• Title/Summary/Keyword: sludge solubilization

Search Result 90, Processing Time 0.029 seconds

Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization (펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.16-23
    • /
    • 2018
  • Alternative technologies for sludge treatment and disposal need to be developed urgently because the amount of produced production has increased continuously. In this study, Pulsed Electric Fields (PEF) technique was applied for sludge solubilization and the performance was evaluated. The PEF equipped with electrodes coated by epoxy resin and teflon was inducted to the activated sludge suspension, and the effect of the coating materials on the solubilization was determined. In addition, the effect of the applied voltage on the solubilization yield was investigated as the applied voltage was increased from 6 to 12 and 15 kV. Sludge solubilization was not observed when the epoxy-coated electrode was used for PEF induction regardless of the applied voltage. However, sludge solubilization occurred when 12 and 15 kV were applied to the teflon-coated electrodes. The MLSS decreased to 9%, and the soluble-COD increased to 496% when the applied voltage was 15 kV. But sludge solubilization did not happen under 6 kV condition. The corona discharge was observed at applied voltages of 12 and 15 kV, (Ed- sorry but I cannot understand the following highlight) but if 6 kV, strongly indicating that the corona discharge make the sludge solubilized, which suggests that the critical voltage for sludge solubilization lies between 6 and 12 kV. Consequently, proper selection of electrode-coating materials and the applied voltage of PEF could lead to sludge solubilization by corona discharge.

Study on Characteristics of Solubilization for Sewage Sludge Using Electronic Field and Ultrasonification (전기장과 초음파를 이용한 하수슬러지의 가용화 특성 연구)

  • Seo, Jang-Won;Han, Ji-Sun;Ahn, Chang-Min;Min, Dong-Hee;Yoo, Yeon-Sun;Yoon, Soon-Uk;Lee, Jong-Gyu;Lee, Jong-Yeon;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.636-643
    • /
    • 2011
  • Sludge solubilization using sonification has been increasingly used for sludge volume reduction along with enhancing digestion efficiency during anaerobic biogas production. In this study, either electric field or ultrasonification or in combination with were investigated using three types of sludge (return, excess and mixed at G sewage treatment facility) for the most efficient solubilization. As a the closed loop, 200 L of sludge was continuously passing through the solubilization system at an average flow rate of $0.7m^3/h$, which is equivalent to 3.5 times treated per hour for up to 84 times (24 h). Only implying electric field showed no variation for sCOD/tCOD before and after treatment on sludge solubilization regardless of types of sludge. However, employing the ultrasonic or combined system could both increasingly solubilize sludge with regard to the number of passing-through, which more enhanced by the combined. In addition, VSS/TSS was lowered to in the range of 2 and 6% while its particle size, diameter (0.9) and diameter (0.5) were more minimized than that of raw sludge. For return sludge, ultrasonification was more efficiently facilitated for solubilization, whereas electric field-ultrasonification was more preferably applied for excess and mixed sludge. It is concluded that depending on types of sludge, solubilization system must be selectively applied for the most efficient break-up of them.

Effect of Temperature-increase Rate and Terminal Temperature on the Solubilization of Sewage Sludge using Microwave Irradiation

  • Park, Woon-Ji;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.48-52
    • /
    • 2009
  • Solubilization of sewage sludge creates favorable conditions for anaerobic microorganisms to produce biogas. In this paper, we quantify the effect of heating pretreatment on the degree of solubilization of sewage sludge. The pretreatment process was carried out using a lab-scale industrial microwave unit (2450 MHz frequency). Response surface analysis was applied to determine the combination of temperature-increase rate (ramp rate) (2.9 to 17.1 ${^{\circ}C}$/min) and terminal temperature (52 to 108${^{\circ}C}$). Both ramp rate and temperature significantly affected the solubilization degree of sludge. Within the design boundaries, the conditions predicted to maximize the solubilization degree of 15.8% were determined to be 2.9 ${^{\circ}C}$/min and 104${^{\circ}C}$.

Reduction of sludge production and recycled nutrients loading by high-rate aerobic digestion(CaviTec II) with inorganic sludge separation and sludge solubilization (무기슬러지 분리와 슬러지 가용화를 적용한 고효율 호기성 소화기술(CaviTec II)에 의한 슬러지 감량 및 반수류 부하 저감)

  • Lee, Dong-Woo;Bae, Kang-Hyeong;Cho, Kun-Sang;Kim, Sung-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.411-417
    • /
    • 2014
  • The performance of the new aerobic digestion system combined with inorganic sludge separation unit and sludge solubilization unit, CaviTec II, is evaluated. Anaerobic digester effluent sludge is used for feed sludge of CaviTec II system. By addition of CaviTec II, the amount of cake generated is reduced by 27%, and the soluble nitrogen is reduced by 92%.

