• 제목/요약/키워드: smart damping

검색결과 311건 처리시간 0.022초

스마트 최상층 면진시스템의 중약진지역 적용성 평가 (Investigation of Adaptability of Smart Top-Story Isolation System to Structures in Regions of Low-to-Moderate Seismicity)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.71-80
    • /
    • 2012
  • Because a smart isolation system cannot be used as a base isolation system for tall buildings, top-story or mid-story isolation systems are required. In this study, adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions in comparison with a passive top-story isolation system.

지능형 Hull구조물의 능동 진동제어 (Active Vibration Control of Smart Hull Structures)

  • 손정우;최승복;김흥수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.192-195
    • /
    • 2005
  • In this study, dynamic characteristics of an end-capped hull structure with surface bonded piezoelectric actuators are studied. Finite element modeling is used to obtain practical governing equation of motion and boundary conditions of smart hull structure. Modal analysis is conducted to investigate the dynamic characteristics of the hull structure. Piezoelectric actuators are attached where the maximum control performance can be obtained. Active controller based on Linear Quadratic Gaussian (LQG) theory is designed to suppress vibration of smart hull structure. It is observed that closed loop damping can be improved with suitable weighting factors in the developed LQG controller.

  • PDF

MFC 작동기를 이용한 Hull 구조물의 진동 저감 (Vibration Suppression of Hull Structure Using MFC Actuators)

  • 손정우;김흥수;최승복
    • 한국소음진동공학회논문집
    • /
    • 제17권7호
    • /
    • pp.587-595
    • /
    • 2007
  • Performance evaluation of advanced piezoelectric composite actuator is conducted with its application of structural vibration control. Characteristics of MFC(macro fiber composite) actuator are investigated by comparing traditional piezoceramic patch actuator. Finite element modeling is used to obtain equations of motion and boundary effects of smart hull structure with MFC actuator. Dynamic characteristics of the smart hull structure are studied through modal analysis and experimental investigation. LQG control algorithm is employed to investigate active damping of hull structure. It is observed that vibration of hull structure is suppressed effectively by the MFC actuators.

MFC 작동기를 이용한 Hull 구조물의 진동 저감 (Vibration Suppression of Hull Structure Using MFC Actuators)

  • 손정우;김흥수;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1119-1124
    • /
    • 2007
  • Performance evaluation of advanced piezoelectric composite actuator is conducted with its application of structural vibration control. Characteristics of MFC (macro fiber composite) actuator are investigated by comparing traditional piezoceramic patch actuator. Finite element modeling is used to obtain equations of motion and boundary effects of smart hull structure with MFC actuator. Dynamic characteristics of the smart hull structure are studied through modal analysis and experimental investigation. LQG control algorithm is employed to investigate active damping of hull structure. It is observed that vibration of hull structure is suppressed effectively by the MFC actuators.

  • PDF

지능형 완충기의 특성 해석 (Performance Analysis of Smart Impact Damper)

  • 이덕영;황우석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.323-327
    • /
    • 2001
  • Electrorheological(ER) and magnetorheological(MR) fluids have a unique ability to increase the dynamic yield stress of the fluid substantially when electric or magnetic field is applied. Controllable fluids such as ER and MR fluids have received considerable attention as several components of engineering devices. One of them is a smart impact damper using ER/MR fluids. Impact damper system can be used in the joint mechanism of railroad vehicle, protection equipment of elevator's drop, and launch equipment of aircraft. This paper presents the results of an analytical study of the performance of a smart impact damper to suppress vibration during impact excitation. The damping capabilities of MR impact damper for variable applied current are analyzed using Bingham model under sudden impact load.

  • PDF

Analytical Development of a Robust Controller for Smart Structural Systems

  • Park Chul Hue;Hong Seong Il;Park Hyun Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1138-1147
    • /
    • 2005
  • This paper aims at demonstrating the feasibility of active control of beams with a multiobjective state-feedback control technique. The multiobjective state-feedback controller is de­signed on a linear matrix inequality (LMI) approach for the multiobjective synthesis. The design objectives are to achieve a mix of Hoo performance and H2 performance satisfying constraints on the closed-loop pole locations in the face of model uncertainties. The controller is also designed to reject the effects of the noise and external of disturbances. For the theoretical analysis, the governing equation of motion is derived by Hamilton's principle to describe the dynamics of a smart structural system. Numerical examples are presented to demonstrate the effectiveness of the integrated robust controller in damping out the multiple vibration modes of the piezo/beam system.

