• Title/Summary/Keyword: software error

Search Result 1,344, Processing Time 0.03 seconds

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Stereo Disparity Estimation by Analyzing the Type of Matched Regions (정합영역의 유형분석에 의한 스테레오 변이 추정)

  • Kim Sung-Hun;Lee Joong-Jae;Kim Gye-Young;Choi Hyung-Il
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.1
    • /
    • pp.69-83
    • /
    • 2006
  • This paper describes an image disparity estimation method using a segmented-region based stereo matching. Segmented-region based disparity estimation yields a disparity map as the unit of segmented region. However, there is a problem that it estimates disparity imprecisely. The reason is that because it not only have matching errors but also apply an identical way to disparity estimation, which is not considered each type of matched regions. To solve this problem, we proposes a disparity estimation method which is considered the type of matched regions. That is, the proposed method classifies whole matched regions into similar-matched region, dissimilar-matched region, false-matched region and miss-matched region by analyzing the type of matched regions. We then performs proper disparity estimation for each type of matched regions. This method minimizes the error in estimating disparity which is caused by inaccurate matching and also improves the accuracy of disparity of the well-matched regions. For the purpose of performance evaluations, we perform tests on a variety of scenes for synthetic, indoor and outdoor images. As a result of tests, we can obtain a dense disparity map which has the improved accuracy. The remarkable result is that the accuracy of disparity is also improved considerably for complex outdoor images which are barely treatable in the previous methods.

A Study on the Development of Text Communication System based on AIS and ECDIS for Safe Navigation (항해안전을 위한 AIS와 ECDIS 기반의 문자통신시스템 개발에 관한 연구)

  • Ahn, Young-Joong;Kang, Suk-Young;Lee, Yun-Sok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.4
    • /
    • pp.403-408
    • /
    • 2015
  • A text-based communication system has been developed with a communication function on AIS and display and input function on ECDIS as a way to complement voice communication. It features no linguistic error and is not affected by VHF restrictions on use and noise. The text communication system is designed to use messages for clear intentions and further improves convenience of users by using various UI through software. It works without additional hardware installation and modification and can transmit a sentence by selecting only via Message Banner Interface without keyboard input and furthermore has a advantage to enhance processing speed through its own message coding and decoding. It is determined as the most useful alternative to reduce language limitations and recognition errors of the user and solve the problem of various voice communications on VHF. In addition, it will help to prevent collisions between ships with decrease in VHF use, accurate communication and request of cooperation based on text at heavy traffic areas.

Seismic Displacement Analysis of GPS Permanent Stations in Korean and Asian Area Due to the Tohoku-Oki Mega-Thrust Earthquake (일본 Tohoku-Oki 대지진으로 인한 한국 및 아시아 지역 상시관측소의 위치변동량 분석)

  • Hwang, Jin-Sang;Yun, Hong-Sic;Lee, Dong-Ha;Jung, Tae-Jun;Suh, Yong-Cheol
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.137-149
    • /
    • 2011
  • In this study, we analyzed the effects of seismic displacements due to the mega thrust earthquake occurred near Tohoku-Oki area on Mar. 11, 2011 with Mw 9.0 magnitude in the context of evaluation of position change by the earthquake on the Korean and Asian GPS permanent stations. For this, two weeks GPS data observed around the event of Tohoku-Oki earthquake (Mar. 4 ~ Mar. 18, 2011) were obtained from 22 GPS permanent stations in the vicinity of epicenter (Korea, Japan, Russia, China and Taiwan) and 284 IGS global stations. All available GPS data were processed and adjusted by GAMIT/GLOBK software to estimate the co-seismic horizontal displacements at each station. As the results of GPS analysis, the co-seismic displacements due to Tohoku-Oki earthquake were clearly revealed in the GPS stations of Asian region, Japan and its neighboring countries, and even to affect the horizontal position of GPS station (WUHN in China) which are located about 2,702km away from the epicenter. In conclusion, it was found that the Tohoku-Oki earthquake had resulted in the horizontal displacements ranging from 14.9 mm to 58.3 mm in Korea. So, these displacements can cause the position error of GPS geodetic survey up to 20 mm without updating the coordinates of Korean geodetic network.

