• Title/Summary/Keyword: soft error

Search Result 362, Processing Time 0.026 seconds

New Decoding Scheme for LDPC Codes Based on Simple Product Code Structure

  • Shin, Beomkyu;Hong, Seokbeom;Park, Hosung;No, Jong-Seon;Shin, Dong-Joon
    • Journal of Communications and Networks
    • /
    • v.17 no.4
    • /
    • pp.351-361
    • /
    • 2015
  • In this paper, a new decoding scheme is proposed to improve the error correcting performance of low-density parity-check (LDPC) codes in high signal-to-noise ratio (SNR) region by using post-processing. It behaves as follows: First, a conventional LDPC decoding is applied to received LDPC codewords one by one. Then, we count the number of word errors in a predetermined number of decoded codewords. If there is no word error, nothing needs to be done and we can move to the next group of codewords with no delay. Otherwise, we perform a proper post-processing which produces a new soft-valued codeword (this will be fully explained in the main body of this paper) and then apply the conventional LDPC decoding to it again to recover the unsuccessfully decoded codewords. For the proposed decoding scheme, we adopt a simple product code structure which contains LDPC codes and simple algebraic codes as its horizontal and vertical codes, respectively. The decoding capability of the proposed decoding scheme is defined and analyzed using the parity-check matrices of vertical codes and, especially, the combined-decodability is derived for the case of single parity-check (SPC) codes and Hamming codes used as vertical codes. It is also shown that the proposed decoding scheme achieves much better error correcting capability in high SNR region with little additional decoding complexity, compared with the conventional LDPC decoding scheme.

Predictive model for the shear strength of concrete beams reinforced with longitudinal FRP bars

  • Alzabeebee, Saif;Dhahir, Moahmmed K.;Keawsawasvong, Suraparb
    • Structural Engineering and Mechanics
    • /
    • v.84 no.2
    • /
    • pp.143-154
    • /
    • 2022
  • Corrosion of steel reinforcement is considered as the main cause of concrete structures deterioration, especially those under humid environmental conditions. Hence, fiber reinforced polymer (FRP) bars are being increasingly used as a replacement for conventional steel owing to their non-corrodible characteristics. However, predicting the shear strength of beams reinforced with FRP bars still challenging due to the lack of robust shear theory. Thus, this paper aims to develop an explicit data driven based model to predict the shear strength of FRP reinforced beams using multi-objective evolutionary polynomial regression analysis (MOGA-EPR) as data driven models learn the behavior from the input data without the need to employee a theory that aid the derivation, and thus they have an enhanced accuracy. This study also evaluates the accuracy of predictive models of shear strength of FRP reinforced concrete beams employed by different design codes by calculating and comparing the values of the mean absolute error (MAE), root mean square error (RMSE), mean (𝜇), standard deviation of the mean (𝜎), coefficient of determination (R2), and percentage of prediction within error range of ±20% (a20-index). Experimental database has been developed and employed in the model learning, validation, and accuracy examination. The statistical analysis illustrated the robustness of the developed model with MAE, RMSE, 𝜇, 𝜎, R2, and a20-index of 14.6, 20.8, 1.05, 0.27, 0.85, and 0.61, respectively for training data and 10.4, 14.1, 0.98, 0.25, 0.94, and 0.60, respectively for validation data. Furthermore, the developed model achieved much better predictions than the standard predictive models as it scored lower MAE, RMSE, and 𝜎, and higher R2 and a20-index. The new model can be used in future with confidence in optimized designs as its accuracy is higher than standard predictive models.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.

MRI Evaluation for the Histologic Components of Soft-tissue Tumors: Comparison of MEDIC and Fast SE T2-weighted Imaging (연조직종양의 조직 성분 평가를 위한 자기공명영상: MEDIC 과 지방억제 T2 영상의 비교)

  • Moon, Tae-Yong;Lee, In-Sook;Lee, Jun-Woo;Choi, Kyung-Un;Kim, Jeung-Il;Kim, E. Edmund
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Purpose : To compare Multi Echo Data Image Combination (MEDIC) and fast SE T2-weighted images with fat saturation (T2FS) to suggest more accurate evaluation of the histologic components of soft-tissue tumors. Materials and Methods : The experimental group included 25 histologic tissues (5 vascular, 4 neural, 4 fibrous, 4 hypercellular, 2 hemorrhagic necroses, 2 cystic, 2 lipoid, 1 myxoid stroma, and 1 thrombus) in 10 patients who had pathologically confirmed schwannoma (n = 3), hemangioma (n = 2), lipoma (n = 1), angiokeratoma (n = 1), synovial sarcoma (n = 1), liposarcoma (n = 1), and malignant fibrous histiocytoma (n = 1). The inhomogeneity values were measured using the standard deviation value (SD) divided by the mean value as SD presents an error amount similar to that of imaging heterogeneity. Results : The inhomogeneity values of 25 histologic components were lower on MEDIC than those on T2FS (p < .001). Conclusion : We conclude that MEDIC is more accurate than T2FS for evaluating the tissue components of soft-tissue tumors using digitalized data because MEDIC images have far lower inhomogeneity.