Enhancement of Anaerobic Biodegradability using the Solubilized Sludge by the Cavitation process (Cavitation에 의해 가용화된 슬러지의 혐기성 생분해도 향상에 관한 연구)

  • Kim, Dongha;Lee, Jaegyu;Jung, Euitaek;Jeong, Hoyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2014
  • In order to investigate the effective pretreatment methods in WAS(=waste activated sludge) solubilization, the values of SCOD yield per unit SS (SCOD/gSS.hr) were compared. After the hydrodynamic cavitation with pH of 12.5, SCOD increased to 7800 mg/L, SS decreased to 45 % and the solubilization rate was 29 %. Combination of alkality (pH 12.5) and the cavitation seems to be the optimal condition for sludge solubilization. After the cavitational pretreatment, efficiencies of anaerobic digestion of the unfiltered sludge(the control), raw sludge and pretreated sludge were evaluated with BMP(=biochemical methane potential) tests. For evaluation of the biodegradability characteristics of pretreated sewage sludge, the methane production has been measured for 6 months. The methane production of pretreated sludge increased 1.4 times than that of untreated sludge. The result indicates that the cavitationally pretreated sludge was a better biodegradability substrate in anaerobic condition compared to raw sludge. It is obvious that cavitational pretreatment could enhance not only solubilization but also biodegradability of WAS. In conclusion, cavitational pretreatment of WAS to convert the particulate into soluble portion was shown to be effective in enhancing the digestibility of the WAS.

Solubilization of Sewage Sludge by Microwave Pretreatment and Elutriated Acid Fermentation (Microwave를 이용한 하수슬러지의 전처리 특성 및 회분식 세정산발효를 이용한 슬러지 가용화)

  • Lee, Won-Sic;Hong, Seung-Mo;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1130-1136
    • /
    • 2006
  • This work elucidates the effects of pretreatment of the sewage sludge from wastewater treatment plant by microwave irradiation on elutriated acid fermentation. These experiments typically fell into two process; pretreatment as microwave irradiation and elutriated acid fermentation for hydrolysis and acidification as main process of primary sludge. The results of maximum solubilization rate of B, D primary and secondary sludge were 0.042, 0.086 and 0.15 gSCODprod./gICODin and the optimum irradiation time of microwave on 2,450 MHz and 900 W were 5 min. for primary sludge and 7 min. for secondary sludge. From batch tests on elutriated acid fermentation that was used the pretreated primary sludge as microwave, the optimum pH and HRT (hydraulic retention time) were 7 and 5 days at $35^{\circ}C$ condition.

Assessment of Sludge Solubilization by Aeration and Zero-valent Iron As a Pre-treatment for Anaerobic Digestion (공기주입과 영가철을 이용한 하수슬러지 가용화 연구)

  • Kim, Yong-Jun;Park, Jin-Kyu;Tameda, Kazuo;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.53-61
    • /
    • 2016
  • The reaction of zero-valent iron (ZVI) with oxygen can produce reactive oxidants capable of oxidizing organic compounds. Thus, the aim of this study was to investigate the effect of pre-treatment on sludge solubilization by ZVI and aeration. The results demonstrated that the aeration pre-treatment with ZVI method was more effective than the only aeration for improving sludge solubilization, indicating that ZVI increased the extent of sludge solubilization. In addition, removal rate of $NH_3-N$ by ZVI and aeration was found to be 34%, while only aeration was 24%. Thus, ZVI and aeration can be employed as an efficient pre-treatment option to achieve higher sludge solubilization and decrease the toxic effect of $NH_3-N$ for sludge digestion.

A study for Solubilization and Bioavailability of Sewage Sludge Using the Complex Pre-treatment (복합 전처리를 통한 하수슬러지의 가용화 및 생물학적 유용성에 관한 연구)

  • Kang, Jung-Hyun;Lee, Hee-Soo;Lee, Tae-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2011
  • In this study, anaerobic biological decomposition were attempted after solubilization treatment of sewage sludge with the complex pre-treatment (acid/base treatment with ultrasonic radiation). Solubilization ratios were compared for ultrasonic treatment at acid or base condition. Solubilization effect of the complex pre-treatment was more effective at higher pH. Biological decomposition of complex pre-treated sludge was faster than non treated (raw) sludge, showing 10 times higher total gas production. Biological digestion of the sludge shows more biogas production. B/A ratio. which indicates hydrogen production potential, was 50% higher with complex pre-treated sludge than raw sludge but lactic acid or propionic acid were also detected during anaerobic decomposition process.