Construction of a reference stature growth curve using spline function and prediction of final stature in Korean (스플라인 함수를 이용한 한국인 키 기준 성장 곡선 구성과 최종 키 예측 연구)

  • An, Hong-Sug;Lee, Shin-Jae
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.16-28
    • /
    • 2007
  • Objective: Evaluation of individual growth is important in orthodontics. The aim of this study was to develop a convenient software that can evaluate current growth status and predict further growth. Methods: Stature data of 2 to 20 year-old Koreans (4893 boys and 4987 girls) were extracted from a nationwide data. Age-sex-specific continuous functions describing percentile growth curves were constructed using natural cubic spline function (NCSF). Then, final stature prediction algorithm was developed and its validity was tested using longitudinal series of stature measurements on randomly selected 200 samples. Various accuracy measurements and analyses of errors between observed and predicted stature using NCSF growth curves were performed. Results: NCSF growth curves were shown to be excellent models in describing reference percentile stature growth curie over age. The prediction accuracy compared favorably with previous prediction models, even more accurate. The current prediction models gave more accurate results in girls than boys. Although the prediction accuracy was high, the error pattern of the validation data showed that in most cases, there were a lot of residuals with the same sign, suggestive of autocorrelation among them. Conclusion: More sophisticated growth prediction algorithm is warranted to enhance a more appropriate goodness of model fit for individual growth.

A Design for Realtime Monitoring System and Data Analysis Verification TA to Improve the Manufacturing Process Using HW-SW Integrated Framework (HW-SW 통합 프레임워크를 활용한 제조공정 개선을 위한 실시간 모니터링 시스템과 데이터 분석검증 TA설계)

  • Kim, Jae Chun;Jin, Seon A;Park, Young Hee;Noh, Seong Yeo;Lee, Hyun Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.357-370
    • /
    • 2015
  • Massive data occurred in a manufacturing place is able to fulfill very important roll to improve the manufacturing process. Domestic manufacturing business has been making an multilateral effort to react the change of manufacturing circumstance, but it undergoes many difficulties due to technical weakness. Coatings is a type of paint. It protect products by forming a film layer on the products and assigns various properties to those. The research of coatings is one of the fields studied actively in the polymer industry. The importance of the coatings in various industries is more increased. However, the industry still performs a mixing process in dependence on operator's experiences. In this paper, we propose a design for realtime monitoring system and data analysis verification TA to improve the manufacturing process using HW-SW integrated framework. Analysis results from the proposed framework are able to improve the coatings formulation process by collecting more quantitative reference data for work and providing it to work place. In particular, the framework may reduce the deterioration and loss cost which are caused by absence of a standard data as a accurate formulation criteria. It also may suggest a counterplan regarding errors which can be occurred in the future by deriving a standard calibration equation from the analysis using R and Design of Experiments about an error data generated in the mixing step.

Comparison and Examination of the Calculating Hydrological Geographic Parameters Using GIS (GIS를 이용한 수문학적 지형인자 산정에 대한 비교검토)

  • Kim, Kyung-Tak;Choi, Yun-Seok;Lee, Hyo-Jung
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.1
    • /
    • pp.25-39
    • /
    • 2010
  • Recently, GIS softwares such as WMS, ArcHydro, and HyGIS which can calculate hydrological geographic parameters are popularized. These softwares have the functions to calculate various geographic parameters which are used in water resources from DEM (Digital Elevation Model). In this study, hydrological geographic parameters calculated by WMS and ArcHydro are compared and examined with them from HyGIS to evaluate the applicability of the parameters from HyGIS. Bochungcheon (Riv.), Wicheon (Riv.), Pyungchanggang (Riv.), Gyungancheon (Riv.), Naerincheon (Riv.), and Imjingang (Riv.) watersheds are selected for this study, and the shape of watershed, watershed area, watershed slope, the average slope of watershed, main stream length, main stream slope, maximum flow distance, and the slope of maximum flow distance are calculated to compare and examine the characteristics. Study results show that the average relative error of 7 geographic parameters from all the watersheds is 4.77 %, and all the watershed boundaries are very similar. So, all the geographic parameters calculated by each software show very similar value, and the geographic parameters calculated by HyGIS can be applied to water resources with WMS and ArcHydro which have been generally used.

