• Title/Summary/Keyword: soft k-product

Search Result 148, Processing Time 0.027 seconds

A Study on the Characteristics of Liquid Body Foam Which Added the Garlic Extract (갈릭 추출물을 첨가한 액상 바디 폼의 특성에 관한 연구)

  • Sung, Ki-Chun;Ahn, Beom-Shu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.285-291
    • /
    • 2001
  • The liquid body foam which added the garlic extract, differs for clothes and kitchen detergent, industrial and domestic detergent, and it has various characteristics as a soft detergent for bath and hair product. The contents of various characteristics in this experiment have tested for the foam formation force, the moisture force and the antimicrobial force. In case of this product adding garlic extrat, we could know the three characteristics. In first case to increase the concentration of Sunfom-S, we could know that the foam formation force increases following to it. In second case to increase the concentration of propylene glycol, we could know that the moisture force increases following to moisturing agent. In third case to increase the concentration of garlic extract, we could know that the antibiosis and preservation efficacy appears between 3.0-4.0wt% and the sterilization efficacy appears more than 5.0wt%. According to the result of this experiment, we could recognize the characteristics concerning to quality of this product.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Low-Power ECG Detector and ADC for Implantable Cardiac Pacemakers (이식형 심장 박동 조율기를 위한 저전력 심전도 검출기와 아날로그-디지털 변환기)

  • Min, Young-Jae;Kim, Tae-Geun;Kim, Soo-Won
    • Journal of IKEEE
    • /
    • v.13 no.1
    • /
    • pp.77-86
    • /
    • 2009
  • A wavelet Electrocardiogram(ECG) detector and its analog-to-digital converter(ADC) for low-power implantable cardiac pacemakers are presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. To achieve high-detection performance with low-power consumption, the multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited. To further reduce the power dissipation, a low-power ADC, which is based on a Successive Approximation Register(SAR) architecture with an on/off-time controlled comparator and passive sample and hold, is also presented. Our algorithmic and architectural level approaches are implemented and fabricated in standard $0.35{\mu}m$ CMOS technology. The testchip shows a good detection accuracy of 99.32% and very low-power consumption of $19.02{\mu}W$ with 3-V supply voltage.

  • PDF

Fast and Soft Functionalization of Carbon Nanotube with -SO3H, -COOH, -OH Groups for Catalytic Hydrolysis of Cellulose to Glucose

  • Lusha, Qin;Lee, Sungho;Li, Oi Lun
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.3
    • /
    • pp.87-94
    • /
    • 2020
  • Herein, sulfonated carbon nanotubes (CNT) have been prepared in dilute sulfuric acid (H2SO4) via a novel sulfonation approach based on gas-liquid interfacial plasma (GLIP) at room temperature. The sulfonic acid groups and total acid groups densities of CNT after GLIP treatment in 2 M H2SO4 for 45 min can reach to 0.53 mmol/g and 3.64 mmol/g, which is higher than that of sulfonated CNT prepared under 0.5 M / 1 M H2SO4. The plasma sulfonated CNT has been applied as catalysts for the conversion of microcrystalline cellulose to glucose. The effect of hydrolysis temperature and hydrolysis time on the conversion rate and product distribution have been discussed. It demonstrates that the total conversion rate of cellulose increasing with hydrolysis temperature and hydrolysis time. Furthermore, the GLIP sulfonated CNT prepared in 2 M H2SO4 for 45 min has shown high catalytic stability of 85.73 % after three cycle use.

A Study on Development of Conceptual Model in Consumer Product Safety Policy(CPSPcon) using the SSM approach (SSM을 활용한 공산품 안전정책분야의 개념모델(CPSPcon) 개발에 관한 연구)

  • Lee, Jun-Soo;Bea, Jin-Han;Kim, Hong-Won;Song, Jae-Bin
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.33-42
    • /
    • 2012
  • This paper dealt with developing conceptual model for making public policy on consumer product safety. The matters of consumer safety, public health and environmental protection are essential parts of making policy for consumer products. Moreover, policy authority should consider all measures based on consumer safety. In the process making regulations, policy authority has to have some methods to prevent errors on treating eligible persons as persons disqualified under uncertainty decision making of public policy. To recognize and ensure fairness on public policy, policy authority needs to establish basic policy making and fundamental concepts. Therefore, we developed conceptual model for consumer products safety, CPSPcon in this paper. The conceptual model is one part of SSM(Soft System Methodology) and can support specific policy target. The CPSPcon model can assist in evaluation of responses to an adapting or considering model.