  • PDF

Central Corneal Thickness of Normal Eyes and Contact Lens-wearing Eyes Aged in their 20s and 30s (20․30대 정상안과 콘택트렌즈 착용안의 각막 중심 두께)

  • Park, Mijung;Park, Kyeong Sun;Ahn, So Yeoun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.29-35
    • /
    • 2007
  • This study was conducted to measure the central corneal thickness(CTT) changes associated with kinds of wearing contact lens. The CCT was measured using ultrasonic pachymeter in three hundred four subjects in their 20s and 30s. Although the CCT of Group 1 who had never worn any kinds of contact lens had no differences between left and right eye as well as between genders, the CCT tended to become thinner depending on the increment in refractive error. In Group 2 wearing only soft contact lens, the CCT was thinner depending on wearing period, and subjects wearing for more than 10 years had significantly thin CCT comparing with subjects wearing for less than 4 years. There was no significant difference in the CCT between Group 3 wearing only RGP lens and Group 2 for less than 4 years. Furthermore, when comparing the CCT between the Group 2 and Group 4 changing to RGP lens after wearing soft contact lens, there was no statistically significant change in the CCT. However, the CCT was significantly thinner in Group 5 changing to soft contact lens after wearing PMMA(polymethyl methacrylate) hard lens compared with Group 2.

  • PDF

Classical Tamil Speech Enhancement with Modified Threshold Function using Wavelets

  • Indra., J;Kasthuri., N;Navaneetha Krishnan., S
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1793-1801
    • /
    • 2016
  • Speech enhancement is a challenging problem due to the diversity of noise sources and their effects in different applications. The goal of speech enhancement is to improve the quality and intelligibility of speech by reducing noise. Many research works in speech enhancement have been accomplished in English and other European Languages. There has been limited or no such works or efforts in the past in the context of Tamil speech enhancement in the literature. The aim of the proposed method is to reduce the background noise present in the Tamil speech signal by using wavelets. New modified thresholding function is introduced. The proposed method is evaluated on several speakers and under various noise conditions including White Gaussian noise, Babble noise and Car noise. The Signal to Noise Ratio (SNR), Mean Square Error (MSE) and Mean Opinion Score (MOS) results show that the proposed thresholding function improves the speech enhancement compared to the conventional hard and soft thresholding methods.

A Comparative Study of Branch Metric Calculator in QAM-TCM Decoder (QAM-TCM 복호기의 가지척도계산방식 비교 연구)

  • 김진우;최시연;강병희;오길남;김덕현
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.249-252
    • /
    • 2001
  • TCM(Trellis Coded Modulation) has soft decision scheme so that BM(Branch Metric) calculates the ED(Euclidean Distance) between the received signal and each code words in signal space. For computing the ED, square and square root computations increase the hardware complexity. Some simplified method is known for convolutional codes with QPSK(Quadrature Phase Shift Keying), PSK(Phase Shift Keying) modulation. But it is not acceptable for QAM (Quadrature Amplitude Modulation)-TCM scheme. In this paper, we suggest that two modified BM computation methods, which is applicable for QAM-TCM. By comparative study, we also assessed two proposed method in the case of hardware complexity and BER (Bit Error Rate) performance.

  • PDF

Control of Defect Produced in a Retrograde Triple Well Using MeV Ion Implantation (MeV 이온주입에 의한 Retrograde Triple-well 형성시 발생하는 결합제어)

  • 정희석;고무순;김대영;류한권;노재상
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.17-20
    • /
    • 2000
  • This study is about a retrograde triple well employed in the Cell tr. of next DRAM and flash memory. triple well structure is formed deep n-well under the light p-well using MeV ion implantation. MeV P implanted deep n-well was observed to show greatly improved characteristics of electrical isolation and soft error. Junction leakage current, however, showed a critical behavior as a function of implantation and annealing conditions. {311} defects were observed to be responsible for the leakage current. {311} defects were generated near the R$\sub$p/ (projected range) region and grown upward to the surface during annealing. This is study on the defect behavior in device region as a function of implantation and annealing conditions.

  • PDF

A Development of the Algorithms for Automation of Slicing Machine with GUI Interface (GUI를 이용한 슬라이싱 머신의 자동화 알고리즘 개발)

  • Kim, Hyoung-Tae;Yang, Hae-Jeong;Song, Chang-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.85-93
    • /
    • 1999
  • In this study, PC-based slicing machine and driving software were constructed for the purpose of automation of semi-conductor cutting process. The biggest feature of software is variation of parameter and include data base, signal monitoring, error report, corresponding action or automatic motion planing. Parameters were drawn and algorithms were developed to make software by GUI interface. The cutting experiment was done for sampled wafer to see the effectiveness of the soft automation. From the experimented and implemented results, it is shown that parameters for automation of slicing process could be drawn, then its algorithms constructed. It could be considered what is the merit of this slicing machine by comparing the PC-based and the NC-based.

  • PDF

Limited Constellation List Sphere Decoding (격자 제한 리스트 스피어 디코딩)

  • Jeon, Myeong-Woon;Lee, Jung-Woo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.1-3
    • /
    • 2010
  • 스피어 복호 알고리즘 (sphere decoding algorithm)은 다중 입출력 (MIMO) 통신 시스템에서 사용되는 복호기중 최대 우도 복호기 (Maximum Likelihood Detector)와 비슷한 BER(bit error rate)성능을 가지고 복잡도를 줄일수 있어서 최근 많이 연구되어 왔다. 이때 공간 다중화와 채널 부호의 연접시스템에서 연판정 정보(Soft output information) 를 스피어 복호 알고리즘을 통해 생성하기 위한 방법으로 리스트 스피어 복호 알고리즘 (List Sphere Decoding)이 알려져있다. 기존 리스트 스피어 디코딩 알고리즘은 리스트를 반지름을 업데이트 하지 않으므로 탐색시 복잡도가 매우 높다는것이 문제가 되므로, 차원별로 최적해의 가능성이 높은 격자 주변으로 검색을 제한하여 복잡도를 줄이는 알고리즘을 제안하고 성능과 복잡도를 실험한다.

  • PDF