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Prediction of the content of white clover and perennial ryegrass in fresh or dry mixtures made up from pure botanical samples, by near infrared spectroscopy

  • Blanco, Jose A.;Alomar, Daniel J.;Fuchslocher, Rita I.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1266-1266
    • /
    • 2001
  • Pasture composition, an important attribute determining sward condition and value, is normally assessed by hand separation, drying and measuring weight contribution of each species in the mixture. This is a tedious, time and labour consuming procedure. NIRS has demonstrated the potential for predicting botanical composition of swards, but most of the work has been carried out on dry samples. The aim of this work was to evaluate the feasibility of developing NIR models for predicting the white clover and ryegrass content in fresh or dry mixtures artificially prepared from pure samples of both species. Mixtures from pure stands of white clover(Trifolium repens) and perennial ryegrass (Lolium perenne) were prepared with different proportions (0 to 100%) of each species (fresh weight). A total of 55 samples were made (11 mixtures,5 cuts). Spectra (400 to 2500 nm) were taken from fresh chopped (rectangular cuvettes, transport sample module) samples, in a NIR Systems 6500 scanning monochromator controlled by the software NIRS 3 (Infrasoft International), which was also utilized for calibration development. Different math treatments (derivative order, subtraction gap and smooth segment) and a scatter correction treatment of the spectra (SNV and Detrend) were tested. Equations were developed by modified partial least squares. Prediction accuracy evaluated by cross-validation, showed that percentage of clover or ryegrass, as contribution in dry weight, can be successfully percentage of clover or ryegrass, as contribution in dry weight, can be successfully predicted either on fresh or dried samples, with equations developed by different math treatments. Best equations for fresh samples were developed including a first, second, or third derivative, whereas for dry samples best equations included a second or third derivative. Standard errors of ross validation were about 6% for fresh and 3.6% for dry samples, Coefficient of determination of cross validation (1-VR) were over 0.95 times the value of SECV for fresh samples and over 8 times the value of SECV for dry samples. Scatter correction (SNV and Detrend) in general improved prediction accuracy. It is concluded more precise on dried and ground samples, it can be used with an acceptable error level and less time and labour, on fresh samples.

  • PDF

Finite Element Analysis in Finite Length Bar under Constant Amplitude Loading (일정진폭하중을 받는 유한 길이 봉의 유한요소해석)

  • Hwang, Eun-Ha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.525-533
    • /
    • 2010
  • Direct time integration method such as Newmark method is numerically performed under the assumption that continuous load function such as constant amplitude load can be treated as a discontinuous load fuction. It is due that the load can be treated as a constant value at the given time period regardless of variation of load at the time increment interval. It means the numerical results should be accompanied by the error due to approximation of load fuction. In contrast, the load function is calculated by convolution integral for the given time interval at finite element equation based on Gurtin's variation equation. Therefore. precise numerical results can be obtained by Gurtin's method because of convolution integral for the continuous load fuction curve even at the variation of load function in the given time interval. In this study, we prove that Gurtin's method can be more suitable than Newmark method in the problem of constant amplitude loading, using the numerical results for the free end of the one-dimensional rod. This study also shows that Gurtin's method is more effective in constant amplitude loading than in constant loading. The accuracy and the validity are verified by comparison between the results of in-house FORTRAN code and ADINA, a commercial software supporting Newmark method.