Astudy On The Size, Characteristics And The Shape Of $Dentichek^{(R)}$ Toothbrush (($Denticheck^{(R)}$) 치솔의 규격, 특성 및 행태에 관한 연구)

  • Mun, Ik-Sang;Kim, Chong-Kwan;Chai, Jung-Kui;Jo, Kyoo-Sung;Choi, Seong-Ho;Yi, Seung-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.255-265
    • /
    • 1996
  • The purpose of the present study is to evaluate dimensional consistency, bristle finishes and bristle rebound rate of four brands of $Dentichek^{(R)}$ toothbrushes(regular-male, regular-female, soft-male, soft-female) to provide referneces in product enhancement and quality control for the manufacturer and to provide suggestions in selecting appropriate toothbrushes for general public. The results are as follows : 1. The size of the head is : $25.10{\times}8.10mm$ for male toothbrushes and $19.90{\times}8.10mm$ for male toothbrushes, while the size of the bristle portion is: $29.90{\times}10.65mm$ for male toothbrushes and $25.25{\times}10.65mm$ for female toothbrushes. 2. The length of the bristles is 10.70mm in all four groups. 3. The length of the toothbrush is 192mm in all four groups. 4. The number of tuft is 43 for male toothbrushes and 35 for female toothbrushes. Tuft arrangement is 4-row configuration in all four groups. 5. The number of bristles in a tuft ranges from 40-56, with higher numbers in male toothbrushes compared to the female counterparts, and higher numbers in the "soft" variety compared to the regular ones. 6. The diameter of the bristle is : 0.21mm for the outer row and 0.19mm for the inner row in the regular brand, and 0.17mm for the soft brand. 7. Irregularly finished bristle ends comprised 20-22% of the total bristles. 8. The bristle rebound rate ranges from 55.9% to 62.3%, with higher numbers in the "soft" variety compared to the regular ones. The above results show that $Dentichek^{(R)}$ toothbrushes meet the requirements of Korean Dental Association standards for toothbrushes, but further evaluations of their effects on periodontium and plaque elimination in actual in-use situation may be needed.

  • PDF

APPLICATION OF THERMOFORMED APPLIANCES IN PEDIATRIC DENTISTRY (소아치과 임상에서의 Thermoformed Appliance의 적용)

  • Kim, Shin;Jeong, Tae-Sung;Yang, Chul-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.539-544
    • /
    • 1998
  • Thermoformed appliance, which has been recently introduced for dental usage, is an appliance made of thermoformed sheets and formed with positive or negative pressure under heat. Thermoplastic material is a kind of plastics and can be repeatedly softened by heat. It is classified into hard elastic foil, hard/soft compound foil and soft elastic foil, including BIOPLAST, BIOCRYL, IMPRELON, etc. It has been developed in 1969 and is available in various thickness, shape and color. There are two types of Vacuum former for thermoplastic materials; the pressure type and suction type. The former is much better than the latter for fabrication of various appliances due to its higher pressure. The authors have applied these appliances to some cases - chin cap, active retainer, individual Fluoride tray, mouth protector, bracket transfer mask, bruxism splint(night guard), Essix appliance - by pressure type Vacuum former($Biostar^{(R)}$). The thermoplastic appliances have numerous advantages such as simple procedure, short working time, clean and transparent product, less objectionable taste. But its outstanding advantage would be its excellent biocompatibility bacause it has no monomer and hence no tissue irritation. Although there is some limitations in its usage, it can be used widely for various purposes especaily for pediatric dentistry.