상부공격 지능탄의 회전각 적응제어 기법 연구 (A Study on the Adaptive Roll Control Scheme for the Top Attack Smart Projectile)

  • 홍종태;정수경;최상경
    • 한국군사과학기술학회지
    • /
    • 제3권2호
    • /
    • pp.61-70
    • /
    • 2000
  • An Adaptive Positive Position Feedback method is presented for controlling the roll of the supersonic smart projectile. The proposed strategy combines the attractive attributes of Positive Position Feedback(PPF) of Goh and Caughey, and Lyapunov stability theorem. The parameters of Adaptive-PFF controller are adjusted in an adaptive mauler in order to follow the performance of an optimal reference model. In this way, optimal damping and zero steady-state errors can be achieved even in the presence of uncertain or changing plant parameters. The performance obtained with the Adaptive-PPF algorithm is compared with conventional PPF control algorithm. The results obtained emphasize the potential of Adaptive-PPF algorithm as an efficient means for controlling plants such as supersonic flight systems with uncertainties in real time.

  • PDF

압전세라믹을 이용한 지능 복합적층판의 강제진동의 능동제어 (Active Control of Forced Vibrations in Smart Laminated Composite Plates Using Piezoceramics)

  • 강영규;구근회;박현철
    • 한국소음진동공학회논문집
    • /
    • 제11권6호
    • /
    • pp.193-199
    • /
    • 2001
  • Active control of forced vibration of the cantilevered laminated composite plates using collocated piezoceramic sensor/actuator is analyzed numerically and verified experimentally for various fiber orientations. Impact on the stiffness and the damping properties is studied by varying stacking sequence of [$\theta$$_{4}$O$_{2}$90$_{2}$]s for the laminated composite plate. For the forced vibration control, the plate is excited by one pair of collocated PZT exciters in resonance and its vibrational response is suppressed by the other collocated PZT sensor/actuator using direct negative velocity feedback. It is shown that the active control of forced vibration is more effective for the smart laminated plate with higher modal damped stiffness(2ζ$\omega$/aup 2/) .

  • PDF

MOGA-Based Structural Design Method for Diagrid Structural Control System Subjected to Wind and Earthquake Loads

  • Kim, Hyun-Su;Kang, Joo-Won
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1598-1606
    • /
    • 2018
  • An integrated optimal structural design method for a diagrid structure and control device was developed. A multi-objective genetic algorithm was used and a 60-story diagrid building structure was developed as an example structure. Artificial wind and earthquake loads were generated to assess the wind-induced and seismic responses. A smart tuned mass damper (TMD) was used as a structural control system and an MR (magnetorheological) damper was employed to develop a smart TMD (STMD). The multi-objective genetic algorithm used five objectives including a reduction of the dynamic responses, additional stiffness and damping, mass of STMD, capacity of the MR damper for the integrated optimization of a diagrid structure and a STMD. From the proposed method, integrated optimal designs for the diagrid structure and STMD were obtained. The numerical simulation also showed that the STMD provided good control performance for reducing the wind-induced and seismic responses of a tall diagrid building structure.

초음파 펄스 분석을 통한 SBR계 폴리머 혼입 모르타르의 폴리머 혼입률에 따른 진 동감쇠비 성능 평가 (Vibration Damping Ratio Performance Evaluation According to the Polymer Mixing Rate of SBR-based Polymer Modified Mortar through Ultrasonic Pulse Analysis)

  • 정민구;장종민;이한승
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.543-551
    • /
    • 2022
  • 폴리머 혼입 모르타르를 대상으로 폴리머 혼입률에 따른 실험체의 역학적 성능 및 진동감쇠비 성능 평가를 실시하였다. 폴리머로서는 Styrene Butadiene Rubber(SBR) 고형분이 약 49~51%인 액상형 폴리머를 사용하였으며, 5%씩 액상 폴리머 함량을 증가시켰으며, 고형분 기준으로 약 2.5%씩 증가하였다. 실험체는 40×40×160(mm)로써 경화 후에 압축강도, 휨강도, 초음파펄스법을 통해 진동감쇠비를 측정하였다. 그 결과, 폴리머 혼입률이 증가함에 따라 압축강도는 감소하나 휨강도는 증가하였으며, 진동감쇠비는 폴리머 고형분 2.5% 첨가에서 11% 증가, 폴리머 고형분 5%에서 28% 증가, 폴리머 고형분 7.5%에서 33% 증가, 폴리머 고형분 10%에서 72%로 급격히 증가하여 모르타르의 진동 저감을 위하여 폴리머의 혼입이 매우 유효함을 알 수 있었다. 또한, SEM 및 SEM-EDS 분석을 통하여, 폴리머 혼입에 의한 진동 저감의 원인은 골재의 천이대 및 내부 공극에 형성된 폴리머 막이 모르타르의 진동을 내부에서 완충시킨 것으로 판단된다. 이를 종합하면, 본 연구의 범위에서 모르타르의 진동 저감을 위한 적정 폴리머 혼입 비율은 고형분 기준 약 7.5% 정도로 판단된다.