• Title/Summary/Keyword: smoke density

Search Result 181, Processing Time 0.035 seconds

A Study on Fire Features of Double-Skin Facade Structure by Using Fire Simulation (FDS) (화재 시뮬레이션(FDS)을 이용한 이중외피 구조의 화재 특성에 관한 연구)

  • Gu, Seon-Hwan;Kim, Hyun-Ho;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • This study aims to address the fire characteristics of Double-skin facade using the Fire Dynamics Simulator (FDS). To end this, Double-skin facade was classified into the four structures, that is Box, Shaft-box, Corridor, Multistory, through PyroSim program which was based on FDS, and further each structure of fire characteristics were analyzed numerically as well as comparatively in the current study. This study also examined smoke movement, smoke density, smoke detectors, and visibility in order to closely identify the each structure of fire characteristics. The results of the study discovered that the Box structure did not significantly affect smoke which was rising in the other rooms, except for the fire room whereas the Corridor structure had positive effects on Double-skin facade horizontally. In addition, the Shaft-box structure showed the fastest vertical movement by means of the shaft, on the other hand, rising smoke influenced the other rooms as well. The Multistory structure along with rising smoke had a great impact on the other divided rooms in a vertical way.

Foaming Properties and Flame Retardancy of the Foams Based on NBR/GTR Compounds (니트릴고무/타이어고무분말(GTR)를 이용한 발포체의 발포 및 난연 특성에 관한 연구)

  • Moon, Sung-Chul;Jo, Byung-Wook;Choi, Jae-Kon
    • Elastomers and Composites
    • /
    • v.37 no.3
    • /
    • pp.159-169
    • /
    • 2002
  • The improvement of flame retardancy of the foams based on NBR/GTR compounds was conducted by formulating various materials i.e. NBR, GTR, inorganic and phosphorus containing flame retardants, foaming agent, cross-linking agent and activator. The foaming properties, morphology, smoke density and flame retardancy of the specimens were investigated using SEM, LOI tester, smoke density control system and cone calorimeter. The phosphorus containing flame retardant reduces heat release rate, increases the limiting oxygen index and a char formation. The inorganic flame retardant increases the limiting oxygen index and reduces heat release rate with an increased CO yield by char formation, and smoke suppressing effect. The formed char seemed to intercept the oxygen transport and heat transfer into the core area. When the composition ratios of the compounds of NBR/GTR were $100{\sim}80/0{\sim}20 wt.%$, and the ratios of the rubbers/flame retardants were $1/1.55{\sim}3.60 wt.%$, we could developed foams with low heat release rate, high limiting oxygen index($28.0{\sim}39.3$), closed or semi-closed cell of uniformity and reasonable expandability($225{\sim}250 %$).

Evacuation Simulation of High-Rise Building Fires Considering Temperature and Smoke (열화와 연기를 고려한 고층 건물 화재시의 대피 시뮬레이션)

  • Lee, Bum-Jong;Park, Jong-Seung;Rie, Dong-Ho
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.703-707
    • /
    • 2008
  • This paper proposes a method of design and implementation a simulation system in which humans can plan their evacuation paths in a high-rise building considering damages from high temperature and smoke in case of fire. Humans in evacuation search the nearest exit and follow a path to the exit. When humans are evacuating toward an exit, they are going to move with their highest speeds. However, many environmental factors prohibit their fast movements. In this paper, we calculate the evacuation speed of each human considering temperature damage and smoke damage. We restrict the number of humans that can be evacuated per second according to the actual size of the exit door. Experimental results showed that the evacuation speed is affected by the temperature condition and the smoke density.

  • PDF

A Study on Volatile Organic Compounds(VOC) in Environmental Tobacco Smoke(ETS) at Indoor Office Environments (실내사무환경에서의 환경성담배연기(ETS)중 일부 휘발성유기화합물(VOC)에 관한 연구)

  • 하권철
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.87-98
    • /
    • 2001
  • There has been increased interest in the health effects of the Environmental Tobacco Smoke(ETS) as a confirmed human carcinogen. It has been known to be extremely difficult to make an accurate assessment of exposure to ETS since it is consisted of a variety of components and there are a number of labile chemicals. Therefore, it is necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment to ETS in the field of environmental health. The purpose of this research is to evaluate the concentration of ETS using VOC in indoor office environments. The correlations and concentrations of benzene, RSP, 3-EP, nicotine that are indicators for ETS were investigate with smoking density, air change per hour(ventilation rate). Air samples were taken in smoking room(7 sites), smoking allowed office (3 sites), corridor outside smoking room(7 sites), non-smoking office (9 sites). The concentrations of benzene showed significant difference according to category of indoor office environments. The geometric mean concentration of benzene were 23.56 ${\mu}{\textrm}{m}$/㎥(range 4.80~192.90 ${\mu}{\textrm}{m}$/㎥) in smoking rooms. 6.16 ${\mu}{\textrm}{m}$/㎥ in smoking allowed offices, 1.32 ${\mu}{\textrm}{m}$/㎥ in the non-smoking offices respectively. The ratios of the concentration of benzene between outdoor air and smoking room, smoking allowed office, and non-smoking indicators concentrations, SD, and SI were 0.82(benzene and nicotine). 0.76(benzene and RSP), 0.60(benzene and SD), 0.76(benzene and SI). It is proposed that benzene is a good indicator for ETS.