  • PDF

A Study on the Pile Material Suited for Pile Supported Embankment Reinforced by Geosynthetics (토목섬유로 보강된 성토지지말뚝 구조에 적합한 말뚝재료의 개발)

  • Choi, Choong-Lak;Lee, Kwang-Wu;Kim, Eun-Ho;Jung, Ji-Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.21-35
    • /
    • 2016
  • It is a current trend that the concrete track is applied for high speed railway. In the case of the railway embankment constructed on soft ground, the damage to concrete track which is sensitive to settlement such as distortion and deflection could be caused by very small amount of long term settlement. Pile Supported Embankment method can be considered as the effective method to control the residual settlement of the railway embankment on soft ground. The Geosynthetics is used inside of the embankment to maximize the arching effect transmitting the load of the embankment to the top of the piles. But, PHC piles that are generally used for bridge structures are also applied as the pile supporting the load of embankment concentrated by the effect of the Geosynthetics. That is very low efficiency in respect of pile material. So, in this study, the cast in place concrete pile was selected as the most suitable pile type for supporting the embankment by a case study and the optimum mixing condition of concrete using a by-product of industry was induced by performing the mixing designs and the compressive strength designs. And it is shown that the cast in place pile with the optimum mixing condition using the by-product of industry is 2.8 times more efficient than the PHC pile for the purpose of Pile Supported Embankment by the finite element analysis method.

Quality Characteristics of Jeolpyun Containing Baekbokryung (White Poria cocos Wolf) Powder Based on Water Content (수분 첨가량을 달리한 백복령 가루 첨가 절편의 품질특성)

  • Lee, Kyoung-Hee;Park, Jung-Eun;Jang, Myung-Sook
    • Korean journal of food and cookery science
    • /
    • v.24 no.3
    • /
    • pp.282-293
    • /
    • 2008
  • The purpose of this study was to acquire basic data on Jeolpyun added with Baekbokryung powder to aid the product's commercial production. Initially a sensory test was performed with consumers to the identify preferred amount of Baekbokryung powder to add according to age. The results revealed that those in their 20's to 40's preferred the 3% treatment, while those 50 and older preferred the 5% treatment. Next, the optimum water content of Jeolpyun was chosen by examining select quality characteristics in samples containing 20, 25, 30, 35 and 40% water while the amounts of added Baekbokryung powder were fixed at 3% and 5%, respectively, as based on the sensory panel results. For the color characteristics of the samples, lightness(L), redness(a) and yellowness(b) values increased in proportion to the added amount of water regardless of the Baekbokryung level. However, the ${\Delta}E$ values of the samples increased with storage time along with the darkening of their surfaces. The samples with high moisture contents, such as the 35 and 40% treatments, maintained a relatively softer texture during 24 hr of storage as compared to the other samples. Also noted was an initial slow increase in hardness up to 12 hr of storage, and then accelerated hardening until 24 hours of storage. Throughout the storage period, th 30% treatment received low scores: the 40% treatment was especially disliked in terms of mashing of the product due to the excess water. Overall, for a soft and moderately chewy product, the optimum Baekbokryung powder and moisture level for Jeolpyuns were suggested as 3 to 5% ranges and 35% respectively. Ultimately, the results of this research will contribute to the possible commercialization of a Jeolpyuns product that contains added Baekbokryung.

THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES (1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과)

  • Baek, Shin-Young;Cho, Young-Gon;Song, Byeong-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.428-434
    • /
    • 2008
  • The purpose of this study was to compare the microtensile bond strength in Class I cavities associated with different light curing modes of same light energy density. Occlusal enamel was removed to expose a flat dentin surface and twenty box-shaped Class I cavities were prepared in dentin. Single Bond (3M Dental product) was applied and Z 250 was inserted using bulk technique. The composite was light-cured using one of four techniques, pulse delay (PD group), soft-start (SS group), pulse cure (PC group) and standard continuous cure (CC group). The light-curing unit capable of adjusting time and intensity (VIP, Bisco Dental product) was selected and the light energy density for all curing modes was fixed at $16J/cm^2$. After storage for 24 hours, specimens were sectioned into beams with a rectangular cross-sectional area of approximately $1mm^2$ Microtensile bond strength $({\mu}TBS)$ test was per- formed using a univel·sal testing machine (EZ Test, Shimadzu Co.). The results were analyzed using oneway ANOVA and Tukey's test at significance level 0.05. The ${\mu}TBS$ of PD group and SS group was higher than that of PC group and CC group. Within the limitations of this in vitro study, modification of curing modes such as pulse delay and soft start polymerization can improve resin/dentin bond strength in Class I cavities by controlling polymerization velocity of composite resin.