Characteristics of Anaerobic Methane Production by Ultrasonic Treatment of Excess Sludge (잉여슬러지의 초음파 처리에 의한 혐기성 소화에서의 메탄생성 특성 연구)

  • Lee, Jonghak;Jeong, Tae-Young;Roh, Hyun-Seog;Kim, Dongjin
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.810-815
    • /
    • 2010
  • Ultrasonic sludge pre-treatment has been studied to enhance the performance of anaerobic digestion by increasing sludge hydrolysis which is regarded as the rate-limiting-step of anaerobic digestion. In this study, the effect of ultrasonic pre-treatment on sludge hydrolysis (solubilization) and methane production was investigated. Sludge solubilization efficiency increased with ultrasonic energy input. However, it is uneconomical to apply more than 720 kJ/L as the solubilization efficiency per energy input declines afterwards. Volatile fatty acids concentration increased after the ultrasonic sludge hydrolysis. Anaerobic batch digestion showed that methane volume reached 64.7 and 84.5 mL after 18 days of incubation with the control sludge and ultrasonically hydrolyzed sludge, respectively. Methane production potential, maximum methane production rate, and the lag time of modified Gompertz equation were changed from 70 mL, 6.4 mL/day, and 1.2 days to 89 mL, 9.6 mL/day, and 0.5 day, respectively, after the ultrasonic sludge treatment. The results proved that ultrasonic pre-treatment contributed significantly not only for the methane production but also for the reduction of anaerobic digestion time which is critical for the performance of anaerobic sludge digestion.

A Study on the Thermal Solubilization Characteristics of Highly Thickened Excess Sludge in Municipal Wastewater Treatment Plant (하수처리장에서 발생하는 고농축 잉여슬러지의 열적가용화 특성에 관한 연구)

  • Kim, Eunhyuk;Park, Myoung Soo;Koo, Seulki
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.5-13
    • /
    • 2022
  • The current environmental problem is that environmental pollution is accelerating due to the generation of large amounts of waste and indiscriminate consumption of energy. Fossil fuels, a representative energy production fuel, are burned in the process of producing energy, generating a large amount of greenhouse gases and eventually causing climate change. In addition, the amount of waste generated worldwide is continuously increasing, and environmental pollution is occurring in the process of waste treatment. One of the methods for simultaneously solving these problems is the energy recovery from and reduction of organic wastes. Sewage sludge generated in sewage treatment plants has been treated in various ways since ocean disposal was completely prohibited, but the amount generated has been continuously increasing. Since the sewage sludge contains a large amount of organic materials, it is desirable to recover energy from the sewage sludge and reduce the final discharged waste through anaerobic digestion. However, most of the excess sludge is a mass of microorganisms used in sewage treatment, and in order for the excess sludge to be anaerobically digested, the cell walls of the microorganisms must be destroyed first, but it takes a lot of time to destroy the cell walls, so high rates of biogas production and waste reduction cannot be achieved only by anaerobic digestion. Therefore, the pre-treatment process of solubilizing excess sludge is required, and the thermal solubilization process is verified to be the most efficient among various solubilization methods, and high rates of biogas production and waste reduction can be achieved by anaerobic digestion after destroying cell walls the thermal solubilization process. In this study, when pretreating TS 10% thickened excess sludge through a thermal solubilization system, a study was conducted on solubilization characteristics according to retention time and operating temperature variables. The experimental variables for the retention time of the thermal solubilization system were 30 minutes, 60 minutes, 90 minutes, and 120 minutes, respectively, while the operating temperature was fixed at 160℃. The soulbilization rates calculated through TCOD and SCOD derived from the experimental results increased in the order of 12.11%, 20.52%, 28.62%, and 31.40%, respectively. And the variables according to operating temperature were 120℃, 140℃, 160℃, 180℃, and 200℃, respectively, while the operating retention time was fixed at 60 minutes. And the solubilization rates increased in the order of 7.14%, 14.52%, 20.52%, 40.72%, and 57.85%, respectively. In addition, TS, VS, T-N, T-P, NH4+-N, and VFAs were analyzed to evaluate thermal solubilization characteristics of thickened excess sludge. As a result, in order to obtain 30% or more solubilization rate through thermal solubilization of TS 10% thickened excess sludge, 120 minutes of retention time is required when the operating temperature is fixed to 160℃, and 170℃ or more of operating temperature is needed when the operating time is fixed to 60 minutes.