  • PDF

Desalting of tobacco extract using electrodialysis

  • Ge, Shaolin;Li, Wei;Zhang, Zhao;Li, Chuanrun;Wang, Yaoming
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.341-353
    • /
    • 2016
  • Papermaking reconstituted tobacco is an important strategy for recycling the waste tobacco residues. To indentify the influences of the inorganic components on harmful components delivery in cigarette smoke, a self-made electrodialysis stack was assembled to desalt the tobacco extract. The influences of the applied current and extract content on the removal rate of the inorganic ions were investigated. Results indicated that the applied current was a dominant impact on the desalination performance. High currents lower than the limiting current density could accelerate the desalting efficiency but cause higher energy consumption. A current of 2 A, or current density of ${\sim}11mA{\cdot}cm^{-2}$, was an optimal choice by considering both the energy consumption and desalting efficiency. A 20% tobacco extract was an appropriate content for the electrodialysis process. More than 90% of inorganic ions could be removed under the optimum condition. The preliminary result indicated that removal of inorganic components was beneficial to decrease the harmful component delivery in cigarette smoke. Naturally, ED is an environmentally friendly and high-effective technology for desalting the tobacco extract.

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

The Study of Simulation for Reproduce Accidents of Narrow Dwelling Space (협소 거주공간 사고 재현을 위한 시뮬레이션 연구)

  • Lee, Changwoo;Choi, Beakyoul;Kim, Jinsung;Cho, Yongsun;Yoo, Juyoul
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.3
    • /
    • pp.210-218
    • /
    • 2016
  • In this study, the fire analysis program FDS and Pathfinder was used to analysis a simulated accidental fire of a narrow dwelling space as a test bed. The results showed that the evacuation time of the H form internal building structure was the fastest at 285 seconds. In addition, when the automatic sprinkler system functioned with the entrances closed, the temperature distribution was lower and the visible smoke density was reduced.

A Study on the Combustion Characteristic of Building Materials (건축용 내장재의 연소 특성에 관한 연구)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Kim, Jin-Pyo;Park, Jong-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.23-28
    • /
    • 2011
  • This paper studied combustion characteristics of the building materials such as polyurethane-foam, sponge type sound-absorbing materials and styrofoam. To estimate of the combustion characteristics, we carried out combustion experiment of the building materials. And then to evaluate the suitability of the building materials, we measured heat release rate(HRR) and smoke density(Ds) of polyurethane-foam, sponge type sound-absorbing materials and styrofoam using by a cone-calorimeter. From the combustion experimental results, the general type sound-absorbing materials (GSAM) and styrofoam were rapid burned simultaneously with ignition and the incombustibility type sound-absorbing materials(ISAM) and polyurethane-foam had all gone out simultaneously with ignition. Measured results of HRR and Ds were not satisfied KS F ISO 5660-1 and IMO FTP Code, from the results, the polyurethane-foam, the sponge type sound-absorbing material and the styrofoam were ill-suited for using building interior materials.

A Study on Combustion And Exhaust Emissions of Diesel Engine -For Gas Oil-Water Emulsified Fuel- (디젤 기관의 연소와 배출물에 관한 연구 -경유-물물의 유화연료 사용시-)

  • 조진호;김형섭;박정률
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.180-188
    • /
    • 1992
  • By means of the compatibility according to solving environmental pollution and energy problem due to the emissions of NOx and smoke from diesel engine this paper experimentally inspected the effect of using emulsified fuel, gas oil-water, for combustion characteristic, that is combustion pressure, pressure rise rate, heat generating rate, the period of ignition delay and specific fuel consumption, and CO, HC, NOx concentration and smoke density. When using emulsified fuel, as a water addition rate was increased, combustion pressure, pressure rise rate and heat generating rate was increased, the period of ignition delay was lengthening, the specific fuel consumption was some what increased in contrast to diesel fuel in low load, but deceased in high load region. And NOx concentration was decreased, CO concentration was increased in low load, but decreased in high load region, HC concentration was increased in contrast to diesel fuel in all region.

Some Considerations for Performance of D.I. Diesel Engine Using Auxiliary Fuel Such as Alcohol (알코올을 보조적으로 사용한 직접분사식 디젤기관의 성능에 관한 고찰)

  • 이형곤;방중철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.28-35
    • /
    • 2002
  • The objective of this paper is to quantitatively investigate the effects of alcohol mixture on the combustion improvement of main fuel in supplying alcohol to direct injection diesel engine by auxiliary injection method and blend method. If alcohol is supplied, engine performance greatly improves in high load range. In case of supplying ethanol, BSFC improves, the emission of smoke and NO decreases by delaying main fuel injection timing 5$\^{C}$A. The maximum delivery quantity of alcohol is limited to approximately 50% of total fuel delivery due to misfire and knocking. The limit quantity of main fuel injection that does not accompany misfire and the deterioration of BSFC was approximately 15∼18.5mg/st.