodeling and operation cost and LCC in remodeling strategies level have been predicted; suggests the basic information about remodeling interventions level for the apartment housing. The LCC analysis models and the fuzzy logic based safety assessment presented in this study can greatly contribute to the value-oriented design alternative selection, estimation of the economic analysis, and the allocation of budget for apartm.

Design and Implementation of XML Document Transformation System based on Structured Differences Analysis (구조적 상이성 분석에 기반한 XML 문서 변환 시스템의 설계 및 구현)

  • Jo, Jeong-Gil;Jo, Yun-Gi;Gu, Yeon-Seol
    • The KIPS Transactions:PartD
    • /
    • v.9D no.2
    • /
    • pp.297-306
    • /
    • 2002
  • This paper handles the design and implementation of the system for transforming the XML document bated on XML Schema being different in syntax but similar in logic, with using structured differences analysis. In the system, the merge data is generated from the source and destination documents by utilizing data registry and structured differences analysis, and then XML document is generated from the generated merge data. The XML document transformation system is designed that transformation process to the present application system from the different application system gains advantage in the aspect of time, cost, and reliability. The implementation environment of the system is that it is run on IBM compatible PC and it is developed using the software of visual basic 6.0 with the Platform of Windows 2000.

Accuracy of virtual models in the assessment of maxillary defects

  • Kamburoglu, Kivanc;Kursun, Sebnem;Kilic, Cenk;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

Flexural strengths of implant-supported zirconia based bridges in posterior regions

  • Rismanchian, Mansour;Shafiei, Soufia;Nourbakhshian, Farzaneh;Davoudi, Amin
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.346-350
    • /
    • 2014
  • PURPOSE. Impact forces in implant supported FDP (fixed dental prosthesis) are higher than that of tooth supported FDPs and the compositions used in frameworks also has a paramount role for biomechanical reasons. The aim of this study was to evaluate the flexural strength of two different zirconia frameworks. MATERIALS AND METHODS. Two implant abutments with 3.8 mm and 4.5 mm platform were used as premolar and molar. They were mounted vertically in an acrylic resin block. A model with steel retainers and removable abutments was fabricated by milling machine; and 10 FDP frameworks were fabricated for each Biodenta and Cercon systems. All samples were thermo-cycled for 2000 times in $5-55^{\circ}C$ temperature and embedded in $37^{\circ}C$ artificial saliva for one week. The flexural test was done by a rod with 2 mm ending diameter which was applied to the multi-electromechanical machine. The force was inserted until observing fracture. The collected data were analyzed with SPSS software ver.15, using Weibull modulus and independent t-test with the level of significance at ${\alpha}=.05$. RESULTS. The mean load bearing capacity values were higher in Biodenta but with no significant differences (P>.05). The Biodenta frameworks showed higher load bearing capacity ($F_0=1700$) than Cercon frameworks ($F_0=1520$) but the reliability (m) was higher in Cercon (m=7.5). CONCLUSION. There was no significant difference between flexural strengths of both zirconia based framework systems; and both Biodenta and Cercon systems are capable to withstand biting force (even parafunctions) in posterior implant-supported bridges with no significant differences.

Implementation of Real-Time Channel Module for Applying Wireless Communication Environments (무선 통신 환경 적용이 가능한 실시간 채널 모듈 구현)

  • Park, Chan Ju;Kim, Woojoong;Jang, Byung-Jun;Yoon, Hyungoo;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.438-444
    • /
    • 2016
  • In this paper, A real-time channel module which can apply the wireless propagation channel was developed using USRP and Lab-VIEW. When the proposed channel module is used in conjunction with the implemented HW(hardware) simulators for cognitive radio and frequency interference analysis and so on, it can increase the reliability about wireless propagation environments. In addition, the proposed module overcomes the limit of existing HW simulator that data transfer rate is limitative in communication system through the design of the inner parts. Along with this, it is possible to apply channel parameters necessary to estimate the easier communication performance. Also, this has the advantage that it can be flexibly applied in implementing the communication channel with the upcoming new scenarios. The proposed module can estimate the communication performance via constellation and BER using the implemented module.

Intra- and Inter-rater Reliabilities of Infrasternal Angle Measurement

  • Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.154-158
    • /
    • 2015
  • Purpose: The purpose of this study was to propose a new reference point for measurement of the infrasternal angle and to investigate the intra- and inter-rater reliabilities of infrasternal angle measurement using photographs. Methods: Twenty-four healthy male college students participated as subjects in this study. Photographs were taken of subjects in two postures, one standing with the shoulders relaxed and one standing with the shoulders at $150^{\circ}$ abduction. All photographs were analyzed using Image J software. Raters used the photographs to measure the infrasternal angle between the xiphoid process, the medial margin of rib and navel on the right and left sides. The reliability of the infrasternal angle measurement was assessed by means of intraclass correlation coefficients [ICC (3,1)]. The level of statistical significance was set at p<0.05. Results: The intra- and inter-rater reliabilities of the infrasternal angle measurement for the right side at rest were excellent (ICC=0.866 and 0.813, respectively), as were those for the left side at rest (ICC=0.919 and 0.846, respectively). At $150^{\circ}$ shoulder abduction, the intra- and inter-rater reliabilities for measurement of the infrasternal angle on the right side were excellent (ICC=0.972 and 0.778, respectively), as were those for the left side (ICC=0.914 and 0.826, respectively). Conclusion: These findings suggest that this technique can be successfully used to measure the infrasternal angle, thus suggesting a new reference point for determining the length of the internal oblique and external oblique muscles in clinical situations.

Analysis of Stress Distribution around a Central Crack Tip in a Tensile Plate Using Phase-Shifting Photoelasticity and a Power Series Stress Function (위상이동 광탄성법과 멱급수형 응력함수를 이용한 인장시편 중앙 균열선단 주위 응력장 해석)

  • Baek, Tae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • This paper presents stress distribution around a central crack tip in a tensile plate using phase-shifting photoelasticity and a power series stress function. Isochromatic data along the straight lines far from the crack tip were obtained by phase shifting photoelasticity and were used as input data of the hybrid experimental analysis. By using the complex-type power series stress equations, the photoelastic stress distribution fields in the vicinity of the crack and the mode I stress intensity factor were obtained. With the help of image processing software, accuracy and reliability was enhanced by twice multiplying and sharpening the measured isochromatics. Actual and reconstructed fringes were compared qualitatively. For quantitative comparison, percentage errors and standard deviations of the percentage errors were calculated for all measured input data by varying the number of terms in the stress function. The experimental results agreed with those predicted by finite element analysis and empirical equation within 2 percent error.

Empirical study on the influence of emotional leadership on business performance in the fashion industry - Focused on the moderating effects of organizational culture - (패션기업 CEO의 감성적 리더십이 기업성과에 미치는 영향 - 조직문화의 조절효과 연구 -)

  • Kim, Sook-Hee;Yang, Dong-Woo
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.6
    • /
    • pp.1004-1020
    • /
    • 2015
  • The purpose of this study is to assess whether the emotional leadership of the CEO of a fashion company has a significant influence on corporate performance. In this study, a survey was conducten on employees of fashion companies from August 1 to 30, 2015, and 350 copies of questionnaires were collected and used for analysis. Factor analysis, reliability analysis, and regression analysis were employed to analyze the data using SPSS software (ver. 21.0). According to the study results, if a fashion company CEO has higher emotional leadership, it leads to an increase in the job satisfaction and performance of the staff members, and an improvement in new product performance thanks to more investment and development and an expanded R&D staff. Additionally, the higher emotional leadership of the CEO contributes to an increase in operating profits, sales, and market share. Therefore, the importance of organizational culture was confirmed by its regulation effect on the emotional leadership and management performance of a fashion company. According to the results of this study, the emotional leadership of a CEO plays an important role in improving the performance of a fashion company, and future studies are needed to identify how to enhance the corporate performance of a fashion company from various perspectives.

Free Vibration Characteristics of 5 × 5 Spacer Grid Assembly Supporting the PWR Fuel Rod (경수로 연료봉을 지지하는 5×5 지지격자체의 자유진동특성)

  • 강흥석;윤경호;송기남;최명환
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.6
    • /
    • pp.512-519
    • /
    • 2004
  • This paper described the free vibration characteristics of Optimized H Type (OHT) spacer grids (SG) supporting the PWR fuel rod. The vibration test and the finite element (FE) analysis are performed under the free boundary condition and the clamped at two points (or three points) in the bottom which is the same one as the experimental condition for the dummy rod continuously supported by spacer grids. A modal test is conducted by the impulse excitation method using an impulse hammer and an accelerometer, and the TDAS module of the I-DEAS software is used to acquire and analyze the sensor signals. The softwares related to the FE analysis are the I-DEAS for the geometrical shape modeling and meshing, and the ABAQUS for solving. The fundamental frequency of the OHT SG by experiment under a clamped condition at two points is 175.18 Hz, and shows a bending mode. We think there is no resonance between the fuel rod and the SG because the SG's frequency is higher than that of the fuel rod existing in the range from 30 to 120 Hz. The fundamental frequency of the SG under the free boundary condition is 349.2 Hz showing a bending mode, and the results between the test and the analysis have a good agreement with maximum 7 % in error It is also found that the FE analysis model of the OHT SGs to analyze an impact, a buckling and vibration et al. has been generated with reliability.